Reference values of fetal aortic flow velocity waveforms and associated intra-observer reliability in normal pregnancies

2001

Objectives It was the aim of the present study to calculate new Doppler reference ranges for blood flow velocities (Vmax, Vmean, Vmin) and resistance indices (PI, RI) for the fetal descending aorta by automatic waveform analysis. Design Cross-sectional prospective study. Subjects Nine hundred and twenty-six low-risk pregnancies at 18–41 weeks' gestation. Methods Aortic blood flow velocities were derived with pulsed-wave color Doppler. Measurements were carried out at the level of the diaphragm. Reference ranges for the individual measuring parameters were constructed based on a growth function from a four-parameter class of monotonic continuous functions according to the smallest square pri…

Aortic archmedicine.medical_specialtyDuplex ultrasonographyAortaRadiological and Ultrasound Technologybusiness.industryObstetrics and GynecologyHemodynamicsGeneral MedicineBlood flowSurgerysymbols.namesakemedicine.anatomical_structureReproductive MedicineInternal medicinemedicine.arteryDescending aortaVascular resistancemedicinesymbolsCardiologyRadiology Nuclear Medicine and imagingbusinessDoppler effectUltrasound in Obstetrics and Gynecology
researchProduct

Modelling and Analysis of Nonstationary Vehicle-to-Infrastructure Channels with Time-Variant Angles of Arrival

2018

In mobile radio channel modelling, it is generally assumed that the angles of arrival (AOAs) are independent of time. This assumption does not in general agree with real-world channels in which the AOAs vary with the position of a moving receiver. In this paper, we first present a mathematical model for the time-variant AOAs. This model serves as the basis for the development of two nonstationary multipath fading channels models for vehicle-to-infrastructure communications. The statistical properties of both channel models are analysed with emphasis on the time-dependent autocorrelation function (ACF), time-dependent mean Doppler shift, time-dependent Doppler spread, and the Wigner-Ville sp…

Article SubjectComputer Networks and CommunicationsComputer science02 engineering and technologylcsh:Technologylcsh:Telecommunicationsymbols.namesake0203 mechanical engineeringPosition (vector)lcsh:TK5101-67200202 electrical engineering electronic engineering information engineeringElectrical and Electronic EngineeringComputer Science::Information TheoryBasis (linear algebra)lcsh:TAutocorrelationEmphasis (telecommunications)020302 automobile design & engineering020206 networking & telecommunicationsVehicle to infrastructuresymbolsDoppler effectAlgorithmMultipath propagationInformation SystemsCommunication channelWireless Communications and Mobile Computing
researchProduct

Why Have Many of the Brightest Radio-loud Blazars Not Been Detected in Gamma-Rays by Fermi?

2015

We use the complete MOJAVE 1.5 Jy sample of active galactic nuclei (AGNs) to examine the gamma-ray detection statistics of the brightest radio-loud blazars in the northern sky. We find that 23% of these AGNs were not detected above 0.1 GeV by the Fermi-LAT during the four-year 3FGL catalog period partly because of an instrumental selection effect and partly due to their lower Doppler boosting factors. Blazars with synchrotron peaks in their spectral energy distributions located below 10^(13.4) Hz also tend to have high-energy peaks that lie below the 0.1 GeV threshold of the LAT, and are thus less likely to be detected by Fermi. The non-detected AGNs in the 1.5 Jy sample also have significa…

AstrofísicaActive galactic nucleusmedia_common.quotation_subjectAstrophysics::High Energy Astrophysical Phenomenajets [galaxies]AstrophysicsAstrophysics::Cosmology and Extragalactic Astrophysicsgeneral [gamma-ray burst]7. Clean energy01 natural scienceslaw.inventionsymbols.namesakelaw0103 physical sciencesBlazar010303 astronomy & astrophysicsAstrophysics::Galaxy Astrophysicsmedia_commonPhysicsgeneral [quasars]010308 nuclear & particles physicsScatteringSpectral densityAstronomy and Astrophysicsgalaxies [radio continuum]Synchrotron13. Climate actionSpace and Planetary ScienceSkyactive [galaxies]AstronomiasymbolsDoppler effectFermi Gamma-ray Space Telescope
researchProduct

Doppler Estimation and Correction for JANUS Underwater Communications

2020

In recent years, underwater communications have seen a growing interest pushed by marine research, oceanography, marine commercial operations, offshore oil industry and defense applications. Generally, underwater communications employ audio signals which can propagate relatively far but are also significantly affected by Doppler distortions. In fact, physical properties of the water and spatial changes due to tides, currents and waves can cause channel variations or unwanted movements of the transmitter or receiver. This study shows how to compensate for the Doppler effect in transmission employing the JANUS standard, a popular modulation scheme for underwater communication. Differently for…

Audio signalSettore ING-INF/03 - TelecomunicazioniComputer scienceAcousticsTransmitterambiguity function Doppler JANUS Underwater Watermarksymbols.namesakeTransmission (telecommunications)ModulationDistortionModulation (music)symbolsDoppler effectUnderwater acoustic communicationCommunication channelGLOBECOM 2020 - 2020 IEEE Global Communications Conference
researchProduct

LASCA and PPG imaging for non-contact assessment of skin blood supply

2013

Laser speckle contrast analysis (LASCA) offers a non-contact, full-field, and real-time mapping of capillary blood flow and can be considered as an alternative method to Laser Doppler perfusion imaging (LDPI). Photoplethysmography (PPG) is well known technique for assessment of skin blood pulsations that can be related to blood flow. In recent years several studies have been done on development of non-contact PPG imaging (PPGI). LASCA and PPGI techniques are simpler and cheaper compared with LDPI. LASCA technique has been implemented in several commercial instruments. However, these systems are still too expensive and bulky to be widely available. Several optical techniques have found new i…

CMOS sensorPixelComputer scienceSkin blood flowbusiness.industryColor imageBlood flowArterial occlusionsymbols.namesakeSpeckle patternOpticsPhotoplethysmogramsymbolsBlood supplybusinessDoppler effectBiomedical engineeringMedical Imaging 2013: Physics of Medical Imaging
researchProduct

The automated assesment of artery hemodynamic parameters from ultrasound video

2012

The custom designed video processing software for analysis of B-mode and Doppler-mode ultrasound video has been proposed in this work. The software allows adjusting user-defined thresholds and tolerance levels to enhance contour detection in noisy and artifacted ultrasound images. The developed software is able to evaluate 16 hemodynamic parameters (artery diameter, pulse rate and flow velocity related parameters) in each cardiac cycle. The measurements were performed intermittently recording artery diameter (B-mode) and flow velocity (Doppler-mode). Software has validated in femoral artery measurements. The hemodynamic parameters computed by software were consistent with those obtained by …

Cardiac cyclebusiness.industryComputer scienceUltrasoundVideo processingFemoral arterysymbols.namesakeSoftwareFlow velocitymedicine.arterySonographersymbolsmedicinebusinessDoppler effectBiomedical engineeringThe 4th 2011 Biomedical Engineering International Conference
researchProduct

Comparison between doppler-echocardiography and uncalibrated pulse contour method for cardiac output measurement. a multicenter observational study

2016

Objectives: Echocardiography and pulse contour methods allow, respectively, noninvasive and less invasive cardiac output estimation. The aim of the present study was to compare Doppler echocardiography with the pulse contour method MostCare for cardiac output estimation in a large and nonselected critically ill population. Design: A prospective multicenter observational comparison study. Setting: The study was conducted in 15 European medicosurgical ICUs. Patients: We assessed cardiac output in 400 patients in whom an echocardiographic evaluation was performed as a routine need or for cardiocirculatory assessment. Interventions: None. Measurements and Main Results: One echocardiographic car…

Cardiac outputgenetic structuresintensive care unitsBlood PressureDoppler echocardiographyCritical Care and Intensive Care Medicinearterial waveform analysis; cardiac output; Doppler echocardiography; echocardiography; hemodynamic monitoring; pulse contour method; Critical Care and Intensive Care Medicinehemodynamic monitoring0302 clinical medicine030202 anesthesiologyechocardiographyhumansarterial waveform analysisarterial waveform analysis; cardiac output; doppler echocardiography; echocardiography; hemodynamic monitoring; pulse contour method; heart; humans; intensive care units; linear models; monitoring; physiologic; prospective studies; blood pressure; cardiac output; echocardiography; doppler; pulse; critical care and intensive care medicinemedicine.diagnostic_testPulse (signal processing)physiologicblood pressureHeartEchocardiography Dopplercardiovascular systemCardiologysymbolsLinear ModelDoppler effectHumandoppler echocardiographymedicine.medical_specialtyIntensive Care UnitLess invasiveheartpulse contour methoddoppler03 medical and health sciencesCardiac output measurementsymbols.namesakeInternal medicinemedicinePulsearterial waveform analysiMonitoring Physiologicbusiness.industrycardiac output030208 emergency & critical care medicineDoppler echocardiographyprospective studiesProspective StudiemonitoringMulticenter studycritical care and intensive care medicineObservational studylinear modelsbusinesspulse
researchProduct

On the spectral moments of non-WSSUS mobile-to mobile double-Rayleigh fading channels

2017

This paper deals with the mathematical analysis of the spectral moments of non-wide-sensestationary uncorrelated-scattering (non-WSSUS) mobile-to-mobile (M2M) double-Rayleigh fading channels. The point of departure is a recently proposed geometry-based statistical model (GBSM) for M2M double-Rayleigh fading channels from which general analytical expressions are derived for the average Doppler shift, Doppler spread, average delay, and delay spread. Closed-form solutions of such expressions are presented for the particular case of the geometrical two-rings scattering model. The obtained results indicate that the average Doppler shift and Doppler spread are directly influenced by not only the …

Carrier signalComputer scienceScatteringBandwidth (signal processing)020206 networking & telecommunications020302 automobile design & engineering02 engineering and technologyCommunications systemDelay spreadsymbols.namesake0203 mechanical engineeringComputer Science::Networking and Internet Architecture0202 electrical engineering electronic engineering information engineeringsymbolsFadingStatistical physicsDoppler effectComputer Science::Information TheoryRayleigh fadingCommunication channel2017 IEEE 28th Annual International Symposium on Personal, Indoor, and Mobile Radio Communications (PIMRC)
researchProduct

A Trajectory-Driven 3D Channel Model for Human Activity Recognition

2021

This paper concerns the design, analysis, and simulation of a 3D non-stationary channel model fed with inertial measurement unit (IMU) data. The work in this paper provides a framework for simulating the micro-Doppler signatures of indoor channels for human activity recognition by using radiofrequency-based sensing technologies. The major human body segments, such as wrists, ankles, torso, and head, are modelled as a cluster of moving point scatterers. We provide expressions for the time variant (TV) speed and TV angles of motion based on 3D trajectories of the moving person. Moreover, we present mathematical expressions for the TV Doppler shifts and TV path gains associated with each movin…

Channel transfer functionGeneral Computer ScienceComputer scienceInternet of ThingsComputació centrada en humansDoppler EfecteActivity recognitionsymbols.namesakespectrogramInertial measurement unitVDP::Teknologi: 500::Medisinsk teknologi: 620Channel measurementsnon-stationary fading channelsmedicineGeneral Materials ScienceComputer visionNon-stationary fading channelsReconeixement de formes (Informàtica)channel state informationSpectrogrambusiness.industryWireless sensingGeneral Engineering:Enginyeria de la telecomunicació::Processament del senyal::Reconeixement de formes [Àrees temàtiques de la UPC]TorsoInertial measurement unitsExpression (mathematics)TK1-9971Time-variant Doppler power characteristicsmedicine.anatomical_structureChannel state informationHuman-centered computingchannel transfer functiontime-variant Doppler power characteristicsTrajectorysymbolsChannel state informationSpectrogramMicro-Doppler signature:Informàtica::Intel·ligència artificial [Àrees temàtiques de la UPC]Electrical engineering. Electronics. Nuclear engineeringArtificial intelligenceHuman activity recognitionbusinessDoppler effect
researchProduct

High-resolution photoacoustic Raman spectroscopy of gases

1992

A high-resolution photoacoustic Raman spectroscopy experiment is described. The resolution achieved by using two single-mode pulsed lasers is about 0.0054 cm −1 (full width at half maximum intensity). The experiment was tested first on the v 1 /2v 2 bands of CO 2 and gave an increase of at least about one order of magnitude in the signal-to-noise ratio with respect to stimulated Raman spectroscopy at low pressure (ca. 10 Torr ≃ 1.3 kPa). The sensitivity is also demonstrated by the study of the weak hot band v 1 +v 2 −v 2 of CO 2 . In both cases, the experimental line shape is well reproduced by taking into account Doppler and collisional effects. A comparison with CARS spectra was also made

ChemistryResolution (electron density)Analytical chemistryLaserHot bandSpectral linelaw.inventionsymbols.namesakeFull width at half maximumlawsymbolsGeneral Materials ScienceRaman spectroscopySpectroscopyDoppler effectSpectroscopyJournal of Raman Spectroscopy
researchProduct