Search results for "detector"
showing 10 items of 3491 documents
Precise measurement of $2\nu\beta\beta$ decay of $^{100}$Mo with the CUPID-Mo detection technology
2020
We report the measurement of the two-neutrino double-beta ($2\nu\beta\beta$) decay of $^{100}$Mo to the ground state of $^{100}$Ru using lithium molybdate (\crystal) scintillating bolometers. The detectors were developed for the CUPID-Mo program and operated at the EDELWEISS-III low background facility in the Modane underground laboratory. From a total exposure of $42.235$ kg$\times$d, the half-life of $^{100}$Mo is determined to be $T_{1/2}^{2\nu}=[7.12^{+0.18}_{-0.14}\,\mathrm{(stat.)}\pm0.10\,\mathrm{(syst.)}]\times10^{18}$ years. This is the most accurate determination of the $2\nu\beta\beta$ half-life of $^{100}$Mo to date. We also confirm, with the statistical significance of $>3\sigm…
Gamma activity and geochemical features of building materials: estimation of gamma dose rate and indoor radon levels in Sicily.
2001
A high-purity germanium detector has been used to measure the abundance of radium (Ra), thorium (Th) and potassium (K) in building materials used in Sicilian dwellings. The measurements were performed to evaluate which material was suitable for the construction of an enclosure, which would have a low background emission. The materials examined in this work showed concentrations of 226Ra, 232Th and 40K dramatically variable depending on the lithologies, particularly in the case of blocks, sands and aggregates commonly used in building materials in Sicily. The results are discussed and a criterion is indicated to reduce the radiation dose to humans. Since radon inlet is a major health problem…
Logic Functions with Stimuli-Responsive Single Nanopores
2014
[EN] We present the concept of logic functions based on a single stimuli-responsive nanopore and analyze its potential for electrochemical transducers and actuators. The responsive molecules at the surface of the polymeric nanopore immersed in an electrolyte solution are sensitive to thermal, chemical, electrical, and optical stimuli, which are the input signals required to externally tune the conductance of the nanopore (the logical output). A single nanostructure can be operated as a resistor or as a diode with a broad range of rectifying properties, allowing for logical information-processing schemes that are useful pH and temperature sensors, electro-optical detectors, and electrochemic…
Génération et détection d'électrons chauds dans des dispositifs plasmoniques
2021
Hot carrier-based devices are quite promissing for ultrafast photodetection and toset off enhanced physicochemical reactions. Controlling their generation at the nanoscale within plasmonic devices is a key for the future development of hybrid hot carriers technologies. Indeed, Surface PlasmonPolaritons (SPPs) can be exploited to confine light and enhance the number of excited hot carriers. We aim at studying the excitation and dynamics of hot carriers, enhanced by plasmonics, with two different approaches.In a first approach, we aim at controlling the delocalized generation of hot carriers by a propagative SPP. A plasmonic waveguide with a grating coupler is employed. Hot electrons are indi…
Superconducting Solenoid System with Adjustable Shielding Factor for Precision Measurements of the Properties of the Antiproton
2019
Physical review applied 12(4), 044012 (2019). doi:10.1103/PhysRevApplied.12.044012
Simulation of PLL with impulse signals in MATLAB: Limitations, hidden oscillations, and pull-in range
2015
The limitations of PLL simulation are demonstrated on an example of phase-locked loop with triangular phase detector characteristic. It is shown that simulation in MatLab may not reveal periodic oscillations (e.g. such as hidden oscillations) and thus may lead to unreliable conclusions on the width of pull-in range.
Characterization of a medium size Xe/TMA TPC instrumented with microbulk Micromegas, using low-energy gamma-rays
2014
NEXT-MM is a general-purpose high pressure (10 bar, $\sim25$ l active volume) Xenon-based TPC, read out in charge mode with an 8 cm $\times$8 cm-segmented 700 cm$^2$ plane (1152 ch) of the latest microbulk-Micromegas technology. It has been recently commissioned at University of Zaragoza as part of the R&D of the NEXT $0\nu\beta\beta$ experiment, although the experiment's first stage is currently being built based on a SiPM/PMT-readout concept relying on electroluminescence. Around 2 million events were collected during the last months, stemming from the low energy $\gamma$-rays emitted by a $^{241}$Am source when interacting with the Xenon gas ($\epsilon$ = 26, 30, 59.5 keV). The localized…
Present Status and Future Perspectives of the NEXT Experiment
2014
Gómez Cadenas, Juan José et al.
NEXT-100 Technical Design Report (TDR). Executive summary
2012
[EN] In this Technical Design Report (TDR) we describe the NEXT-100 detector that will search for neutrinoless double beta decay (ßß0v) in 136XE at the Laboratorio Subterráneo de Canfranc (LSC), in Spain. The document formalizes the design presented in our Conceptual Design Report (CDR): an electroluminescence time projection chamber, with separate readout planes for calorimetry and tracking, located, respectively, behind cathode and anode. The detector is designed to hold a maximum of about 150 kg of xenon at 15 bar, or 100 kg at 10 bar. This option builds in the capability to increase the total isotope mass by 50% while keeping the operating pressure at a manageable level. The readout pla…
Initial results of NEXT-DEMO, a large-scale prototype of the NEXT-100 experiment
2013
NEXT-DEMO is a large-scale prototype of the NEXT-100 detector, an electroluminescent time projection chamber that will search for the neutrinoless double beta decay of Xe-136 using 100-150 kg of enriched xenon gas. NEXT-DEMO was built to prove the expected performance of NEXT-100, namely, energy resolution better than 1% FWHM at 2.5MeV and event topological reconstruction. In this paper we describe the prototype and its initial results. A resolution of 1.75% FWHM at 511 keV (which extrapolates to 0.8% FWHM at 2.5 MeV) was obtained at 10 bar pressure using a gamma-ray calibration source. Also, a basic study of the event topology along the longitudinal coordinate is presented, proving that it…