Search results for "device"

showing 10 items of 1286 documents

Clinical analysis following lumbar interspinous devices implant: where we are and where we go

2014

Objectives:We present our experience with patients treated with interspinous devices who are affected by neurogenic intermittent claudication (NIC) or lumbar disc herniation (LDH) where the interspinous system has been inserted following microdiscectomy.Study design:Retrospective study.Methods:This study included patients (n=100) with NIC secondary to lumbar spinal stenosis (group 1), and patients (n=100) with LDH (group 2) in whom the interspinous device has been implanted following radicular decompression in a period spanning 6 years. The latter have been compared with a homogenous group of patients (n=100) where no interspinous system has been implanted following microdiscectomy (group 3…

AdultMaleReoperationMicrosurgerymedicine.medical_specialtyTime FactorsVisual analogue scaleDecompressionlumbar interspinous devicesAdult Prostheses and Implants Aged Decompression Surgical Disability Evaluation Female Follow-Up Studies Intermittent Claudication Intervertebral Disc Displacement Humans Lumbar Vertebrae Microsurgery Minimally Invasive Surgical Procedures Middle Aged Male Retrospective Studies Pain Measurement Patient Satisfaction Surveys and Questionnaires Reoperation Recurrence Treatment Outcome Spinal StenosisDisability EvaluationSpinal StenosisLumbarRecurrenceSurveys and QuestionnairesmedicineHumansMinimally Invasive Surgical ProceduresAgedPain MeasurementRetrospective StudiesLumbar VertebraeSettore MED/27 - Neurochirurgiabusiness.industryLumbar spinal stenosisProstheses and ImplantsGeneral MedicineIntermittent ClaudicationMiddle AgedDecompression Surgicalmedicine.diseaseIntermittent claudicationOswestry Disability IndexSurgeryTreatment OutcomeNeurologyPatient SatisfactionFemaleNeurology (clinical)Implantmedicine.symptombusinessClaudicationIntervertebral Disc DisplacementFollow-Up StudiesSpinal Cord
researchProduct

Complex radial head and neck fractures treated with modern locking plate fixation

2019

Background Internal fixation of complex radial head and neck (CRHN) fractures is difficult, and postoperative complications are common. This study evaluated elbow function and patient clinical status after internal fixation of CRHN fractures with modern locking plates. Methods We included 40 patients with 41 fractures (1 bilateral lesion). In 25 patients (61%), a concomitant injury was found. Patients were an average age of 46 years (range, 22-70 years). The mean follow-up time was 36 months (range, 2-70 months). Postoperative assessments included evaluation of range of motion, functional scores, and radiologic findings. We assessed fracture healing, surgical complications, revision surgery…

AdultMaleReoperationmedicine.medical_specialtyJoint replacementmedicine.medical_treatmentElbowBone healingSupinationFracture Fixation InternalYoung Adult03 medical and health sciencesFixation (surgical)0302 clinical medicineElbow JointHumansMedicineInternal fixationPronationOrthopedics and Sports MedicineRange of Motion ArticularDevice RemovalAgedFracture Healing030222 orthopedicsbusiness.industry030229 sport sciencesGeneral MedicineMiddle AgedSurgeryTreatment Outcomemedicine.anatomical_structureConcomitantFemaleSurgeryRadial head fractureRadius FracturesbusinessRange of motionBone PlatesEpiphysesFollow-Up StudiesJournal of Shoulder and Elbow Surgery
researchProduct

Orthopedic and neurosurgical treatment of severe kyphosis in myelomeningocele

1999

Kyphosis in myelomeningocele is characterized by a complex pattern of problems during development and therapy. On the one hand, decompensation of upright posture leads to loss of sitting ability and social integration; on the other hand, accompanying malformations and trophic alterations threaten the physical integrity and performance. Neurologic function, cerebrospinal fluid (CSF) circulation, skeletal deformity and the urinary transport system need to be kept in mind and need to be treated with cooperation between the different specialties. Especially during serious surgical interventions such as spinal surgery, neither the nervous system nor the kidneys must be ignored. Sixteen patients …

AdultMaleReoperationmedicine.medical_specialtyMeningomyeloceleAdolescentUrinary systemNeurosurgeryKyphosisCentral nervous system diseasemedicineHumansDecompensationKyphosisChildbiologybusiness.industrySoft tissueGeneral MedicineGibbusbiology.organism_classificationmedicine.diseaseMagnetic Resonance ImagingOrthopedic Fixation DevicesSurgeryRadiographyOrthopedicsTreatment OutcomeChild PreschoolOrthopedic surgeryFemaleSurgeryNeurology (clinical)NeurosurgerybusinessNeurosurgical Review
researchProduct

Physiological responses and parasympathetic reactivation in rescue interventions: The effect of the breathing apparatus.

2018

This study aimed to assess the effect of wearing a breathing apparatus during a simulated rescue intervention on psychophysiological responses and parasympathetic reactivation of firefighters. Thirty-four firefighters participated in this study which consisted of four experimental sessions conducted randomly: a maximal fitness test and three rescue interventions performed (a) with personal protective clothing (PPC); (b) with PPC and the full self-contained breathing apparatus (SCBA), including cylinder, full-face piece, and breathing regulator; and (c) with PPC and only the cylinder of the self-contained breathing apparatus (SCBAc). Physiological (heart rate [HR], breathing frequency [BF]) …

AdultMaleRespiratory rate[SDV]Life Sciences [q-bio]Physical Therapy Sports Therapy and Rehabilitation030204 cardiovascular system & hematology03 medical and health sciences0302 clinical medicineProtective ClothingHeart RateParasympathetic Nervous SystemStress PhysiologicalHeart rateHeart rate variabilityMedicineHumansOrthopedics and Sports MedicineRespiratory Protective DevicesSimulation TrainingComputingMilieux_MISCELLANEOUSRating of perceived exertionCross-Over Studiesbusiness.industry030229 sport sciencesPhysiological responsesAutonomic nervous systemFitness testPhysical FitnessAnesthesiaFirefightersBreathingFemalebusinessStress PsychologicalScandinavian journal of medicinescience in sports
researchProduct

A dangerous design for a mountain bike.

2001

The case of a man’s death as a consequence of an accident with a mountain bike was examined. Despite only slight external injuries, a general examination revealed the existence of a rupture of the diaphragm which was the ultimate cause of death. The discussion reconstructs the way the accident occurred and briefly analyses the consequences of safety design in two-wheeled vehicles.

AdultMaleRuptureEngineeringbusiness.industrySafety designDiaphragmDiaphragm (mechanical device)Equipment DesignPathology and Forensic MedicineBicyclingCause of DeathForensic engineeringHumansbusinesshuman activitiesCause of deathInternational journal of legal medicine
researchProduct

Atraumatic maxillary sinus elevation using threaded bone dilators for immediate implants. A three-year clinical study.

2008

Objective: The aim of this study was to evaluate the efficacy of sinus floor elevation using sequential bone dilators. Materials and Methods: Thirty patients took part in the study (18 women and 12 men) with ages ranging between thirty-six and sixty-three years, selected according to inclusion and exclusion criteria, who showed a bone deficit in the upper posterior alveolar margin of 5-8 mm in height. Sixty expanded platform internal connection implants were placed with diameters of 4/5/4 mm and lengths varying between 10 (n=10) and 11.5 mm (n= 50). Results: Data obtained were analyzed using SPSS 15.0 software. The average intra-sinus bone gain with MP3 biomaterial of porcine origin was 4.1…

AdultMaleTime FactorsMaxillary sinusmedicine.medical_treatmentDentistryProsthesisClinical studyAlveolar ridgeMedicineHumansProspective StudiesProspective cohort studyGeneral DentistryDental Implantsbusiness.industryTissue Expansion DevicesMaxillary SinusMiddle Aged:CIENCIAS MÉDICAS [UNESCO]medicine.anatomical_structureOtorhinolaryngologyMaxillaInclusion and exclusion criteriaUNESCO::CIENCIAS MÉDICASSurgeryFemaleImplantbusinessMedicina oral, patologia oral y cirugia bucal
researchProduct

Repetition and form priming interact with neighborhood density at a brief stimulus onset asynchrony.

2001

The relationships between repetition- and form-priming effects and neighborhood density were analyzed in two masked priming experiments with the lexical decision task. Given that form-priming effects appear to be influenced by a word's orthographic neighborhood, it is theoretically important to find out whether repetition priming also differs as a function of the word's orthographic neighborhood. Within an activation framework, repetition- and form-priming effects are just quantitatively different phenomena, whereas the two effects are qualitatively different in a serial-ordered model of lexical access (the entry-opening model). The results show that repetition- and form-priming effects wer…

AdultMaleTime FactorsRepetition primingExperimental and Cognitive PsychologyModels PsychologicalAffect (psychology)Arts and Humanities (miscellaneous)Developmental and Educational PsychologyLexical decision taskHumansResponse primingCommunicationRepetition (rhetorical device)business.industryStimulus onset asynchronyLinguisticsRecognition PsychologyInhibition PsychologicalPattern Recognition VisualFemaleCuesPsychologybusinessPriming (psychology)Word (group theory)Cognitive psychologyPsychonomic bulletinreview
researchProduct

Plaque removal efficacy of power and manual toothbrushes: a comparative study

2009

The aim of this study was to compare the plaque removal efficacy of a new oscillating/rotating/pulsating toothbrush [Oral-B® Professional Care® 8500 (PC 8500)] with two manual toothbrushes [Oral-B® CrossAction™ Vitalizer (CAV) and Oral-B® Indicator™ (IND), respectively]. The safety of the PC 8500 was also assessed. The study was a single-use, observer-masked, randomised 3×3 Latin square crossover design balanced for carryover effects. The enrolled subjects (n=66) refrained from brushing for 23–25 h before each clinical examination. Plaque scores were recorded before and after brushing with the allocated toothbrush using the Turesky et al. modification of the Quigley and Hein plaque index. T…

AdultMaleToothbrushingPlaque indexAdolescentPlaque removalPlaque removalDental PlaqueDentistryManual toothbrushPlaque controlStatistics Nonparametriclaw.inventionDental Devices Home CareRandomised crossover single-use studyPower toothbrushYoung AdultElectricitylawSettore MED/28 - Malattie OdontostomatologicheMedicineHumansSingle-Blind MethodManual toothbrushGeneral DentistryAnalysis of VarianceChi-Square DistributionCross-Over StudiesEquipment Safetybusiness.industryDental Plaque IndexMiddle AgedCrossover studyDental Plaque IndexSafety EquipmentPlaque indexFemaleToothbrushSafetybusiness
researchProduct

Jump Height from Inertial Recordings : A Tutorial for a Sports Scientist

2019

Jump performance provides meaningful information both for sporting and clinical needs. Current state-of-the-art in jump performance assessment is laboratory-bound, however, out-of-the-laboratory methods are desirable. Therefore, the purposes of the present investigation were 1) to explore whether utilising a novel analytical approach minimises the bias between inertial recording unit (IMU)-based and jump mat-based jump height estimates, and 2) to provide a thorough tutorial for a sport scientist (see appendix) to facilitate standardisation of jump height estimation. Forty one women, men and boys aged 6 to 77 years-of-age completed three maximal counter movement jumps without arm swing, whic…

AdultMalegyroscopeInertial frame of referenceCorrelation coefficientAdolescentMovementPhysical Therapy Sports Therapy and Rehabilitation030204 cardiovascular system & hematologyAccelerometerwearablelaw.invention03 medical and health sciencesWearable Electronic DevicesYoung Adult0302 clinical medicineInertial measurement unitlawAccelerometryHumansOrthopedics and Sports MedicineliikeanalyysiChildsignal processingSimulationMathematicsAgedinertial measurement unitLimits of agreementGyroscope030229 sport sciencesMiddle AgedBiomechanical PhenomenamittausmenetelmätaccelerometerArm swingJumpExercise TestFemalehyppääminenperformance
researchProduct

Diseño de una nueva prueba para medir la función de sensibilidad al contraste con iPad

2015

[EN] Purpose: To introduce a new application (ClinicCSF) to measure Contrast Sensitivity Function (CSF) with tablet devices, and to compare it against the Functional Acuity Contrast Test (FACT). Methods: A total of 42 subjects were arranged in two groups of 21 individuals. Different versions of the ClinicCSF (.v1 and .v2) were used to measure the CSF of each group with the same iPad and the results were compared with those measured with the FACT. The agreements between ClinicCSF and FACT for spatial frequencies of 3, 6, 12 and 18 cycles per degree (cpd) were represented by Bland---Altman plots. Results: Statistically significant differences in CSF of both groups were found due to the change…

AdultMalemedia_common.quotation_subjectVision DisordersVisual performanceFACTDesempeño visualCycles per degreeContrast SensitivityYoung Adultlcsh:OphthalmologyStatisticsHumansContrast (vision)lcsh:QC350-467Tablet devicesDiagnosis Computer-AssistedSensitivity (control systems)Simulationmedia_commonContrast sensitivity functionDispositivos de tabletaVision TestsMiddle AgedFunctional acuity contrast testConfidence intervalTest (assessment)Función de sensibilidad al contrasteiPadlcsh:RE1-994Computers HandheldFISICA APLICADAOriginal ArticleFemaleSpatial frequencyPsychologyEFAClcsh:Optics. LightOptometry
researchProduct