Search results for "dynamometer"

showing 10 items of 53 documents

Inter- and intrarater reliability of two proprioception tests using clinical applicable measurement tools in subjects with and without knee osteoarth…

2017

Abstract Background The therapeutic value of proprioceptive-based exercises in knee osteoarthritis (KOA) management warrants investigation of proprioceptive testing methods easily accessible in clinical practice. Objective To estimate inter- and intrarater reliability of the knee joint position sense (KJPS) test and knee force sense (KFS) test in subjects with and without KOA. Design Cross-sectional test-retest design. Method Two blinded raters performed independently repeated measures of the KJPS and KFS test, using an analogue inclinometer and handheld dynamometer, respectively, in eight KOA patients (12 symptomatic knees) and 26 healthy controls (52 asymptomatic knees). Intraclass correl…

AdultMalemedicine.medical_specialtyRange of Motion Articular/physiologyIntraclass correlationPhysical Therapy Sports Therapy and RehabilitationOsteoarthritisMuscle Strength DynamometerKnee Joint03 medical and health sciencesDisability Evaluation0302 clinical medicinePhysical medicine and rehabilitationReference ValuesmedicineHumans030212 general & internal medicineRange of Motion ArticularReliability (statistics)Aged030203 arthritis & rheumatologyObserver VariationOsteoarthritis Knee/diagnosisbusiness.industryRepeated measures designIntra-rater reliabilityMiddle AgedOsteoarthritis Kneemedicine.diseaseProprioceptionKnee painStandard errorCross-Sectional StudiesPhysical therapyFemaleHuman medicinemedicine.symptombusinessProprioception/physiologyMusculoskeletal sciencepractice
researchProduct

Age-related differences in Achilles tendon properties and triceps surae muscle architecture in vivo

2012

This study examined the concurrent age-related differences in muscle and tendon structure and properties. Achilles tendon morphology and mechanical properties and triceps surae muscle architecture were measured from 100 subjects [33 young (24 ± 2 yr) and 67 old (75 ± 3 yr)]. Motion analysis-assisted ultrasonography was used to determine tendon stiffness, Young's modulus, and hysteresis during isometric ramp contractions. Ultrasonography was used to measure muscle architectural features and size and tendon cross-sectional area. Older participants had 17% lower ( P < 0.01) Achilles tendon stiffness and 32% lower ( P < 0.001) Young's modulus than young participants. Tendon cross-section…

AdultMalemusculoskeletal diseasesAgingMuscle Strength DynamometerPhysiologyVideo RecordingMuscle Strength DynamometerAchilles TendonYoung Adult03 medical and health sciences0302 clinical medicineTriceps surae muscleIn vivoElastic ModulusPhysiology (medical)Age relatedActivities of Daily LivingHumansMedicineMuscle StrengthMuscle SkeletalAgedUltrasonographyAchilles tendonbusiness.industryAge FactorsBiomechanics030229 sport sciencesAnatomymusculoskeletal systemAdaptation PhysiologicalBiomechanical Phenomenamedicine.anatomical_structureFemalemedicine.symptombusinessMuscle architectureLocomotion030217 neurology & neurosurgeryMuscle ContractionMuscle contractionJournal of Applied Physiology
researchProduct

Neuromuscular Responses to 14 Weeks of Traditional and Daily Undulating Resistance Training

2015

This study compared traditional (TP) and daily undulating (DUP) periodization on muscle strength, EMG-estimated neural drive and muscle architecture of the quadriceps femoris (QF). 10 non-athletic females (24.4±3.2 years) performed 14 weeks of isometric training for the QF exercising 1 leg using TP and the contralateral leg using DUP. Intensities varied from 60% to 80% of MVC and the intensity zones and training volume were equated for each leg. Knee extension MVC, maximal voluntary QF-EMG activity and vastus lateralis (VL) muscle architecture were measured in both legs before, after 6 weeks and after 14 weeks of training using dynamometry, surface EMG and ultrasonography. Isometric MVC and…

AdultMuscle Strength DynamometerKnee JointPhysical Therapy Sports Therapy and RehabilitationMuscle Strength DynamometerElectromyographyIsometric exerciseKnee extensionQuadriceps MuscleYoung AdultIsometric ContractionmedicineHumansOrthopedics and Sports MedicineMuscle Strengthmedicine.diagnostic_testElectromyographybusiness.industryResistance trainingResistance TrainingAnatomymusculoskeletal systembody regionsAnesthesiadupFemaleUltrasonographybusinessMuscle architectureInternational Journal of Sports Medicine
researchProduct

Assessment of maximal handgrip strength: How many attempts are needed?

2017

BACKGROUND: Handgrip strength (HGS) is used to identify individuals with low muscle strength (dynapenia). The influence of the number of attempts on maximal HGS is not yet known and may differ depending on age and health status. This study aimed to assess how many attempts of HGS are required to obtain maximal HGS.METHODS: Three cohorts (939 individuals) differing in age and health status were included. HGS was assessed three times and explored as continuous and dichotomous variable. Paired t-test, intraclass correlation coefficients (ICC) and Bland-Altman analysis were used to test reproducibility of HGS. The number of individuals with misclassified dynapenia at attempts 1 and 2 with respe…

AdultSarcopeniaAdolescentsex differenceHealth Statusadult; aged; aging; Article; cohort analysis; dual energy X ray absorptiometry; dynamometer; female; four minute walk test; geriatric assessment; grip strength; health status; human; major clinical study; male; middle aged; muscle strength; outpatient; priority journal; reproducibility; sarcopenia; sex difference; six minute walk test; walk test; walking speed; X ray bone densitometer; Aged; Geriatric assessment; Muscle strength; Reproducibility of Results; Sarcopeniahealth statuswalking speedArticlesarcopeniaCohort StudiesYoung Adultmalesix minute walk testmiddle aged80 and overHumansfour minute walk testhumanMuscle StrengthreproducibilityGeriatric AssessmentX ray bone densitometerAgedAged 80 and overdual energy X ray absorptiometryHand StrengthMuscle strengthadultwalk testagingAge FactorsReproducibility of ResultsOriginal ArticlesdynamometerMiddle Agedcohort analysismajor clinical studyGeriatric assessmentfemaleCross-Sectional Studiespriority journalgrip strengthoutpatientOriginal Articlelihasvoima
researchProduct

Thresholds of handgrip strength for all-cause, cancer, and cardiovascular mortality: A systematic review with dose-response meta-analysis.

2022

Background While handgrip strength is associated with all-cause and cause-specific mortality, whether such associations are dose-dependent is largely unknown. Therefore, we conducted a systematic review on the dose-response relationship of handgrip strength with all-cause mortality, cancer, and cardiovascular mortality. Methods The data source included three electronic databases (PubMed/MEDLINE, Web of Science and Scopus) from inception to 8 February 2022. Prospective cohort studies of healthy adults with objective measures of handgrip strength were included. Two researchers independently screened studies, extracted data, and assessed risk of bias. We used estimates regarding handgrip stren…

Aged 80 and overMalePublic healthAgingHand StrengthLongevityBiochemistrySalut públicaCardiovascular SystemRisk factorsNeurologyCardiovascular DiseasesNeoplasmsHumansAvaluació del riscFemaleProspective StudiesMuscle strength dynamometerMolecular BiologyBiotechnologyAgedAgeing research reviews
researchProduct

Effects of strength and endurance training on isometric muscle strength and walking speed in elderly women

1996

The separate effects of 18 weeks of intensive strength and endurance training on isometric knee extension (KE) and flexion (KF) strength and walking speed were studied in 76- to 78- year-old women. Maximal voluntary isometric force for both KE and KF was measured in a sitting position on a custom-made dynamometer chair at a knee angle of 60 degrees from full extension. Maximal walking speed was measured over a distance of 10 m. The endurance-trained women increased KE torque and KE torque/body mass after the first 9 weeks of training when compared with the controls. when comparing the baseline, 9 week and 18 week measurements within the groups separately, both the endurance- and strength-tr…

Agingmedicine.medical_specialtyTime FactorsDynamometerPhysiologyStrength trainingbusiness.industryeducationWalkingIsometric exerciseSittingPreferred walking speedEndurance trainingIsometric ContractionMuscle strengthPhysical therapymedicineHumansFemaleKneeExercise physiologybusinessExerciseAgedActa Physiologica Scandinavica
researchProduct

Determination of hydrodynamic drag forces and drag coefficients on human leg/foot model during knee exercise.

2000

Objective. The purpose of this laboratory experiment was to measure hydrodynamic drag forces in barefoot/hydro-boot conditions and accordingly, to determine the coefficients of drag on human leg/foot model during simulated knee extension–flexion exercise. Design. The prosthesis of the human lower leg was set in a water tank and connected into an isokinetic force dynamometer to measure resistive forces during knee motion. Background. Quantifying resistance for aquatic exercises has been a challenge in hydrotherapy. The use of models of foot/leg provides a practical method to calculate coefficients of drag and to estimate resistance for rehabilitation purposes in musculoskeletal and amputee p…

Drag coefficientanimal structuresKnee JointBiophysicsIn Vitro TechniquesBarefootPhysical PhenomenaHumansOrthopedics and Sports MedicineHuman legMathematicsHydrotherapyDynamometerWater resistanceFootPhysicstechnology industry and agricultureWaterMechanicsBiomechanical PhenomenaExercise Therapybody regionsLift (force)Models StructuralClassical mechanicsDragbiological sciencesStress MechanicalRange of motionhuman activitiesClinical biomechanics (Bristol, Avon)
researchProduct

Validity and reliability of the DiCI for the measurement of shoulder flexion and abduction strength in asymptomatic and symptomatic subjects

2021

Background A higher risk of shoulder injury in the athletic and non-athletic population is frequently associated with strength deficits. Therefore, shoulder strength assessment can be clinically useful to identify and to quantify the magnitude of strength deficit. Thus, the aim of this study was to evaluate the validity and reliability of a DiCI (a new hand-held dynamometer) for the measurement of shoulder flexion and abduction strength in asymptomatic and symptomatic subjects. Methods Forty-three recreational athletes (29 males and 14 females; age: 22.1 ± 0.47 years; body mass: 68.7 ± 13.1 kg; height = 173.3 ± 9.7 cm) and 40 symptomatic subjects (28 males and 12 females; age: 49.9 ± 8.1 y…

Drugs and DevicesRelative reliabilitymedicine.medical_specialtyShoulderAnatomy and PhysiologyPopulationValidity/reliabilityValiditySymptomaticShoulder flexionAsymptomaticGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciences0302 clinical medicineRheumatologymedicineeducationShoulder injury030222 orthopedicseducation.field_of_studybiologyAthletesbusiness.industryGeneral NeuroscienceR030229 sport sciencesGeneral MedicineKinesiologybiology.organism_classificationHand-held dynamometerOrthopedicsStandard errorPhysical therapyMedicinemedicine.symptomGeneral Agricultural and Biological SciencesbusinessPeerJ
researchProduct

Quality evaluation of grapes for mechanical harvest using vis NIR spectroscopy

2019

Mechanical harvest of grapes is one of the operations that mostly influence the quality of the future wine. The shaking frequency of the harvesting machine is usually adjusted on the basis of the grape berry characteristics in order to limit grape juice production that is a potential cause of uncontrolled fermentations. These evaluations usually require time, personnel and laboratory analyses. The introduction of a vis NIR system to rapidly and reliably evaluate the berry properties in field before mechanical harvest could be a good alternative. The aim of this study was to evaluate the feasibility of applying vis NIR spectroscopy as a non-destructive technique on grapes cv. Syrah and Chard…

DynamometerOrdinary least square (OLS)Non-destructive analysiSettore AGR/09 - Meccanica AgrariaDetachment force
researchProduct

STUDY ON THE TUNNEL PASTEURIZER ON TABLE OLIVES PROCESSING

2015

The application of heat treatment is particularly important in maintaining the organoleptic characteristics of fermented agro-food products, which potential consumers perceive as reflecting the quality of these foodstuffs. However, heat treatments can be cause of deterioration of many quality parameters of agro-food products, including texture, intended as the consistency of the pulp. In this study 'Nocellara del Belice' table olives produced in 2010 and packaged in glass jars were subjected to pasteurization at industrial scale using a tunnel pasteurizer with a core temperature of 75°C for 8 min. The aim of the study was to mechanically evaluate the pulp texture evolution that contributes …

DynamometerTable oliveTunnel pasteurizerSettore AGR/09 - Meccanica AgrariaTable (landform)HorticultureFlesh firmneMathematicsMarine engineeringActa Horticulturae
researchProduct