Search results for "detector"
showing 10 items of 3491 documents
Construction, assembly and tests of the ATLAS electromagnetic barrel calorimeter
2006
The construction and assembly of the two half barrels of the ATLAS central electromagnetic calorimeter and their insertion into the barrel cryostat are described. The results of the qualification tests of the calorimeter before installation in the LHC ATLAS pit are given.
Status of the EDELWEISS experiment
1999
The Edelweiss Dark Matter Experiment is installed in the Modane Underground Laboratory since 1994. In 1997 the first detector of a 70 g heat and ionization Ge low-temperature detector built by the collaboration showed its discrimination capabilities. During the last two years the installation was upgraded, and a new generation of 70 g Ge detectors is operational. The detector environment is drastically controlled to avoid radioactive contamination. A test run with two new 70 g detectors shows a reduction by a factor of ten in the background level before 7-ray rejection which is now around 2 events/kg/keV/day. Three 320 g Ge cryogenic detectors have been constructed and are now being tested …
The focal plane assembly for the Athena X-ray Integral Field Unit instrument
2016
This paper summarizes a preliminary design concept for the focal plane assembly of the X-ray Integral Field Unit on the Athena spacecraft, an imaging microcalorimeter that will enable high spectral resolution imaging and point-source spectroscopy. The instrument's sensor array will be a ~ 3840-pixel transition edge sensor (TES) microcalorimeter array, with a frequency domain multiplexed SQUID readout system allowing this large-format sensor array to be operated within the thermal constraints of the instrument's cryogenic system. A second TES detector will be operated in close proximity to the sensor array to detect cosmic rays and secondary particles passing through the sensor array for off…
Thermal Filters for the ATHENA X-IFU: Ongoing Activities Toward the Conceptual Design
2016
ATHENA is the L2 mission selected by ESA to pursue the science theme “Hot and Energetic Universe.” One of the two focal plane instruments is the X-ray Integral Field Unit, an array of TES microcalorimeters operated at T $$<$$ 100 mK. To allow the X-ray photons focused by the telescope to reach the detector, windows have to be opened on the cryostat thermal shields. X-ray transparent filters need to be mounted on these open windows to attenuate the IR radiation from warm surfaces, to attenuate RF electromagnetic interferences on TES sensors and SQUID electronics, and to protect the detector from contamination. This paper reviews the ongoing activities driving the design of the X-IFU thermal …
An improved goniometer head for high-temperature single-crystal X-ray diffraction
1999
A reliable and inexpensive goniometer head has been designed. Its stability, resulting from its compact construction, makes it very suitable for accurate measurements. Moreover, its space-saving design facilitates its application in X-ray data collection using charge-coupled device (CCD) detectors. This head has been improved for high-temperature measurements and has been tested by comparison of accurate K0.88Rb0.12TiOPO4data collected both at room temperature and at 973 K on the same crystal. The excellent structure results obtained at 973 K during the 360 h of measurements prove the stability of the goniometer head.
Momentum dependence of the decay η→π+π−π0
1998
Abstract The π 0 momentum dependence of the decay η → π + π − π 0 has been measured with the Crystal Barrel detector. The analysis is based on 3230 events. The results of this independent measurement are compared to new chiral perturbation theory calculations and previous measurements.
Timing techniques applied to distributed modular high-energy astronomy: the H.E.R.M.E.S. project
2021
The HERMES-TP/SP (High Energy Rapid Modular Ensemble of Satellites -- Technologic and Scientific Pathfinder) is an in-orbit demonstration of the so-called distributed astronomy concept. Conceived as a mini-constellation of six 3U nano-satellites hosting a new miniaturized detector, HERMES-TP/SP aims at the detection and accurate localisation of bright high-energy transients such as Gamma-Ray Bursts. The large energy band, the excellent temporal resolution and the wide field of view that characterize the detectors of the constellation represent the key features for the next generation high-energy all-sky monitor with good localisation capabilities that will play a pivotal role in the future …
Definition of a Model-Based Detector of Curvilinear Regions
2007
This paper describes a new approach for detection of curvilinear regions. These features detection can be useful for any matching based algorithm such as stereoscopic vision. Our detector is based on curvilinear structure model, defined observing the real world. Then, we propose a multi-scale search algorithm of curvilinear regions and we report some preliminary results.
Cyclotron radiation emission spectroscopy signal classification with machine learning in project 8
2019
The Cyclotron Radiation Emission Spectroscopy (CRES) technique pioneered by Project 8 measures electromagnetic radiation from individual electrons gyrating in a background magnetic field to construct a highly precise energy spectrum for beta decay studies and other applications. The detector, magnetic trap geometry, and electron dynamics give rise to a multitude of complex electron signal structures which carry information about distinguishing physical traits. With machine learning models, we develop a scheme based on these traits to analyze and classify CRES signals. Understanding and proper use of these traits will be instrumental to improve cyclotron frequency reconstruction and help Pro…
"Table 2" of "Transverse momentum spectra and nuclear modification factors of charged particles in pp, p-Pb and Pb-Pb collisions at the LHC"
2019
Transverse momentum spectra of charged particles in PbPb collisions in nine centrality classes.