Preliminary results on the electrostatic double-layer force between two surfaces with high surface potentials
1998
Abstract The aim of this study is to measure interaction forces between surfaces with high electric potentials in aqueous electrolyte solutions. Therefore the force between a gold sample and a gold sphere attached to the end of an atomic force microscope cantilever was measured. Gold sample and sphere were electrically connected and served as the working electrode. A potential was applied via a platinized platinum electrode. Experimental results are compared to forces approximated with the Poisson-Boltzmann theory.
Tevatron Run II combination of the effective leptonic electroweak mixing angle
2018
The Ministry of Science and Innovation and the Consolider-Ingenio 2010 Program and the European Union community Marie Curie Fellowship Contract No. 302103.
Drift Time Measurement in the ATLAS Liquid Argon Electromagnetic Calorimeter using Cosmic Muons
2010
The ionization signals in the liquid argon of the ATLAS electromagnetic calorimeter are studied in detail using cosmic muons. In particular, the drift time of the ionization electrons is measured and used to assess the intrinsic uniformity of the calorimeter gaps and estimate its impact on the constant term of the energy resolution. The drift times of electrons in the cells of the second layer of the calorimeter are uniform at the level of 1.3% in the barrel and 2.8% in the endcaps. This leads to an estimated contribution to the constant term of (0.29-0.04+0.05)% in the barrel and (0.54-0.04+0.06)% in the endcaps. The same data are used to measure the drift velocity of ionization electrons …
Determination of trace elements by resonant ionization mass spectrometry (RIMS)
1988
A resonant ionization mass spectrometer has been developed as an analytical tool for the detection of trace elements, especially of plutonium and other radionuclides. The sample, deposited on a rhenium filament, is evaporated by electrical heating and the atoms of the element under investigation are selectively ionized by laser light delivered from three dye lasers pumped by a copper vapour laser. The resulting photoions are detected in a time-of-flight spectrometer with a channelplate detector. For plutonium a mass resolution of M/δM=1500 was obtained and an overall detection efficiency of 4×10−6 was determined for stepwise excitation and ionization via autoionizing states. With a laser li…
High resolution 80Se(n,γ) cross section measurement at CERN n_TOF and development of the novel i-TED detection system
2022
El proceso (-s) de captura lenta de neutrones es responsable de la formación de la mitad de los elementos más pesados que el hierro en el universo. A pesar de la larga escala de tiempo de este proceso, la larga vida media de algunos isótopos inestables a lo largo del flujo de reacción del proceso-s crea puntos de ramificación que conducen a una división de la ruta de la nucleosíntesis. 79Se (t1/2 = 3.27 x 10^5 y) representa uno de los núcleos ramificados-s más relevantes y debatidos por dos razones principales. Por un lado, la existencia de estados excitados de baja energía en el 79Se, cuya población puede variar con la temperatura del medio estelar, hace que el patrón de abundancia local…
ECG-gated multislice computed tomography angiography as a comprehensive non-invasive imaging tool in patient with aortic coarctation
2021
We describe a case of a 52-year-old-woman with aortic coarctation demonstrated by means of 40-slice MSCT angiography. Based on the information extracted from MSCT it was possible to display the anatomical configuration of the disease, the thoraco-abdominal collateral pathways. The best therapeutic approach was established on the basis of MSCT findings. MSCT is a reliable and comprehensive tool for the assessment of adult patients with aortic coarctation. (www.actabiomedica.it).
Exploring the mass surface near the rare-earth abundance peak via precision mass measurements at JYFLTRAP
2019
The JYFLTRAP double Penning trap at the Ion Guide Isotope Separator On-Line (IGISOL) facility has been used to measure the atomic masses of 13 neutron-rich rare-earth isotopes. Eight of the nuclides, $^{161}$Pm, $^{163}$Sm, $^{164,165}$Eu, $^{167}$Gd, and $^{165,167,168}$Tb, were measured for the first time. The systematics of the mass surface has been studied via one- and two-neutron separation energies as well as neutron pairing-gap and shell-gap energies. The proton-neutron pairing strength has also been investigated. The impact of the new mass values on the astrophysical rapid neutron capture process has been studied. The calculated abundance distribution results in a better agreement w…
The thin and medium filters of the EPIC camera on-board XMM-Newton: measured performance after more than 15 years of operation
2016
After more than 15 years of operation of the EPIC camera on board the XMM-Newton X-ray observatory, we have reviewed the status of its Thin and Medium filters. We have selected a set of Thin and Medium back-up filters among those still available in the EPIC consortium and have started a program to investigate their status by different laboratory measurements including: UV/VIS transmission, Raman scattering, X-Ray Photoelectron Spectroscopy, and Atomic Force Microscopy. Furthermore, we have investigated the status of the EPIC flight filters by performing an analysis of the optical loading in the PN offset maps to gauge variations in the optical and UV transmission. We both investigated repea…
Système distribué d'alerte de la qualité de l'eau pour la rivière Mudan basé sur l'EFDC et les SIG
2016
Simulation and Early Warning System (SEWS) is a powerful tool for river water quality monitoring. Mudan River, an important river in northeastern cold regions of China, can run out of China into Russia. Thus, the water quality of Mudan River is highly concerned not only locally andregionally but also internationally. Objective of this study is to establish an excellent SEWS of water quality so that the spatio-temporal distribution of water quality in both open-water and ice-covered periods can be accurately simulated and visualized to understand the spatial variation of pollutants along the river course. The dissertation is structured into 7 chapters, chapter 1 outlines the background of th…
Measurement of the n-TOF beam profile with a micromegas detector
2004
A Micromegas detector was used in the neutron Time-Of-Flight (n_TOF) facility at CERN to evaluate the spatial distribution of the neutron beam as a function of its kinetic energy. This was achieved over a large range of neutron energies by using two complementary processes: at low energy by capture of a neutron via the 6Li(n,[alpha])t reaction, and at high energy by elastic scattering of neutrons on gas nuclei (argon+isobutane or helium+isobutane). Data are compared to Monte Carlo simulations and an analytic function fitting the beam profile has been calculated with a sufficient precision to use in neutron capture experiments at the n_TOF facility. http://www.sciencedirect.com/science/artic…