Search results for "doppler effect"
showing 10 items of 148 documents
Reference values of fetal aortic flow velocity waveforms and associated intra-observer reliability in normal pregnancies
2001
Objectives It was the aim of the present study to calculate new Doppler reference ranges for blood flow velocities (Vmax, Vmean, Vmin) and resistance indices (PI, RI) for the fetal descending aorta by automatic waveform analysis. Design Cross-sectional prospective study. Subjects Nine hundred and twenty-six low-risk pregnancies at 18–41 weeks' gestation. Methods Aortic blood flow velocities were derived with pulsed-wave color Doppler. Measurements were carried out at the level of the diaphragm. Reference ranges for the individual measuring parameters were constructed based on a growth function from a four-parameter class of monotonic continuous functions according to the smallest square pri…
Modelling and Analysis of Nonstationary Vehicle-to-Infrastructure Channels with Time-Variant Angles of Arrival
2018
In mobile radio channel modelling, it is generally assumed that the angles of arrival (AOAs) are independent of time. This assumption does not in general agree with real-world channels in which the AOAs vary with the position of a moving receiver. In this paper, we first present a mathematical model for the time-variant AOAs. This model serves as the basis for the development of two nonstationary multipath fading channels models for vehicle-to-infrastructure communications. The statistical properties of both channel models are analysed with emphasis on the time-dependent autocorrelation function (ACF), time-dependent mean Doppler shift, time-dependent Doppler spread, and the Wigner-Ville sp…
Why Have Many of the Brightest Radio-loud Blazars Not Been Detected in Gamma-Rays by Fermi?
2015
We use the complete MOJAVE 1.5 Jy sample of active galactic nuclei (AGNs) to examine the gamma-ray detection statistics of the brightest radio-loud blazars in the northern sky. We find that 23% of these AGNs were not detected above 0.1 GeV by the Fermi-LAT during the four-year 3FGL catalog period partly because of an instrumental selection effect and partly due to their lower Doppler boosting factors. Blazars with synchrotron peaks in their spectral energy distributions located below 10^(13.4) Hz also tend to have high-energy peaks that lie below the 0.1 GeV threshold of the LAT, and are thus less likely to be detected by Fermi. The non-detected AGNs in the 1.5 Jy sample also have significa…
Doppler Estimation and Correction for JANUS Underwater Communications
2020
In recent years, underwater communications have seen a growing interest pushed by marine research, oceanography, marine commercial operations, offshore oil industry and defense applications. Generally, underwater communications employ audio signals which can propagate relatively far but are also significantly affected by Doppler distortions. In fact, physical properties of the water and spatial changes due to tides, currents and waves can cause channel variations or unwanted movements of the transmitter or receiver. This study shows how to compensate for the Doppler effect in transmission employing the JANUS standard, a popular modulation scheme for underwater communication. Differently for…
LASCA and PPG imaging for non-contact assessment of skin blood supply
2013
Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging (LDPI). Photoplethysmography (PPG) is well known technique for assessment of skin blood pulsations that can be related to blood flow. In recent years several studies have been done on development of non-contact PPG imaging (PPGI). LASCA and PPGI techniques are simpler and cheaper compared with LDPI. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new i…
The automated assesment of artery hemodynamic parameters from ultrasound video
2012
The custom designed video processing software for analysis of B-mode and Doppler-mode ultrasound video has been proposed in this work. The software allows adjusting user-defined thresholds and tolerance levels to enhance contour detection in noisy and artifacted ultrasound images. The developed software is able to evaluate 16 hemodynamic parameters (artery diameter, pulse rate and flow velocity related parameters) in each cardiac cycle. The measurements were performed intermittently recording artery diameter (B-mode) and flow velocity (Doppler-mode). Software has validated in femoral artery measurements. The hemodynamic parameters computed by software were consistent with those obtained by …
Comparison between doppler-echocardiography and uncalibrated pulse contour method for cardiac output measurement. a multicenter observational study
2016
Objectives: Echocardiography and pulse contour methods allow, respectively, noninvasive and less invasive cardiac output estimation. The aim of the present study was to compare Doppler echocardiography with the pulse contour method MostCare for cardiac output estimation in a large and nonselected critically ill population. Design: A prospective multicenter observational comparison study. Setting: The study was conducted in 15 European medicosurgical ICUs. Patients: We assessed cardiac output in 400 patients in whom an echocardiographic evaluation was performed as a routine need or for cardiocirculatory assessment. Interventions: None. Measurements and Main Results: One echocardiographic car…
On the spectral moments of non-WSSUS mobile-to mobile double-Rayleigh fading channels
2017
This paper deals with the mathematical analysis of the spectral moments of non-wide-sensestationary uncorrelated-scattering (non-WSSUS) mobile-to-mobile (M2M) double-Rayleigh fading channels. The point of departure is a recently proposed geometry-based statistical model (GBSM) for M2M double-Rayleigh fading channels from which general analytical expressions are derived for the average Doppler shift, Doppler spread, average delay, and delay spread. Closed-form solutions of such expressions are presented for the particular case of the geometrical two-rings scattering model. The obtained results indicate that the average Doppler shift and Doppler spread are directly influenced by not only the …
A Trajectory-Driven 3D Channel Model for Human Activity Recognition
2021
This paper concerns the design, analysis, and simulation of a 3D non-stationary channel model fed with inertial measurement unit (IMU) data. The work in this paper provides a framework for simulating the micro-Doppler signatures of indoor channels for human activity recognition by using radiofrequency-based sensing technologies. The major human body segments, such as wrists, ankles, torso, and head, are modelled as a cluster of moving point scatterers. We provide expressions for the time variant (TV) speed and TV angles of motion based on 3D trajectories of the moving person. Moreover, we present mathematical expressions for the TV Doppler shifts and TV path gains associated with each movin…
High-resolution photoacoustic Raman spectroscopy of gases
1992
A high-resolution photoacoustic Raman spectroscopy experiment is described. The resolution achieved by using two single-mode pulsed lasers is about 0.0054 cm −1 (full width at half maximum intensity). The experiment was tested first on the v 1 /2v 2 bands of CO 2 and gave an increase of at least about one order of magnitude in the signal-to-noise ratio with respect to stimulated Raman spectroscopy at low pressure (ca. 10 Torr ≃ 1.3 kPa). The sensitivity is also demonstrated by the study of the weak hot band v 1 +v 2 −v 2 of CO 2 . In both cases, the experimental line shape is well reproduced by taking into account Doppler and collisional effects. A comparison with CARS spectra was also made