Search results for "disability evaluation"

showing 7 items of 157 documents

Design and Validation of an Expanded Disability Status Scale Model in Multiple Sclerosis.

2020

<b><i>Introduction:</i></b> We aimed to develop and validate an Expanded Disability Status Scale (EDSS) model through clinical, optical coherence tomography (OCT), and magnetic resonance imaging (MRI) measures. <b><i>Methods:</i></b> Sixty-four multiple sclerosis (MS) patients underwent peripapillary retinal nerve fiber layer and segmented macular layers evaluation through OCT (Spectralis, Heidelberg Engineering). Brain parenchymal fraction was quantified through Freesurfer, while cervical spinal cord (SC) volume was assessed manually guided by Spinal Cord Toolbox software analysis. EDSS, neuroradiological, and OCT assessment were carried out …

medicine.medical_specialtyMultiple Sclerosisgenetic structuresPhysics::Medical PhysicsNerve fiber layerOrdinal regressionRetinaExpanded disability status scale Magnetic resonance imaging Multiple sclerosis Spectral domain optical coherence tomography Spinal cordDisability EvaluationOptical coherence tomographyOphthalmologyHumansMedicineCutoffExpanded Disability Status Scalemedicine.diagnostic_testbusiness.industryMultiple sclerosisBrainMagnetic resonance imagingmedicine.diseaseSpinal cordMagnetic Resonance Imagingeye diseasesmedicine.anatomical_structureNeurologyNeurology (clinical)sense organsbusinessTomography Optical Coherence
researchProduct

Disability assessment using Google Maps.

2021

Objectives To evaluate the concordance between Google Maps® application (GM®) and clinical practice measurements of ambulatory function (e.g., Ambulation Score (AS) and respective Expanded Disability Status Scale (EDSS)) in people with multiple sclerosis (pwMS). Materials and methods This is a cross-sectional multicenter study. AS and EDSS were calculated using GM® and routine clinical methods; the correspondence between the two methods was assessed. A multinomial logistic model is investigated which demographic (age, sex) and clinical features (e.g., disease subtype, fatigue, depression) might have influenced discrepancies between the two methods. Results Two hundred forty-three pwMS were …

medicine.medical_specialtyNeurologyMultiple SclerosisConcordanceAmbulatory disordersDermatology03 medical and health sciencesDisability Evaluation0302 clinical medicineInternal medicinemedicineGoogle MapsHumans030212 general & internal medicineDepression (differential diagnoses)Ambulatory disorderFatigueNeuroradiologyExpanded Disability Status Scalebusiness.industryGeneral MedicineOdds ratioConfidence intervalSearch EnginePsychiatry and Mental healthCross-Sectional StudiesAmbulatorye-HealthOriginal ArticleNeurology (clinical)businessDigital health030217 neurology & neurosurgeryNeurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical NeurophysiologyReferences
researchProduct

Efficiency of telemedicine for acute stroke: a cost-effectiveness analysis from a French pilot study

2020

AbstractObjectivesTelestroke is an effective way to improve care and health outcomes for stroke patients. This study evaluates the cost-effectiveness of a French telestroke network.MethodsA decision analysis model was built using population-based data. We compared short-term clinical outcomes and costs for the management of acute ischemic stroke patients before and after the implementation of a telestroke network from the point of view of the national health insurance system. Three effectiveness endpoints were used: hospital death, death at 3 months, and severe disability 3 months after stroke (assessed with the modified Rankin scale). Most clinical and economic parameters were estimated fr…

medicine.medical_specialtyTelemedicineCost effectivenessCost-Benefit AnalysisPopulationPilot Projects030204 cardiovascular system & hematologyEfficiency OrganizationalState MedicineDisability Evaluation03 medical and health sciences0302 clinical medicineModified Rankin ScaleHumansMedicineHospital MortalityeducationStrokeTelerehabilitationAcute strokeeducation.field_of_studybusiness.industryHealth PolicyStroke RehabilitationCost-effectiveness analysismedicine.diseaseStrokeModels EconomicEmergency medicineFranceHealth Expendituresbusiness030217 neurology & neurosurgeryDecision analysisInternational Journal of Technology Assessment in Health Care
researchProduct

The early changes in trunk muscle strength and disability following lumbar spine fusion

2012

To analyze trunk muscle function pre- and postoperatively in patients undergoing lumbar spine fusion. Associations between changes in trunk muscle strength and disability were also studied.A total of 114 patients undergoing lumbar spine fusion participated in the study. The flexion and extension strength of the trunk was measured preoperatively and 3 months after surgery using a strain-gauge dynamometer. Disability and pain during the past week was evaluated with the Oswestry disability index (ODI) and visual analog scale (VAS), respectively.Preoperative trunk extension and flexion strength levels were 319 N and 436 N in males, respectively, and 160 N and 214 N in females, respectively. In …

musculoskeletal diseasesAdultMaleMuscle Strength Dynamometermedicine.medical_specialtyTime FactorsLumbar spine fusionVisual analogue scaleMuscle Strength DynamometerDisability EvaluationSurveys and QuestionnairesMedicineHumansDisabled PersonsMuscle StrengthProspective StudiesRange of Motion ArticularProspective cohort studyMuscle SkeletalAgedPain MeasurementPain PostoperativeLumbar Vertebraebusiness.industryRehabilitationTorsota3141Recovery of FunctionTorsoMiddle AgedTrunkSurgeryOswestry Disability Indexmedicine.anatomical_structureSpinal FusionTreatment OutcomeBack PainFemalebusinessRange of motionFollow-Up StudiesDisability and Rehabilitation
researchProduct

The PROMISE study protocol: a multicenter prospective study of process optimization with interdisciplinary and cross-sectoral care for German patient…

2021

Background and purpose — Knee and hip replacement are common and increasing procedures, and an optimized care process that could be implemented in different settings would be useful. The PROMISE trial investigates whether a new care process works equally in different German settings and how the results compare with current non-standardized care. Patients and methods — This multi-center prospective mixed-method study includes 2,000 German patients receiving arthritis-related hip or knee endoprostheses. An interdisciplinary and cross-sectoral care process was developed and implemented in 3 German hospitals with different levels of care, and corresponding rehabilitation centers were included t…

musculoskeletal diseasesmedicine.medical_specialtyCare processArthroplasty Replacement HipMEDLINEHip replacement (animal)German03 medical and health sciencesDisability Evaluation0302 clinical medicineGermanySurveys and QuestionnairesmedicineHumansOrthopedics and Sports Medicine030212 general & internal medicineProspective StudiesProspective cohort studyArthroplasty Replacement KneePain MeasurementProtocol (science)Orthopedic surgeryPatient Care Team030222 orthopedicsbusiness.industryGeneral MedicineProstheses and Implantslanguage.human_languageTreatment OutcomeCross sectorallanguagePhysical therapyQuality of LifeSurgerybusinessRD701-811Research ArticleActa Orthopaedica
researchProduct

A scoping review on how physical fitness is evaluated in sitting volleyball players

2023

Introduction: Sitting volleyball is a widely practiced paralympic sport. A correct and standardized physical evaluation helps coaches to plan and manage the training. It is also important to evaluate physical fitness accurately and adopt standardized protocols to compare and normalize the data. The aim of the study was to evaluate physical fitness evaluation methods adopted in sitting volleyball and to eventually propose standard operating procedures. Evidence acquisition: English-written and peer-reviewed original articles were included in this review. The population studied was composed only of athletes practicing sitting volleyball. Articles were searched on the electronic databases PubM…

operativeSurgical proceduresDisability evaluationPhysical Therapy Sports Therapy and RehabilitationOrthopedics and Sports MedicineSOP evaluation disabilityStandard operating procedureSportsThe Journal of Sports Medicine and Physical Fitness
researchProduct

Optical quality of hyperopic and myopic phakic intraocular lenses

2013

Aims: To assess and compare the optical quality of the myopic and hyperopic implantable collamer lens (ICL) from its wavefront aberrations for different powers and pupil diameters. Settings and Design: Prospective study. Material and Methods: The wavefront aberrations of two myopic (−3 and −6 diopters (D)) and two hyperopic V4b ICLs (+3 and +6D) were measured in vitro . To assess and compare the optical quality of different powers of ICLs, we analyzed the root mean square (RMS) of total higher order aberrations (HOAs), trefoil, coma, tetrafoil, secondary astigmatism, and spherical aberration at 3- and 4.5-mm pupil. In addition, the point spread functions (PSFs) of each ICL evaluated were ca…

steep corneal curvatureintravitreallacrimal fossaRefractive errorvisual acuitygenetic structurespterygium surgerystandard automated perimetryComa (optics)BlindnessPhakic intraocular lenslaw.inventionsubconjunctival bevacizumab injectionCorneaLens Implantation Intraocularlcsh:Ophthalmologylawmodified deep anterior lamellar keratoplastyMitomycin CMaterials TestingAutogenous tissue graftingProspective StudiesDioptreoptical qualityshort wave automated perimetryexcimer lasernon-proliferative diabetic retinopathyMean deviationin vitroheavy silicone oilBevacizumabLens (optics)Aberrations of the eyeSpherical aberrationHyperopiaAntimicrobial effectOriginal ArticleTriamcinolone acetonidehuman trabecular meshwork cellsPhakic Intraocular Lensesmedicine.medical_specialtyImaging in glaucomadisability evaluationconventional silicone oiltriamcinoloneProsthesis DesignKeratoconusphotorefractive keratectomyOphthalmologygrowth factorsmedicineHumansmyopiamyopic implantable collamer lensshort fluctuationsWavefrontmacular edemaoptical coherence tomographyendophthalmitis agentsbusiness.industrybranch retinal vein occlusionretinal nerve fiber layerpterygium recurrencemedicine.diseaseeye diseasesOphthalmologypediatricwavefront aberrationsquality of lifelcsh:RE1-994bypass surgeryHyperopic implantable collamer lenslacrimal drainage systemsense organsbusinessIndian Journal of Ophthalmology
researchProduct