Search results for "device"

showing 10 items of 1286 documents

Time-energy filtering of single electrons in ballistic waveguides

2019

Characterizing distinct electron wave packets is a basic task for solid-state electron quantum optics with applications in quantum metrology and sensing. A important circuit element for this task is a non-stationary potential barrier than enables backscattering of chiral particles depending on their energy and time of arrival. Here we solve the quantum mechanical problem of single-particle scattering by a ballistic constriction in an fully depleted quantum Hall system under spatially uniform but time-dependent electrostatic potential modulation. The result describes electrons distributed in time-energy space according to a modified Wigner quasiprobability distribution and scattered with an …

PhysicsQuantum opticsCondensed Matter - Mesoscale and Nanoscale PhysicsWigner quasiprobability distributionWave packet500 Naturwissenschaften und Mathematik::530 Physik::530 PhysikGeneral Physics and AstronomyFOS: Physical sciencesElectronQuantum tomographyQuantum Hall effect01 natural sciences530010305 fluids & plasmasComputational physicsquantum state tomography0103 physical sciencesMesoscale and Nanoscale Physics (cond-mat.mes-hall)time-dependent scatteringQuantum metrologyWigner distribution functionelectron quantum optics010306 general physicssingle-electron devices
researchProduct

Stroboscopic Space Tag for Optical Time-Resolved Measurements with a Charge Coupled Device Detector

2018

Time-resolved measurements are extensively employed in the study of light–matter interaction at the nanoscale such as the exciton dynamics in semiconductors or the ultrafast intraband transitions in metals. Importantly, single-photon correlation, quantum state tomography, and other techniques devoted to the characterization of quantum optics systems rely on time-resolved experiments, whose resolution which is bound to the time response of the detector and related electronics. For this reason, multiplexing or beam deflection techniques have been recently proposed to overcome the detector resolution and thus measure the final photon distribution characteristics. Taking advantage of both strat…

PhysicsQuantum opticsbusiness.industryDetectorMeasure (physics)02 engineering and technologyQuantum tomography021001 nanoscience & nanotechnology01 natural sciencesSignalMultiplexingAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materials010309 opticsOptics0103 physical sciencesCharge-coupled deviceElectrical and Electronic Engineering0210 nano-technologybusinessUltrashort pulseBiotechnologyACS Photonics
researchProduct

Unidirectional reflection from an integrated "taiji" microresonator

2020

We study light transmission and reflection from an integrated microresonator device, formed by a circular microresonator coupled to a bus waveguide, with an embedded S-shaped additional crossover waveguide element that selectively couples counter-propagating modes in a propagation-direction-dependent way. The overall shape of the device resembles a "taiji"symbol, hence its name. While Lorentz reciprocity is preserved in transmission, the peculiar geometry allows us to exploit the non-Hermitian nature of the system to obtain high-contrast unidirectional reflection with negligible reflection for light incident in one direction and a significant reflection in the opposite direction.

PhysicsReciprocity; photonic device; microcavityLight transmissionbusiness.industryLorentz transformationCrossoverPhysics::Optics02 engineering and technologyÒptica021001 nanoscience & nanotechnology01 natural sciencesAtomic and Molecular Physics and OpticsElectronic Optical and Magnetic Materials010309 opticssymbols.namesakeOpticsReciprocity (electromagnetism)0103 physical sciencessymbols0210 nano-technologybusiness
researchProduct

SU-E-T-218: Octavius 4D: Commissioning and Clinical Implementation of a New Device for VMAT Verifications

2013

Purpose: To commission a new device for pre‐treatment patient specific verification of VMAT plans, which is capable of reconstructing 3D dose with high resolution. Methods: Octavius 4D system (PTW) consists of an ion chamber array embedded in a cylindrical phantom which, assisted by an inclinometer, rotates synchronously with the gantry. For VMAT plans, it measures planar dose distributions as a function of gantry angle in order to compute the resulting 3D dose distribution. There are two options for the ion chamber array: Octavius 729 (general purpose) and Octavius 1000 SRS (small field size, high resolution). We have used three linacs: two Varian Clinac iX and one TrueBeam with MLC HD 120…

PhysicsReproducibilitybusiness.industrymedicine.medical_treatmentTruebeamGeneral MedicineGantry angleRadiosurgeryLinear particle acceleratorSmall fieldIonization chambermedicineNew deviceNuclear medicinebusinessMedical Physics
researchProduct

Dynamic measurement of the elastic constant of an helicoidal spring by a smartphone

2021

Abstract We describe an educational activity that can be done by using smartphones to collect data in physics experiments aimed to measure the oscillating period of a spring-mass system and the elastic constant of the helicoidal spring by the dynamic method. Results for the oscillating period and for the elastic constant of the spring agree very well with measurements obtained by different methods. We also discuss the error analysis that can be done in an introductory physics laboratory at undergraduate level.

PhysicsScience instructionlaboratory experimentsharmonic oscillationsSpring (device)accelerometer sensorSettore FIS/08 - Didattica E Storia Della FisicaAcousticsGeneral Physics and AstronomyMotion (geometry)smartphoneConstant (mathematics)EducationPhysics Education
researchProduct

Readout of the UFFO Slewing Mirror Telescope to detect UV/optical photons from Gamma-Ray Bursts

2013

The Slewing Mirror Telescope (SMT) was proposed for rapid response to prompt UV/optical photons from Gamma-Ray Bursts (GRBs). The SMT is a key component of the Ultra-Fast Flash Observatory (UFFO)-pathfinder, which will be launched aboard the Lomonosov spacecraft at the end of 2013. The SMT utilizes a motorized mirror that slews rapidly forward to its target within a second after triggering by an X-ray coded mask camera, which makes unnecessary a reorientation of the entire spacecraft. Subsequent measurement of the UV/optical is accomplished by a 10 cm aperture Ritchey-Chretien telescope and the focal plane detector of Intensified Charge-Coupled Device (ICCD). The ICCD is sensitive to UV/opt…

PhysicsSpacecraftbusiness.industryApertureAstrophysics::High Energy Astrophysical PhenomenaAstrophysics::Instrumentation and Methods for AstrophysicsHigh voltagelaw.inventionTelescopeFlash (photography)OpticsData acquisitionlawCharge-coupled devicebusinessInstrumentationMathematical PhysicsSpace environment
researchProduct

Monte Carlo Analysis of Voltage-Current Characteristic Nonlinearity and Harmonic Generation in Submicron Semiconductor Structures

2006

Using a multiparticles Monte Carlo technique, we investigate the dependence of the nonlinear carrier dynamics in GaAs n+nn+ structures operating under very intense sub-terahertz signals from some process parameters as: i) the frequency and the intensity of the excitation signal and ii) the length of the n region

Physicsbusiness.industryMonte Carlo methodSemiconductor deviceComputational physicsGallium arsenideNonlinear systemchemistry.chemical_compoundSemiconductorchemistryHigh harmonic generationOptoelectronicsbusinessIntensity (heat transfer)Voltage2006 25th International Conference on Microelectronics
researchProduct

Synchronized photonic modulators driven by surface acoustic waves

2013

Photonic modulators are one of the most important elements of integrated photonics. We have designed, fabricated, and characterized a tunable photonic modulator consisting of two 180 degrees-dephased output waveguide channels, driven by a surface acoustic wave in the GHz frequency range built on (Al,Ga)As. Odd multiples of the fundamental driven frequency are enabled by adjusting the applied acoustic power. A good agreement between theory and experimental results is achieved. The device can be used as a building block for more complex integrated functionalities and can be implemented in several material platforms. (C) 2013 Optical Society of America

Physicsbusiness.industrySurface acoustic wavePhotonic integrated circuitPhysics::OpticsIntegrated optics devicesAcoustic waveModulatorsSound powerAtomic and Molecular Physics and Opticslaw.inventionÒptica Aparells i instrumentsTECNOLOGIA ELECTRONICAOpticsAcousto-optical deviceslawSurface waveTEORIA DE LA SEÑAL Y COMUNICACIONESOptoelectronicsPhotonicsbusinessWaveguideBlock (data storage)
researchProduct

Electrooptic beam deflection with latex

1988

The use of latex in electrooptic devices is proposed. The static non linearity coefficient is shown to be approximatively 200 times the optical one. The theory of a beam deflector is developed and an explicit expression is given for the deflection angle versus the physical parameters of the sample Utilisation de suspensions aqueuses de latex dans un dispositif electro-optique. On montre que le coefficient statique de non-linearite devrait etre 200 fois plus eleve que le coefficient optique. Application a un deflecteur optique

Physics::Optics02 engineering and technology01 natural sciencesDeflection angle010309 opticsOptics0103 physical scienceselectro optical effectsChemistrybusiness.industrylatexNon linearityNonlinear opticsdeflection angleParticle suspension021001 nanoscience & nanotechnologyelectrooptic devicesphysical parameterssample[PHYS.HIST]Physics [physics]/Physics archivesPhysics::Accelerator Physicsstatic nonlinearity coefficientelectrooptic beam deflection0210 nano-technologybusinessBeam (structure)electro optical devices
researchProduct

Three-dimensional cell cultures: from molecular mechanisms to clinical applications.

1997

This article reviews actual advances in the development and application of three-dimensional (3-D) cell culture systems. Recent therapeutically oriented studies include characterization of multicellular-mediated drug resistance, novel ways of quantifying hypoxia, and new approaches to more efficient immunotherapy. Recent progress toward understanding the development of necrosis in tumor spheroids has been made using novel spheroid models. 3-D cultures have been used for studies on molecular mechanisms involved in invasion and metastasis, with a major focus on the role of E-cadherin. Similarly, tumor angiogenesis and the significance of vascular endothelial growth factor have been investigat…

PhysiologyTumor spheroidCell Culture TechniquesPhysiologyEmbryoid bodyBiologyMetastasislaw.inventionchemistry.chemical_compoundlawmedicineTumor Cells CulturedAnimalsHumansCells CulturedNeovascularization PathologicSpheroidBioartificial liver deviceCell BiologyModels Theoreticalmedicine.diseaseEmbryonic stem cellCell HypoxiaVascular endothelial growth factorchemistryCell cultureDrug Resistance NeoplasmImmunotherapyNeuroscienceThe American journal of physiology
researchProduct