Search results for "dosage"
showing 10 items of 516 documents
Hippocampal dose during Linac-based stereotactic radiotherapy for brain metastases: An observational study
2017
Abstract Introduction Aim of the present study is to evaluate homolateral and contralateral hippocampus (H-H, C-H, respectively) dose during Fractionated Stereotactic Radiotherapy (FSRT) or Radiosurgery (SRS) for brain metastases (BM). Materials & methods Patients with BM 3 months, were considered for SRS/FSRT (total dose 15–30 Gy, 1–5 fractions). For each BM, a Flattening Filter Free (FFF) Volumetric Modulated Arc Therapy (VMAT) plan was generated with one or two arcs. Hippocampi were not considered during optimizations phase and were contoured and evaluated retrospectively in terms of dose: the Dmedian, Dmean, D0.1cc and the V1Gy, V2Gy, V5Gy and V10Gy were analyzed. Results From April 2…
Deletion of Chromosome 11q Predicts Response to Anthracycline-Based Chemotherapy in Early Breast Cancer
2007
Abstract Despite the recent consensus on the eligibility of adjuvant systemic therapy in patients with lymph node–negative breast cancer (NNBC) based on clinicopathologic criteria, specific biological markers are needed to predict sensitivity to the different available therapeutic options. We examined the feasibility of developing a genomic predictor of chemotherapy response and recurrence risk in 185 patients with NNBC using assembled arrays containing 2,460 bacterial artificial chromosome clones for scanning the genome for DNA copy number changes. After surgery, 90 patients received anthracycline-based chemotherapy, whereas 95 did not. Tamoxifen was administered to patients with hormone r…
Use of long acting injectable aripiprazole before and through pregnancy in bipolar disorder: a case report
2019
Abstract Background Long-acting injectable (LAI) antipsychotics for psychotic disorders provide advantages in treatment compliance, but data on their use in pregnancy are very limited. We present a clinical case of aripiprazole LAI use in pregnancy. Case presentation A 43-year-old woman diagnosed with bipolar disorder, with several relapses due to treatment interruption while trying to conceive. Finally, aripiprazole LAI treatment was planned by mutual agreement between doctor and the patient, who took aripiprazole LAI before and during pregnancy. She gave birth at 40 weeks to a 3500 g baby girl with no congenital malformations, who was healthy at 5 months after delivery. Conclusion As far …
In Vitro Percutaneous Penetration of Acyclovir from Solvent Systems and Carbopol 971-P Hydrogels: Influence of Propylene Glycol
2005
The mechanism underlying propylene glycol (PG) effects on acyclovir (ACV) penetration through human epidermis were studied. Solvent systems and Carbopol gels containing increasing percentage of PG (from 0% to 70%, w/w) were used. Viscosity studies of both vehicles were carried out to characterise the influence of rheological behaviour. In solvent systems skin permeation values of ACV increase as the concentration of PG increase yielding a maximum enhancement ratio (ER = 10) for 70% PG. The release rate of ACV from gels was determined. Higuchi's model was used to estimate the apparent diffusion coefficient of the drug. These values show a decrease as the content of PG in the vehicle increase…
The combined operative and radiotherapeutic treatment (CORT) of recurrent tumors infiltrating the pelvic wall: First experience with 18 patients
1992
CORT is a new radiosurgical treatment concept for patients with recurrent gynecologic malignancies infiltrating the pelvic wall. The operative part consists of (i) staging laparotomy; (ii) maximum debulking of the tumor from the pelvic wall and exenteration of infiltrated central pelvic organs; (iii) implantation of brachytherapy guiding tubes on the residual tumor/tumor bed at the pelvic wall; (iv) pelvic wall plasty with muscle and omentum flaps to create a protective distance between the tubes and the pelvic hollow organs and to induce therapeutic angiogenesis; and (v) surgical reconstruction of bowel, bladder, and vulvoperineovaginal functions. Radiation is given postoperatively as frac…
CT exposure in adult and paediatric patients: a review of the mechanisms of damage, relative dose and consequent possible risks.
2014
An increase has been observed not only in the absolute number of CT examinations but also in the length of coverage and number of scanning phases, with the result that exposure to ionising radiation from CT is becoming an increasingly serious problem. The extent of the problem is not entirely known and cannot be adequately addressed without proper knowledge of all the phases that leads to the effective dose calculation. In light of the growing awareness of the issue of ionising radiation dose and the possible risk for the individual and the population, there is a need for radiologists, medical physicists and radiographers to play an active role in dose management. In this review, the author…
Endovascular Embolization of a Large High-Flow Splenic Arteriovenous Fistula and Aneurysm Using the Amplatzer Vascular Plug II.
2015
We describe the use of an Amplatzer Vascular Plug (AVP) II for embolizing a large high-flow splenic arteriovenous fistula and an aneurysm in a young patient. This patient presented to our center with persistent mild abdominal discomfort, 5 years after open splenectomy. Contrast-enhanced computed tomography angiography showed the presence of a fistula between the splenic arterial and splenic venous remnants and a resultant fusiform aneurysmal dilatation of the residual splenic vein. We decide to embolize the splenic artery with a 12-mm diameter AVP II with an oversizing by 70% of the vessel diameter. Celiac angiography performed 5 min postembolization revealed complete obliteration of the sp…
Fetal dose measurements and shielding efficiency assessment in a custom setup of (192)Ir brachytherapy for a pregnant woman with breast cancer.
2015
To assess the radiation dose to the fetus of a pregnant patient undergoing high-dose-rate (HDR) (192)Ir interstitial breast brachytherapy, and to design a new patient setup and lead shielding technique that minimizes the fetal dose.Radiochromic films were placed between the slices of an anthropomorphic phantom modeling the patient. The pregnant woman was seated in a chair with the breast over a table and inside a leaded box. Dose variation as a function of distance from the implant volume as well as dose homogeneity within a representative slice of the fetal position was evaluated without and with shielding.With shielding, the peripheral dose after a complete treatment ranged from 50 cGy at…
Managing Adult-onset Still's disease: The effectiveness of high-dosage of corticosteroids as first-line treatment in inducing the clinical remission.…
2019
Abstract To assess the effectiveness of the treatment with high dosage of corticosteroids (CCSs), as first-line therapy, in inducing remission in naïve Adult-onset Still's disease (AOSD) patients compared with low dosage of CCSs, after 6 months. To further evaluate the rate of patients maintaining the remission and the rate of CCSs discontinuation, after additional 12 months of follow-up. A retrospective evaluation of patients prospectively followed was designed to compare the rate of clinical remission in naïve AOSD patients treated with high dosages of CCSs (0.8–1 mg/kg/day of prednisone-equivalent) or low dosage of CCSs (0.2–0.3 mg/kg/day of prednisone-equivalent), after 6 months. An add…
Abdominal Computed Tomography Angiography at 80kV: feasibility study.
2014
preliminary evaluation of different dose reduction algorithms in abdominal Computed Tomography Angiography (CTA) with standard scan protocols at 120kV vs. 80kV.prospective, randomized, crossover study. 60 consecutive patients who underwent CTA of the abdomen (Sensation 64, Siemens; Iomeprol 400 mgl/ml Bracco) for suspected or diagnosed Abdominal Aortic Aneurysm (AAA) were enrolled in the study. A standard 120kV/200mAs scan protocol was acquired in all patients (reference tube current modulated with Automatic Exposure Control). In each patient a second scan with 80kV/300mAs (Group 1; n. 20), 80kV/400mAs (Group 2; n. 20), 80kV/500mAs (Group 3; n. 20) was acquired. We used the same scan/recons…