Search results for "dynamometry"

showing 2 items of 2 documents

The Total Work Measured During a High Intensity Isokinetic Fatigue Test Is Associated With Anaerobic Work Capacity.

2016

The purpose of the study was to determine whether total work measured during a high intensity isokinetic fatigue test (TWFAT) could be considered as a valid measure of anaerobic work capacity (AWC), such as determined by total work measured during a Wingate Anaerobic Test (TWWAnT). Twenty well-trained cyclists performed 2 randomly ordered sessions involving a high intensity isokinetic fatigue test consisting in 30 reciprocal maximal concentric contractions of knee flexors and extensors at 180°·s(-1), and a Wingate Anaerobic Test. We found that TWFAT of knee extensors was largely lower than TWWAnT (4151 ± 691 vs 22313 ± 2901 J, respectively, p0.05, Hedge's g = 4.27). Both measures were highl…

[ SDV.NEU ] Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]Wingate anaerobic test[SDV.NEU]Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]muscle fatigue[SDV.NEU] Life Sciences [q-bio]/Neurons and Cognition [q-bio.NC]cyclistsphysiological assessmenmusculoskeletal systemIsokinetic dynamometryResearch ArticleJournal of sports sciencemedicine
researchProduct

Test−Retest Reliability of Isokinetic Ankle, Knee and Hip Strength in Physically Active Adults Using Biodex System 4 Pro

2023

Background: The isokinetic dynamometry is considered a gold standard in muscle strength testing. The reliability of lower limb isokinetic strength measurements has not been thoroughly evaluated. Objective: To examine the test−retest reliability of isokinetic ankle plantar and dorsiflexion, ankle inversion and eversion, knee extension and flexion and hip abduction and adduction strength in physically active adults using Biodex System 4 Pro. Methods: Peak torques (PTs) and average peak torques (APTs) of the dominant and nondominant lower limbs were tested twice in 19 physically active adults 7 to 14 days apart. Results: The intraclass correlation coefficients (ICC) values varied from excellen…

reliabilityisokinetic; dynamometry; Biodex; test−retest; reliability; ankle; knee; hiphippolvetkneeBiodex3121 Internal medicineBiochemistry Genetics and Molecular Biology (miscellaneous)dynamometrylonkka3142 Public health care science environmental and occupational healthtest−retestmittausmenetelmätnilkatmittauslaitteetStructural Biologyisokineettinen dynamometriankleisokineticBiotechnologyreliabiliteettilihasvoima
researchProduct