Search results for "discharge"
showing 10 items of 424 documents
Partial discharge detection and localization along medium voltage cables
2017
In the last years different partial discharge (PD) measuring techniques have been developed because PD diagnostic is the most widely tool to evaluate the insulation condition of a power cable. Recently non-conventional methods and sensors have been used in order to reach improved results in PD measurements. The purpose of this work is to perform measurements that allow to study the variation of pulses when they travel along a MV cable and to locate the pulse source through the time arrival difference of the pulses obtained from two sensors installed separately.
Psychological experience of patients 3 months after a stay in the intensive care unit: A descriptive and qualitative study.
2015
Abstract Purpose The purpose was to describe psychological experiences of patients 3 months after a stay in the intensive care unit (ICU) using qualitative methods. Methods Twenty patients underwent clinical interview lasting 1 hour and completed the Impact of Event Scale—Revised and Hospital Anxiety and Depression questionnaires. All interviews were recorded and coded using thematic analysis. Results All patients (100%) reported that they could not remember their ICU stay; half reported confused memories (50%) or disorientation (50%). Negatives memories were also reported (20%-45%), namely, pain, distress, sleep difficulties, noise, fear, feeling of abandonment; 20% reported positive memor…
Evaluation and improvement of the quality of the discharge prescription in Cystic Fibrosis children hospitalised for intravenous antibiotic therapy
2017
1.Antecedentes. La Fibrosis Quística (FQ) es una enfermedad conocida desde la edad media, aunque durante esa época no estaba descrita como tal sino más bien como un hechizo maligno. En 1943, Farber propuso el término mucoviscidosis y este término se sigue utilizando en la actualidad. La FQ es la enfermedad hereditaria autosómica recesiva grave más frecuente en la población blanca, con una incidencia en Europa que oscila entre 1:1.353 en Irlanda y entre 1:25.000 en Finlandia, y una frecuencia de portadores de 1 por cada 2527. Es una enfermedad de las células epiteliales exocrinas, que se caracteriza por la producción de un moco espeso y viscoso que obstruye los conductos del órgano donde se …
Enhanced tonic GABAA inhibition in typical absence epilepsy
2009
The cellular mechanisms underlying typical absence seizures, which characterize various idiopathic generalized epilepsies, are not fully understood, but impaired γ-aminobutyric acid (GABA)-ergic inhibition remains an attractive hypothesis. In contrast, we show here that extrasynaptic GABAA receptor–dependent 'tonic' inhibition is increased in thalamocortical neurons from diverse genetic and pharmacological models of absence seizures. Increased tonic inhibition is due to compromised GABA uptake by the GABA transporter GAT-1 in the genetic models tested, and GAT-1 is crucial in governing seizure genesis. Extrasynaptic GABAA receptors are a requirement for seizures in two of the best character…
Home treatment of patients with low-risk pulmonary embolism with the oral factor Xa inhibitor rivaroxaban: Rationale and design of the HoT-PE Trial
2016
SummaryPulmonary embolism (PE) is a potentially life-threatening acute cardiovascular syndrome. However, more than 95 % of patients are haemodynamically stable at presentation, and among them are patients at truly low risk who may qualify for immediate or early discharge. The Home Treatment of Pulmonary Embolism (HoT-PE) study is a prospective international multicentre single-arm phase 4 management (cohort) trial aiming to determine whether home treatment of acute lowrisk PE with the oral factor Xa inhibitor rivaroxaban is feasible, effective, and safe. Patients with confirmed PE, who have no right ventricular dysfunction or free floating thrombi in the right atrium or ventricle, are eligib…
High-Speed Machines: Typologies, Standards, and Operation under PWM Supply
2018
This paper presents an overview of the most recent state of the art in the field of high-speed electric machines fed through high-frequency converters. This type of systems is rapidly wide spreading in aeronautical and automotive applications, as well as microturbines. Each typology has its own advantages and downsides, which are analytically presented in this paper. Some types of high-speed electric machines require high-frequency voltage supply, highly stressing the dielectric materials of the winding insulation system. For this reason, in high-speed electric drives, premature failure may occur and a reduction of the total system reliability has been observed in the past years. Such issue…
Partial Discharge on-line measures in cable's EPR insulation
2004
In this paper, an experimental study, carried out on an operating MV cable, is presented. The aim is to identify, locate and characterize defects in the cable's EPR (ethylene-propylene copolymer rubber) insulation. Direct partial discharge measurements have been compared to those obtained by high frequency electromagnetic field measures. The latter have been carried out using a sensor which does not require any galvanic connection with the system under test and that performs an intrinsic localization of the defect. Moreover, an analysis of an MV cable junction has been carried out using the same tools.
Field Testing of a Simple Flume (SMBF) for Flow Measurement in Open Channels
2008
In this paper the stage–discharge relationship of a new flume named SMBF (Samani, Magallanex, Baiamonte, Ferro), originally proposed by Samani and Magallanez and tested by Baiamonte and Ferro, for measuring flow discharge in open channels is reviewed. The flume is obtained inserting two semicylinders in a rectangular cross section. The results of some experimental runs carried out using horizontal flumes characterized by different values of the contraction ratio (ranging from 0.17 to 0.81) are used for determining the two coefficients of the power stage–discharge equation. The stage–discharge equation is tested using flow measurements carried out in the period between December 2004 and Marc…
Study Regarding Process of the Electrical Discharge Machining with Magnetic Activation of the Welded Joints of some Materials High Alloy Steel
2021
The scientific paper presents an extensive research on modeling and optimizing the technological parameters of the process for processing by processing electric discharges with massive electrode with and without magnetic activation. Scientific research is based on real data collected from the process of electrical discharges performed on various samples extracted from areas of welded joints of metal components made of high alloy steel. The processing of experimental data was performed both classically and actively, especially the method of the central factorial experiment composed of orthogonal and rotary. The process parameters that were initially modeled and subsequently optimized were ba…
Usefulness of Clinical Data and Biomarkers for the Identification of Frailty After Acute Coronary Syndromes
2015
Abstract Background Frailty predicts mortality after acute coronary syndrome (ACS). The standard frailty scales, such as the Fried score, consist of a variety of questionnaires and physical tests. Our aim was to investigate easily available clinical data and blood markers to predict frailty at discharge, in elderly patients after ACS. Methods A total of 342 patients older than 65 years, survivors after ACS, were included. A high number of clinical variables were collected. In addition, blood markers potentially linked to frailty and related to the processes of inflammation, coagulation, hormonal dysregulation, nutrition, renal dysfunction, and heart dysfunction were determined. Frailty was …