Search results for "diameter"

showing 10 items of 189 documents

Morphometry and comparative histology of sinus and atrioventricular nodes in humans and pigs and their relevance in the prevention of nodal arrhythmi…

2019

The cardiac conduction system is a network structure that allows the initiation and fast propagation of electrical impulses that trigger the electrical depolarization of the myocardial tissue. The purpose of this work is to study the histological and morphometric characteristics of the different components of the sinus and atrioventricular nodes in humans and pigs and their relationship with supraventricular arrhythmias. In this study, we describe the morphometry of the sinus and atrioventricular nodes of 10 adult humans and 10 pig hearts. A computerized morphometric study has been carried out, where we determined the number of cells that compose the nodes as well as different parameters re…

Swine040301 veterinary sciencesBiology0403 veterinary science03 medical and health sciencesHeart Conduction SystemmedicineAnimalsHumansdiameter [Area]Intermediate filamentsHeart AtriaHistology Comparativecardiovascular diseasesSinus (anatomy)Sinoatrial Node030304 developmental biology0303 health sciencesSupraventricular arrhythmiaGeneral VeterinaryT cellArrhythmias CardiacHistologyDepolarization04 agricultural and veterinary sciencesAnatomyAtrioventricular nodemedicine.anatomical_structureConduction systemAtrioventricular NodeP cellcardiovascular systemDesminElectrical conduction system of the heartNODALResearch in Veterinary Science
researchProduct

Experimental Tests to Validate a Simple Procedure to Design Dual-Diameter Drip Laterals on Flat Fields

2023

Multiple-diameter laterals reduce the total cost in microirrigation systems, however, the length of each sublateral should be determined carefully to assure appro-priate performance of emitter flow rates. The most accurate method is the numerical trial and error, which is time-consuming. A series of research efforts have been made to propose simple analytical design procedures. By using the power-law form of the Darcy-Weisbach formula, and equal emitters spacing for the sublaterals, Sadeghi et al. (Sadeghi et al. in J Irrig Drain E-ASCE 142:04,016,020, 2016) extended a previously introduced design solution for one-diameter laterals to tapered laterals. Recently, a simplified procedure to de…

Tapered lateralDual-diameter drip lateralSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-ForestaliAnalytical solutionsFlow rate experimental measurement
researchProduct

Evaluation of different mechanical fruit harvesting systems and oil quality in very large size olive trees

2014

In 2006 and 2009, trials were carried out in the Apulia region in Southern Italy to evalu-ate the possibility of mechanizing olive harvesting in groves of old and very large trees. The trees belonged to the cultivars ‘Cellina di Nardò’ and ‘Ogliarola Salentina’. They were 60-100 years old and 7-9 m tall with a canopy volume of 140-360 m3. In the first half of November 2006, with a mechanical beater mounted on a tractor plus hand-held pneumatic combs, the harvesting yield was close to 90% of the total olives present in the canopy, and the harvesting working productivity was around 60 kg of harvested olives h-1 worker-1. With a self-propelled shaker attached to the main branches the harvestin…

TractorCanopyQuality oilbusiness.product_categoryprotected designation of originHarvesting costMechanical beaterlcsh:AgricultureBranch shakermechanical beaterYield (wine)Botanybranch shakerOlea europaea L.; mechanical beater; pneumatic combs; branch shaker; harvesting costCultivarharvesting costdiameterMathematicsdetachment forceOlea europaea L.Crop yieldMechanical fruit harvestinglcsh:SOliveOlea europaea LBranch shaker; Harvesting cost; Mechanical beater; Olea europaea L; Pneumatic combspneumatic combsOlive treesSettore AGR/03 - Arboricoltura Generale E Coltivazioni ArboreeHorticulturePneumatic combsOil qualityAgricultural EngineeringbusinessAgronomy and Crop ScienceLarge sizeSpanish Journal of Agricultural Research
researchProduct

PM—Power and Machinery

2001

Abstract In both the OECD Code and the EC Directive for testing dual-pillar front-mounted roll-over protection structures for narrow track width tractors, a non-continuous rolling preliminary test in case of lateral overturning is provided. This test can be simulated with a computer programme. The role of the tyres (and also of the rims) in the lateral overturning of narrow tractors is very important. Frequently the same tractor can be alternatively equipped with four, five, or more different tyre combinations, which can vary its total mass, width, centre of gravity position and moment of inertia about its longitudinal axis. According to the Standards the preliminary test must be carried ou…

TractorEngineeringbusiness.product_categorybusiness.industryStructural engineeringAquatic ScienceMoment of inertiaTrack (rail transport)Greatest DiameterAutomotive engineeringPower (physics)Test (assessment)Continuous rollingLongitudinal axisbusinessJournal of Agricultural Engineering Research
researchProduct

Cryobiopsy as a New Tool for Complications Diagnosis During Follow-up After Lung Transplantation: Single Institution Case Series

2020

ABSTRACT Background The first description of performing a new diagnostic procedure, cryobiopsy, in lung transplant recipients in Poland. Methods Three cases of patients after lung transplantation were analyzed in context of the procedure of cryobiopsy, which was performed in a hybrid room with a bronchoscopic video track and C-arm radiograph. Patients were subjected to complete anesthesia and intubated. Two or three sections with an average diameter of 5 mm were collected. Results The sections were large and fully diagnostic. In all 3 described cases they brought a decisive element into diagnosis. Conclusions Cryobiopsy is a useful tool in the differential diagnosis of lesions and complicat…

Transplantationmedicine.medical_specialtyLungAverage diameterbusiness.industryBiopsyRadiographymedicine.medical_treatmentContext (language use)medicine.anatomical_structureBronchoscopyHumansMedicineLung transplantationSurgeryRadiologySingle institutionDifferential diagnosisLung Diseases InterstitialbusinessLungFollow-Up StudiesLung TransplantationRetrospective StudiesTransplantation Proceedings
researchProduct

Dynamic mechanical properties of semi-interpenetrating networks based on poly(styrene-co-maleic anhydride)

1991

Semi-interpenetrating networks based on linear anionic polystyrene (PS) and poly(styrene-co-maleic anhydride) P(ScoMA) of low MA content are prepared by crosslinking the P(ScoMA) with 4,4′-diphenylmethanediamine (DPMDA). It is demonstrated by dynamic mechanical analysis and by DSC that immiscible semi-IPN's are obtained for MA contents greater 5 wt.-%. In miscible semi-IPN's the relaxation of free PS chains is observed as a second maximum in the loss tangent at higher temperatures. The position of this maximum is shifted to higher temperatures for a polystyrene of molecular weight 500000 compared to a polystyrene of molecular weight 150000. The experimental temperature shift is in good agre…

Tube diameterMaterials sciencePolymers and PlasticsRelaxation (NMR)Analytical chemistryMaleic anhydrideGeneral ChemistryDynamic mechanical analysisCondensed Matter PhysicsStyrenechemistry.chemical_compoundchemistryMaterials ChemistryDissipation factorPolystyrenePolymer Bulletin
researchProduct

Wet-chemical approach for the cell-adhesive modification of polytetrafluoroethylene

2011

Polytetrafluoroethylene (PTFE), a frequently utilized polymer for the fabrication of synthetic vascular grafts, was surface-modified by means of a wet-chemical process. The inherently non-cell-adhesive polymer does not support cellular attachment, a prerequisite for the endothelialization of luminal surface grafts in small diameter applications. To impart the material with cell-adhesive properties a treatment with sodium-naphthalene provided a basis for the subsequent immobilization of the adhesion promoting RGD-peptide using a hydroxy- and amine-reactive crosslinker. Successful conjugation was shown with cell culture experiments which demonstrated excellent endothelial cell growth on the m…

Umbilical VeinsMaterials scienceSmall diameterPolymersSurface PropertiesCellCell Culture TechniquesBiomedical EngineeringBioengineeringNaphthalenesBiomaterialschemistry.chemical_compoundCell AdhesionmedicineHumansComposite materialPolytetrafluoroethylenechemistry.chemical_classificationPolytetrafluoroethyleneSodiumEndothelial CellsPolymerAdhesionCross-Linking Reagentsmedicine.anatomical_structureChemical engineeringchemistryCell cultureAdsorptionAdhesiveOligopeptidesEndothelial cell growthBiomedical Materials
researchProduct

Diameter 2 properties and convexity

2015

We present an equivalent midpoint locally uniformly rotund (MLUR) renorming $X$ of $C[0,1]$ on which every weakly compact projection $P$ satisfies the equation $\|I-P\| = 1+\|P\|$ ($I$ is the identity operator on $X$). As a consequence we obtain an MLUR space $X$ with the properties D2P, that every non-empty relatively weakly open subset of its unit ball $B_X$ has diameter 2, and the LD2P+, that for every slice of $B_X$ and every norm 1 element $x$ inside the slice there is another element $y$ inside the slice of distance as close to 2 from $x$ as desired. An example of an MLUR space with the D2P, the LD2P+, and with convex combinations of slices of arbitrary small diameter is also given.

Unit sphereSmall diameter46B04 46B20General Mathematics010102 general mathematicsRegular polygon01 natural sciencesMidpointConvexityFunctional Analysis (math.FA)Mathematics - Functional Analysis010101 applied mathematicsCombinatoricsNorm (mathematics)FOS: Mathematics0101 mathematicsMathematicsStudia Mathematica
researchProduct

Image Processing and Measurement of the Bubble Properties in a Bubbling Fluidized Bed Reactor

2022

The efficiency of a fluidized bed reactor depends on the bed fluid dynamic behavior, which is significantly influenced by the bubble properties. This work investigates the bubble properties of a bubbling fluidized bed reactor using computational particle fluid dynamic (CPFD) simulations and electrical capacitance tomography (ECT) measurements. The two-dimensional images (along the reactor horizontal and vertical planes) of the fluidized bed are obtained from the CPFD simulations at different operating conditions. The CPFD model was developed in a commercial CPFD software Barracuda Virtual Reactor 20.0.1. The bubble behavior and bed fluidization behavior are characterized form the bubble pro…

VDP::Teknologi: 500Control and OptimizationRenewable Energy Sustainability and the EnvironmentEnergy Engineering and Power TechnologyBuilding and ConstructionElectrical and Electronic Engineeringfluidized bed; bubble diameter; bubble rise velocity; bubble frequency; computational particle fluid dynamic; image processingEngineering (miscellaneous)Energy (miscellaneous)
researchProduct

Hierarchical imaging and computational analysis of three-dimensional vascular network architecture in the entire postnatal and adult mouse brain

2021

The formation of new blood vessels and the establishment of vascular networks are crucial during brain development, in the adult healthy brain, as well as in various diseases of the central nervous system. Here, we describe a step-by-step protocol for our recently developed method that enables hierarchical imaging and computational analysis of vascular networks in postnatal and adult mouse brains. The different stages of the procedure include resin-based vascular corrosion casting, scanning electron microscopy, synchrotron radiation and desktop microcomputed tomography imaging, and computational network analysis. Combining these methods enables detailed visualization and quantification of t…

Vessel networkBiochemistry & Molecular BiologyBrain developmentBrain vasculatureScanning electron microscopeComputer sciencePoint densityCentral nervous systemVascular volumeGenetics and Molecular BiologyINTUSSUSCEPTIVE ANGIOGENESISINHIBITS TUMOR-GROWTHTortuosityBiochemical Research MethodsSCANNING-ELECTRON-MICROSCOPYGeneral Biochemistry Genetics and Molecular BiologyBLOOD-VESSELSSPROUTING ANGIOGENESIS10180 Clinic for NeurosurgeryNEUROVASCULAR UNIT1300 General Biochemistry Genetics and Molecular Biologymedicine10237 Institute of Biomedical EngineeringComputational analysisAdult stageMICROVASCULAR NETWORKSIntussusceptive angiogenesisSprouting angiogenesisScience & TechnologySTRUCTURAL ADAPTATIONCOCHLEAR VASCULATUREMOLECULAR-MECHANISMS10177 Dermatology Clinic10081 Institute of Veterinary Physiology10124 Institute of Molecular Life SciencesVessel diametermedicine.anatomical_structureVascular network10036 Medical ClinicGeneral Biochemistry570 Life sciences; biologyLife Sciences & BiomedicinePerfusionBiomedical engineering
researchProduct