Search results for "discharge"

showing 10 items of 424 documents

Role of IP3 Receptors in Shaping the Carotid Chemoreceptor Response to Hypoxia but not to Hypercapnia in the Rat Carotid Body: An Evidence Review

2021

This article addresses the disparity in the transduction pathways for hypoxic and hypercapnic stimuli in carotid body glomus cells. We investigated and reviewed the experimental evidence showing that the response to hypoxia, but not to hypercapnia, is mediated by 1,4,5-inositol triphosphate receptors (IP3R/s) regulating the intracellular calcium content [Ca2+]c in glomus cells. The rationale was based on the past observations that inhibition of oxidative phosphorylation leads to the explicit inhibition of the hypoxic chemoreflex. [Ca2+]c changes were measured using cellular Ca2+-sensitive fluorescent probes, and carotid sinus nerve (CSN) sensory discharge was recorded with bipolar electrode…

Carotid sinus nerveHypercapniaCarotid bodyHypoxia IP3 receptorPhosphoinositidesChemosensory dischargeGlomus cellsCarotid chemoreceptor responses
researchProduct

Experimental Study of Central Baffle Flume

2019

In this paper, the hydraulics of a central baffle flume (CBF) were experimentally studied. Extensive experimental runs were carried out to highlight the effects of different geometrical parameters such as baffle length, contraction ratio, and the length of upstream and downstream guide walls. Two different approaches, i.e., the Π theorem of dimensional analysis coupled with the incomplete self-similarity theory and the energy balance equation, were applied to deduce the stage–discharge formula of a CBF characterized by different geometrical parameters. The stage–discharge relationship deduced by the dimensional analysis approach was more accurate than that obtained by the energy approach. F…

Central baffle flumeHydraulicsOptimal design of CBFStage–discharge formula0207 environmental engineeringBaffle02 engineering and technology01 natural sciencesAgricultural and Biological Sciences (miscellaneous)Buckingham’s theoremlaw.invention010309 opticsFlumelaw0103 physical sciencesSettore AGR/08 - Idraulica Agraria E Sistemazioni Idraulico-Forestali020701 environmental engineeringIncomplete self-similarityGeologyWater Science and TechnologyCivil and Structural EngineeringMarine engineering
researchProduct

Isovaleraldehyde degradation using UV photocatalytic and dielectric barrier discharge reactors, and their combinations

2015

International audience; The abatement of isovaleraldehyde present in air was carried out in UV photocatalytic and dielectric barrier discharge reactors (and their combinations) for concentrations up to 150 mg C m−3 and air flow rates ranging from 4 to 10 m3 h−1. A kinetic study was performed following a Langmuir–Hinshelwood model. Photocatalytic treatment of an isovaleraldehyde and isovaleric acid mixture showed a clear inhibition of isovaleric acid abatement in presence of isovaleraldehyde. Dielectric barrier discharge treatment of isovaleraldehyde showed an increase of removal efficiency with applied voltage and a decrease with air flow rate and inlet concentration. Moreover, introduction…

ChromatographyChemistryGeneral Chemical EngineeringInorganic chemistryDielectric barrier discharge treatmentGeneral Physics and AstronomyGeneral ChemistryDielectric barrier dischargeQuímicaUV photocatalytic reactor6. Clean waterIsovaleraldehydeCatalysischemistry.chemical_compoundCombined treatment[CHIM.GENI]Chemical Sciences/Chemical engineeringCoupled systemAir flow ratePhotocatalysisDegradation (geology)Hybrid reactorHybrid reactorEnginyeria ambientalVOC removal
researchProduct

The effect of geometrical parameters on the discharge capacity of meandering compound channels

2008

A number of methods and formulae has been proposed in the literature to estimate the discharge capacity of compound channels. When the main channel has a meandering pattern, a reduction in the conveyance capacity for a given stage is observed, which is due to the energy dissipations caused by the development of strong secondary currents and to the decrease of the main channel bed slope with respect to the valley bed slope. The discharges in meandering compound channels are usually assessed applying, with some adjustments, the same methods used in the straight compound channels. Specifically, the sinuosity of the main channel is frequently introduced to account for its meandering pattern, al…

Compound channels Meanders Sinuosity Stage—discharge curves Numerical simulationHydrologyMean curvatureComputer simulationTurbulenceGeometrySinuosityRadiusDissipationSettore ICAR/01 - IdraulicaReynolds-averaged Navier–Stokes equationsGeologyComputer Science::Information TheoryWater Science and TechnologyCommunication channelAdvances in Water Resources
researchProduct

A new approach to partial discharge detection under DC voltage

2018

The continuing development of HVDC power transmission systems presents many problems related to evaluation of the reliability of power system assets [1]-[5]. In this context the identification of insulation defects plays a key role in preventing unexpected failures of electrical components. Partial discharge (PD) measurement is a useful approach to assessing the condition of HV power apparatus and cables. Such measurements are also widely employed for HVAC systems. The inception mechanisms of PD in AC systems are well-known, and measurements are usually performed following the IEC 60270 standard [6]. PD measurements under DC voltage present complexities related to the nature of the phenomen…

Computer science020209 energyContext (language use)DC measurement02 engineering and technology01 natural sciencesElectric power systemReliability (semiconductor)0103 physical sciencesHVAC0202 electrical engineering electronic engineering information engineeringElectrical and Electronic Engineering010302 applied physicsPower transmissiondischargephenomenaHVDCbusiness.industrytesting methodElectronic Optical and Magnetic Materialpattern recognitionElectronic Optical and Magnetic MaterialsReliability engineeringpartial dischargeSettore ING-IND/31 - Elettrotecnicavisual_artPattern recognition (psychology)Partial dischargeElectronic componentvisual_art.visual_art_mediumbusiness
researchProduct

The possibilities of using the acoustic emission method in expert systems for the evaluation of insulation systems of power transformers

2006

The paper presents the range and possibilities of using expert systems at diagnostic measurements of insulation systems of power appliances taken by the acoustic emission (AE) method. Multi-parametric descriptors characterizing the AE signals, which can be used in the knowledge base as criteria making the identification of basic partial discharge forms (PDs) possible, have been characterized in detail. The tables show descriptors describing the AE signals registered in time, frequency, time-frequency domains and statistical data. Moreover, computational tools that can be used in the process of conclusion drawing were suggested and the range of the research work done by the authors of the pa…

Computer sciencebusiness.industryProcess (computing)General Physics and Astronomycomputer.software_genreExpert systemPower (physics)Identification (information)Acoustic emissionKnowledge basePartial dischargeElectronic engineeringRange (statistics)businesscomputerJournal de Physique IV (Proceedings)
researchProduct

An improved MSD-based method for PD defects classification

2006

The new proposed method of pattern recognition is based on the application of Multi-resolution Signal Decomposition (MSD) technique of wavelet transform. This technique has showed off interesting properties in capturing the embedded horizontal, vertical and diagonal variations within an image obtained from the PD pattern in a separable form. This feature was exploited to identify in the PD pattern's MSD, relative at various family of partial discharge sources, some detail images typical of a single discharge phenomenon. The classification of a generic PD phenomenon is feasible through a comparison between its detail images and the detail images typical of a single discharge phenomenon. Test…

Contextual image classificationbusiness.industryComputer scienceElectronic Optical and Magnetic MaterialDiagonalFeature extractionWavelet transformPattern recognitionCondensed Matter PhysicSignalpartial dischargeSettore ING-IND/31 - Elettrotecnicawavelet transform.Pattern recognition (psychology)Partial dischargeElectronic engineeringFeature (machine learning)Artificial intelligencebusiness2006 IEEE 8th International Conference on Properties & applications of Dielectric Materials
researchProduct

An experimental investigation on two different methods for swirl induction in a multivalve engine

2005

This paper describes an experimental investigation aimed at comparing the swirl effect induced by unbalancing the mass flow through the two intake ports of a multivalve engine head using two different methods: the first one reduced the curtain area of one of the intake valves [different lifts (DL) method]; the second one adopted a sluice-gate-shaped valve, installed upstream of the intake valves [swirl control valve (SCV) method] in order to cause a pressure drop. A steady-flow test rig (equipped with instrumentation for the discharge coefficient and swirl intensity measurement) was realized in order to compare and evaluate the results of both methods and determine their respective validit…

Control valvesPressure dropMechanical EngineeringMass flowTest rigAnalytical chemistryAerospace EngineeringOcean EngineeringMechanicsDischarge coefficientLift (force)Settore ING-IND/08 - Macchine A FluidoCylinder headAutomotive Engineeringswirl induction multivalve engine DL method SCV methodExperimental methodsMathematics
researchProduct

Global Frequency and Geographical Distribution of Nighttime Streamer Corona Discharges (BLUEs) in Thunderclouds

2021

This is an open access article under the terms of the Creative Commons Attribution-NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.

Corona discharges010504 meteorology & atmospheric sciencesMeteorologyDistribution (number theory)BluesThunderstorms01 natural sciencesLightningLightningUpper troposphereGeophysics13. Climate action0103 physical sciencesThunderstormGeneral Earth and Planetary SciencesStreamer coronaEnvironmental science010303 astronomy & astrophysics0105 earth and related environmental sciences
researchProduct

Electromagnetic Full-Wave Simulation of Partial Discharge Detection in High Voltage AC Cables

2019

Partial discharge (PD) activity in the insulation system of an electrical equipment can determine the failure of the whole apparatus. PD sensors are widely used in high-voltage electrical systems as the main elements of a detecting system oriented to real time monitoring. Recently, non-invasive sensors have been proposed in industrial applications for cable and other sensitive electrical parts: they are based both on capacitive and on the electromagnetic radiating coupling. In order to assess the real performance of a new sensor produced by a high voltage AC cables manufacturer, the paper proposes electromagnetic fullwave simulation results.

CouplingMaterials sciencebusiness.industryCapacitive sensingElectrical engineeringHigh voltageHardware_PERFORMANCEANDRELIABILITYelectric field distributionFinite element methodpartial dischargeSettore ING-IND/31 - ElettrotecnicaFinite Element AnalysiHardware_GENERALElectrical equipmentInsulation systemPartial dischargeHardware_INTEGRATEDCIRCUITSbusinessXLPE cableVoltage
researchProduct