Search results for "dynamometer"
showing 10 items of 53 documents
Analog isolated electronic dynamometer based on a magnetoresistive current sensor.
2017
In this work, an electronic system is presented to measure the force applied by a solenoid. The originality of the work is focused on the use of a magnetoresistive current sensor to provide the isolation barrier needed in the actual industrial plant where the solenoids are working. The design of the electronic system is presented as well as experimental measurements as a result of a calibration process showing a negligible hysteresis with that specific sensor. The magnetoresistive current sensor is used to develop transmission functions rather than playing its usual sensing roles.
Association between muscular strength and cognition in people with major depression or bipolar disorder and healthy controls
2018
Importance Objective physical fitness measures, such as handgrip strength, are associated with physical, mental, and cognitive outcomes in the general population. Although people with mental illness experience reduced physical fitness and cognitive impairment, the association between muscular strength and cognition has not been examined to date. Objective To determine associations between maximal handgrip strength and cognitive performance in people with major depression or bipolar disorder and in healthy controls. Design, Setting, and Participants In a multicenter, population-based study conducted between February 13, 2005, and October 1, 2010, in the United Kingdom, cross-sectional analys…
Long-Term Determinants of Muscle Strength Decline: Prospective Evidence from the 22-Year Mini-Finland Follow-Up Survey
2012
Objectives: To examine long-term changes in handgrip strength and the factors predicting handgrip strength decline. Design: Longitudinal cohort study with 22 years of follow-up. Setting: Population-based Mini-Finland Health Examination Survey in Finland. Participants: Nine hundred sixty-three men and women aged 30 to 73 at baseline. Measurements: Handgrip strength was measured using a handheld dynamometer at baseline and follow-up. Information on potential risk factors, namely lifestyle and chronic conditions, and their changes throughout the follow-up were based on health interviews. Results: Based on linear mixed-effect models, midlife physically strenuous work, excess body weight, smokin…
Effect of chronic unloading and rehabilitation on human Achilles tendon properties: a velocity-encoded phase-contrast MRI study
2008
The objective of this study was to measure and monitor changes in Achilles tendon mechanical properties and force production capability of triceps surae muscles after 4 wk of limb suspension and 6 wk of physical rehabilitation. Five healthy volunteers underwent unilateral lower limb suspension followed by weekly physiotherapy. A velocity-encoded, phase-contrast magnetic resonance imaging (VE-PC-MRI) technique was used to estimate the tendon strain as a function of force produced during the submaximal isometric contractions. After limb suspension, triceps surae muscle strength decreased to 53.2 ± 15.6% (mean ± SD) of the presuspension level ( P < 0.05). Young's modulus, estimated from the…
Cardiorespiratory and Neuromuscular Responses to Motocross Riding
2008
The aim of the present study was to examine physiological and neuromuscular responses during motocross riding at individual maximal speed together with the riding-induced changes in maximal isometric force production. Seven A-level (group A) and 5 hobby-class (group H) motocross-riders performed a 30-minute riding test on a motocross track and maximal muscle strength and oxygen uptake (VO2max) tests in a laboratory. During the riding the mean (+/-SD) VO2 reduced in group A from 86 +/- 10% to 69 +/- 6% of the maximum (P < 0.001), whereas in group H the corresponding reduction was from 94 +/- 25% to 82 +/- 20% (P < 0.05). This relative VO2 during the riding correlated with riding speed (r = 0…
Do Stretch Durations Affect Muscle Mechanical and Neurophysiological Properties?
2016
International audience; The aim of the study was to determine whether stretching durations influence acute changes of mechanical and neurophysiological properties of plantar flexor muscles. Plantar flexors of 10 active males were stretched in passive conditions on an isokinetic dynamometer. Different durations of static stretching were tested in 5 randomly ordered experimental trials (1, 2, 3, 4 and 10×30-s). Fascicle stiffness index, evoked contractile properties and spinal excitability (Hmax/Mmax) were examined before (PRE), immediately after (POST0) and 5 min after (POST5) stretching. No stretch duration effect was recorded for any variable. Moreover, whatever the stretching duration, st…
Acute effects of dynamic stretching on mechanical properties result from both muscle-tendon stretching and muscle warm-up
2019
We investigated the acute effects of dynamic stretching on mechanical properties of plantar flexor muscles and tested the hypothesis that it would result from an interaction between muscle-tendon stretching and muscle warm-up. To test the stretching effect, dynamic stretching (DS) was compared to static stretching (SS). To test the warm-up effect, DS was compared to submaximal isometric muscle activity (SIMA) with similar contraction intensity. A control condition served as reference. These four conditioning activities were time matched (2×20s) and tested on separate days on 13 volunteers. Electrical neurostimulation was applied to investigate muscle mechanical properties (peak doublet torq…
Effects of ageing on motor unit activation patterns and reflex sensitivity in dynamic movements.
2009
Both contraction type and ageing may cause changes in H-reflex excitability. H reflex is partly affected by presynaptic inhibition that may also be an important factor in the control of MU activation. The purpose of the study was to examine age related changes in H-reflex excitability and motor unit activation patterns in dynamic and in isometric contractions. Ten younger (YOUNG) and 13 elderly (OLD) males performed isometric (ISO), concentric (CON) and eccentric (ECC) plantarflexions with submaximal activation levels (20% and 40% of maximal soleus surface EMG). Intramuscular EMG data was analyzed utilizing an intramuscular spike amplitude frequency histogram method. Average H/M ratio was a…
Reliability of knee extension and flexion measurements using the Con-Trex isokinetic dynamometer.
2007
The aim of this study was to evaluate the reliability of isokinetic and isometric assessments of the knee extensor and the flexor muscle function using the Con-Trex isokinetic dynamometer. Thirty healthy subjects (15 males, 15 females) were tested and retested 7 days later for maximal strength (isokinetic peak torque, work, power and angle of peak torque as well as isometric maximal voluntary contraction torque and rate of torque development) and fatigue (per cent loss and linear slope of torque and work across a series of 20 contractions). For both the knee extensor and the flexor muscle groups, all strength data - except angle of peak torque - demonstrated moderate-to-high reliability, wi…
Diurnal Rhythm of the Muscular Performance of Elbow Flexors During Isometric Contractions
1996
The influence of time of day on elbow flexion torque was studied. Thirteen physical education students, 7 males and 6 females, made maximal and submaximal isometric contractions at 90 degrees of elbow flexors using a dynamometer. The torque developed was measured on each contraction. The myoelectric activity of the biceps muscle was also measured at the same time by surface electromyography (EMG) and quantified from the root mean square (RMS) activity. Torque and surface EMGs were measured at 6:00, 9:00, 12:00, 15:00, 18:00, 21:00, and 24:00 h over the same day. Oral temperature before each test session was measured on each occasion after a 30-min rest period. We observed a diurnal rhythm i…