Search results for "detector"
showing 10 items of 3491 documents
Spectroscopic Tools Applied to Flerovium Decay Chains
2020
Abstract An upgraded TASISpec setup, with the addition of a veto DSSD and the new Compex detector-germanium array, has been employed with the gas-filled recoil separator TASCA at the GSI Helmholtzzentrum für Schwerionenforschung Darmstadt, to study flerovium (element 114) decay chains. The detector upgrades along with development of new analytical techniques have improved the sensitivity of the TASISpec setup for measuring α-photon coincidences. These improvements have been assessed with test reactions. The reaction 48Ca+206,207Pb was used for verification of experimental parameters such as transmission to implantation DSSD and target-segment to α-decay correlations. The reaction 48Ca+ nat …
Recent results on heavy-ion induced reactions of interest for neutrinoless double beta decay at INFN-LNS
2019
Abstract The NUMEN project aims at accessing experimentally driven information on Nuclear Matrix Elements (NME) involved in the half-life of the neutrinoless double beta decay (0νββ). In this view measurements of Heavy Ion (HI) induced Double Charge Exchange (DCE) reaction cross sections are performed with high-accuracy. In particular, the (18O,18Ne) and (20Ne,20O) reactions are used as tools for β+β+ and β-β- decays, respectively. In the experiments, performed at INFN - Laboratory Nazionali del Sud (LNS) in Catania, the beams are accelerated by the Superconducting Cyclotron (CS) and the reaction ejectiles are detected the MAGNEX magnetic spectrometer. The measured cross sections are challe…
Overview and accomplishments of the Borexino experiment
2015
International audience; The Borexino experiment is running at the Laboratori del Gran Sasso in Italy since 2007. Its technical distinctive feature is the unprecedented ultralow background of the inner scintillating core, which is the basis of the outstanding achievements accumulated by the experiment. In this talk, after recalling the main features of the detector, the impressive solar data gathered so far by the experiment will be summarized, with special emphasis to the most recent and prominent result concerning the detection of the fundamental pp solar neutrino flux, which is the direct probe of the engine mechanism powering our star. Such a milestone measurement puts Borexino in the un…
Class-B two-photon Fabry–Pérot laser
1998
Abstract We study the stationary operation and stability properties of a class-B two-photon Fabry–Perot laser. We show that, differently from the one-photon laser, the intensity emitted by the two-photon laser is larger in a Fabry–Perot than in a ring cavity. The lasing solution loses stability through a subcritical Hopf bifurcation, as it occurs in the unidirectional ring laser. The stability domain in the parameter space is larger in the Fabry–Perot than in the ring cavity configuration.
One- and two-photon lasers with injected signal in a high-Q fabry-Pérot cavity
2000
Explicit models are derived for good cavity one- and two-photon lasers with an injected signal in a Fabry-Perot cavity. The steady solutions and their stability properties are obtained analytically and compared with the corresponding ring cavity model ones. Only quantitative differences between both types of cavities are found. In particular we show that (i) the Fabry-Perot cavity reduces significantly the domain of self-pulsing with respect to the ring cavity, and for the two-photon laser case (ii) larger output can be extracted from a Fabry-Perot cavity than from a ring cavity under certain conditions, something impossible in free-running lasers. We conclude that ring cavity models are se…
The Wide Field Imager instrument for Athena
2017
ESA's next large X-ray mission ATHENA is designed to address the Cosmic Vision science theme 'The Hot and Energetic Universe'. It will provide answers to the two key astrophysical questions how does ordinary matter assemble into the large-scale structures we see today and how do black holes grow and shape the Universe. The ATHENA spacecraft will be equipped with two focal plane cameras, a Wide Field Imager (WFI) and an X-ray Integral Field Unit (X-IFU). The WFI instrument is optimized for state-of-The-Art resolution spectroscopy over a large field of view of 40 amin x 40 amin and high count rates up to and beyond 1 Crab source intensity. The cryogenic X-IFU camera is designed for high-spect…
Plasma distributions observed in a 2.45 GHz hydrogen discharge
2014
The existence of various spatial distributions of hydrogen plasma in a pulsed 2.45 GHz microwave discharge is demonstrated. The data has been obtained through optical emission diagnostics utilizing an ultra-fast CCD camera system with multi-channel plate (MCP) intensifiers, and a wavelength-filtered photodiode recording temporal light emission signals of hydrogen atoms and molecules. It has been observed that the magnetic field topology and strength are determining the transitions between different plasma patterns and spectral saturation times while neutral gas pressure and microwave power show a weaker influence on the profiles but affect the emitted light intensity.
Beta-decay of light nuclei close to the proton drip-line: 40Ti and 35Ca
1998
The s-decay of40Ti and35Ca have been studied at the LISE3 spectrometer at GANIL. The decay schemes were deduced from the observed s-delayed proton and γ emission of40Ti and35Ca into the ground and first excited states of39Ca and34Ar, respectively. The Gamow-Teller strength functionB(GT) of the40Ti s-decay extracted from the s-decay branching ratios and the precisely measured40Ti half-life, provides for the first time an experimental calibration of the neutrino detection efficiency for the ICARUS solar neutrino detector.
Development of the Pixel Detector for the Belle II experiment and top quark mass measurement in radiative events at the future electron-positron line…
2019
Durante los últimos cien años, los numerosos descubrimientos en los colisionadores de partículas y desarrollos teóricos han conducido a los físicos de partículas a construir el Modelo Estándar, el modelo teórico más exitoso hasta la fecha. Sin embargo, a pesar de su gran éxito, el Modelo Estándar no describe toda la fenomenología observada actualmente en los diferentes experimentos. Es por ello que se necesitan nuevos colisionadores que proporcionen observaciones de nueva física que nos ayuden a construir modelos que describan dicha fenomenología. Para enfrentarse al reto, la comunidad de física de partículas se une formando grandes colaboraciones, con el propósito de diseñar y construir lo…
Rapidity correlations in Lambda baryon and proton production in hadronic Z0 decays
1998
In an analysis of multihadronic events recorded at LEP by DELPHI in the years 1992 through 1994, charged hadrons are identified using the measurement of their energy loss and their Cherenkov angle. Rapidity correlations of \La-\La, proton-proton, and \La-proton pairs are compared. The agreement with the string and cluster fragmentation models is tested. For those pairs that frame a meson in terms of rapidity the compensation of strangeness is studied. For \La{}$\overline{\mathrm{p}}$ pairs the additional correlation with respect to charged kaons is analysed.