Search results for "door"
showing 10 items of 376 documents
Ventilation Rates and Unsatisfied Percentage from Indoor CO2 Concentration
2010
This work reports the results of a survey carried out on a hall in a historic building in Palermo (Italy) with the aim of assessing the air quality by means of objective measurement of carbon dioxide (CO2) concentration and its subjective evaluation through a questionnaire. The measured values of CO2 concentration were compared with those evaluated using the Meckler equation under steady-state conditions, having verified necessary parameters such as the constancy of the indoor and outdoor CO2 levels and the uniformity of the CO 2 generation rate for all the occupants. The positive correspondence between measured and calculated results allowed us to utilise, under differing circumstances, t…
THE OPTIMUM SELECTION OF THE WINDOW SHADING LEVELS AND OF THE INDOOR VENTILATION RATES AS A DESIGN STRATEGY FOR BIOCLIMATIC COMMERCIAL BUILDINGS
1991
ABSTRACT Ventilation rates, shading level of windows and indoor air temperature are analyzed together in order to single out the optimum mix referred to the thermal comfort situations of thermally moderate commercial buildings. Thermal comfort is here taken into account by means of the Predicted Mean Vote ( Fanger, 1970 ). A short selection of graphs is proposed, able to provide the simultaneous view of the effects produced, on the PMV, by modifications of the above cited parameters. Graphs can be usefully adopted for the proper design of the glazed surfaces, especially for passive solar buildings.
Occupational hygiene in a waste incineration plant
2003
Abstract The Turku incineration plant was renovated in 1995 to meet the emission requirements of modern waste combustion facilities. It treats presorted municipal waste from 170,000 residents in the Turku area. In the plant, the incineration process produces several types of by-products having importance in terms of occupational hygiene. Although not obligated by the law, the management of the plant has a keen interest in occupational hygiene at the plant, which was studied from 1998 to 2001. Concentrations of microbes, endotoxins, and dust and the noise level were investigated in three different working areas. Microbe measurements were conducted with a six-stage impactor and using the CAMN…
A comparative study on the quality of air in offices and homes.
2013
The main purpose of this study was to collect data on some of the factors that contribute to indoor air quality and to discomfort, in order to take the proper actions that can reduce the level of air pollution within houses and offices. To ascertain the contamination degree total bacterial counts, total fungal counts, suspended particulate matter, air temperature, and relative humidity have been determined. Additionally, mathematical statistical models have been elaborated for the total bacterial count, respirable particulate matter and humidity. A total number of 40 indoor air samples were collected from office and houses. The results shows that approximately 45% of the air samples from ho…
Research on ecological design to enhance comfort in open spaces of a city (Valencia, Spain). Utility of the physiological equivalent temperature (PET)
2013
For many years now, research has focused on issues concerning making cities easier to live in and some of the most important of these concern climatology and thermal comfort issues. There is also a growing awareness of the importance of open spaces and green areas, as key elements in providing opportunities for human interaction, leisure and physical exercise. They are important for all inhabitants, but particularly so for children and the elderly population. Of especial interest are the studies which have examined the interaction of comfort with the urban climate. This issue was studied throughout the twentieth century, but recently the role which can be played by biometeorological indices…
The distribution of phthalate esters in indoor dust of Palermo (Italy).
2013
In this work, phthalic acid esters (PAEs): dimethyl phthalate (DMP), diethyl phthalate (DEP), di-n-butyl phthalate, benzyl butyl phthalate, bis(2-ethylhexyl) phthalate, and di-n-octyl phthalate in indoor dust (used as passive sampler) were investigated. The settled dust samples were collected from thirteen indoor environments from Palermo city. A fast and simple method using Soxhlet and GC–MS analysis has been optimized to identify and quantify the phthalates. Total phthalates concentrations in indoor dusts ranged from 269 to 4,831 mg/kg d.w. (d.w. = dry weight). The data show a linear correlation between total PAEs concentration and a single compound content, with the exclusion of the two …
Assessing the effectiveness of green roofs in enhancing the energy and indoor comfort resilience of urban buildings to climate change: Methodology pr…
2021
Abstract The effects of climate change on the built environment represents an important research challenge. Today, green roofs (GRs) represent a viable solution for enhancing energy and urban resilience in the face of climate change, as they can have a positive impact on the building's indoor thermal comfort and energy demand, as well as inducing various environmental benefits (easing urban heat island effects, improving the management of runoff water, reducing air pollution, etc.). Thus, it is important to be able to assess their effectiveness, both today and under future climate conditions, in order to evaluate whether they can also provide a valid long-term solution. In this paper, a sim…
Exposure to bioaerosols and noise at a Finnish dry waste treatment plant
2004
Repeated measurements were carried out during two different campaigns between 1998 and 2001 to assess the occupational hygiene at a Finnish dry waste treatment plant. The analytical determinations were done in four different places within the processing hall of the plant: near a conveyor belt, near a jigger screen, near an after-crusher and near a bailer. Measurements were also carried out in a coffee room for employees. Concentrations of bacteria, fungi and actinomycetes were determined by two methods (six-stage impactor and Camnea method) and levels of endotoxins, dust and noise were also investigated. High concentrations of microbes and endotoxins and the noise level were found to be a …