Search results for "detector"
showing 10 items of 3491 documents
MDCT and virtual angioscopy in spontaneous aortocaval fistula
2007
Aortocaval fistula is a rare, less than 1%, but life threatening complication, of abdominal aortic aneurysm. Mortality is high but prompt recognition of the fistula can reduce mortality rate. The multidetector row CT (MDCT) findings in a 69-year-old patient with a complex medical history characterized by previous episodes of myocardial ischemia, is reported. MDCT shows an early homogeneous enhancement of the inferior vena cava, slightly dilated at the liver level and markedly narrowed above the renal vein due to aneurysm compression. The patient underwent to emergency laparotomy but died during surgery for cardiac arrest. MDCT allows a prompt recognition of the fistula and different compute…
Standard and non-standard neutrino properties
2002
I review the interpretation of solar and atmospheric neutrino data in terms neutrino oscillations and describe some ways to account for the required neutrino masses and mixing angles from first principles, both within top-down and bottom-up approaches. I also discuss non-oscillation phenomena such as nu-less double beta which may probe the absolute scale of neutrino mass, and also reveal its Majorana nature. I note that leptonic CP violation induced by ``Majorana'' phases drop from oscillations but play a role in the leptogenesis scenario for the baryon asymmetry of the Universe. Direct tests of leptonic CP violation in oscillation experiments, such as neutrino factories, will be a tough ch…
Helium and Argon Line Broadening in the nu2 Band of CH4
2004
Abstract The spectra of the gaseous mixtures CH 4 –He and CH 4 –Ar were obtained in the spectral region 1400–1750 cm −1 with a resolution up to 0.003 cm −1 . Helium and argon pressure broadenings for the vibration–rotation lines of the ν 2 band of CH 4 have been estimated at room temperature for some lines in the P , Q , and R branches. These values were also calculated using the theoretical approach developed by Robert and Bonamy, extended to the case of tetrahedral molecules. The helium data have been found to be in a satisfactory agreement whereas a divergence of calculated and measured broadening coefficients has been evidenced in the case of argon. Simulations of the ν 2 band shapes of…
Energy resolution and throughput of a new real time digital pulse processing system for x-ray and gamma ray semiconductor detectors
2013
New generation spectroscopy systems have advanced towards digital pulse processing (DPP) approaches. DPP systems, based on direct digitizing and processing of detector signals, have recently been favoured over analog pulse processing electronics, ensuring higher flexibility, stability, lower dead time, higher throughput and better spectroscopic performance. In this work, we present the performance of a new real time DPP system for X-ray and gamma ray semiconductor detectors. The system is based on a commercial digitizer equipped with a custom DPP firmware, developed by our group, for on-line pulse shape and height analysis. X-ray and gamma ray spectra measurements with cadmium telluride (Cd…
High Voltage Insulation and Gas Absorption of Polymers in High Pressure Argon and Xenon Gases
2018
High pressure gas time projection chambers (HPGTPCs) are made with a variety of materials, many of which have not been well characterized in high pressure noble gas environments. As HPGTPCs are scaled up in size toward ton-scale detectors, assemblies become larger and more complex, creating a need for detailed understanding of how structural supports and high voltage insulators behave. This includes the identification of materials with predictable mechanical properties and without surface charge accumulation that may lead to field deformation or sparking. This paper explores the mechanical and electrical effects of high pressure gas environments on insulating polymers PTFE, HDPE, PEEK, POM …
Experimental evidence of high spatial confinement of elastic energy in a phononic cantilever
2021
We report on experimental high spatial confinement of elastic energy in a silicon phononic cantilever for which the quality factor of a higher-order flexural resonance is increased by a factor of 27 (from Q ∼ 80 to Q ∼ 2130) with the use of a three-row phononic crystal (PnC) strip. As shown by numerical simulations performed with the finite element method, the PnC both reduces anchor loss and confines elastic energy inside the cantilever. The PnC and the cantilever are fabricated with standard clean room techniques on a silicon on insulator substrate. Optical measurements of the out-of-plane displacements are performed with a laser scanning interferometer in a frequency range around 2 MHz.
Design and realization of a portable multichannel continuous wave fNIRS
2014
A design and implementation of a portable functional Near InfraRed Spectroscopy embedded system prototype is described. In this theoretical and experimental work, we present an embedded system hosting 64 LED sources and 128 Silicon PhotoMultiplier detectors (SiPM). The elementary part of the structure is a flexible probe “leaf” consisting of 16 SiPMs, 4 couples of LEDs, each operating at two wavelengths, and a temperature sensor. The hardware system is based on an ARM main microcontroller that allows to perform both the switching time of LEDs and the acquisition of the SiPM outputs. The performed preliminary experimental tests achieved very promising results, thus demonstrating the effectiv…
Strong chiral dichroism and enantiopurification in above-threshold ionization with locally chiral light
2021
We derive here a highly selective photoelectron-based chirality-sensing technique that utilizes “locally chiral” laser pulses. We show that this approach results in strong chiral discrimination, where the standard forwards/backwards asymmetry of photoelectron circular dichroism (PECD) is lifted. The resulting dichroism is larger and more robust than conventional PECD (especially in the high-energy part of the spectrum), is found in all hemispheres, and is not symmetric or antisymmetric with respect to any symmetry operator. Remarkably, chiral dichroism of up to 10% survives in the angularly integrated above-threshold ionization (ATI) spectra, and chiral dichroism of up to 5% survives in the…
High-power pulsed dye laser with Fourier-limited bandwidth
1986
A high-peak-power, narrow-linewidth light source with a homogeneous beam profile has been constructed by modifications to a commercially available pulsed-dye-laser system. Output pulses of up to 10 mJ were generated with linewidths of about 50 MHz for 12-nsec pulses. The pulse-to-pulse frequency stability was better than the linewidth, and the center frequency could be scanned over a frequency range of 142.5 GHz at a wavelength of 600 nm. The performance of the system was demonstrated by observing the 6s2 1S0–6s7s1S0 transition in atomic mercury at 2λ = 312.8 nm and the 6s2S1/2–8s2S1/2 transition in atomic gold at 2λ = 308.9 nm using up to 1 mJ of frequency-doubled output for two-photon non…
Charge Transport in Trap-Sensitized Infrared PbS Quantum-Dot-Based Photoconductors: Pros and Cons
2018
Control of quantum-dot (QD) surface chemistry offers a direct approach for the tuning of charge-carrier dynamics in photoconductors based on strongly coupled QD solids. We investigate the effects of altering the surface chemistry of PbS QDs in such QD solids via ligand exchange using 3-mercaptopropionic acid (MPA) and tetrabutylammonium iodide (TBAI). The roll-to-roll compatible doctor-blade technique was used for the fabrication of the QD solid films as the photoactive component in photoconductors and field-effect phototransistors. The ligand exchange of the QD solid film with MPA yields superior device performance with higher photosensitivity and detectivity, which is due to less dark cur…