Characterization of estuarine sediments by near infrared diffuse reflectance spectroscopy
2008
It has been developed a partial least squares near infrared (PLS-NIR) method for the determination of estuarine sediment physicochemical parameters. The method was based on the chemometric treatment of first order derivative reflectance spectra obtained from samples previously lyophilized and sieved through a lower than 63 μm grid. Spectra were scanned from 833 to 2976 nm, averaging 36 scans per spectrum at a resolution of 8 cm-1, using chromatographic glass vials of 9.5 mm internal diameter as measurement cells. Models were built using reference data of 31 samples selected through the use of a hierarchical cluster analysis of NIR spectra of sediments obtained from the Ria de Arousa estuary…
Near-infrared emissive bacteriochlorin-diketopyrrolopyrrole triads: Synthesis and photophysical properties
2019
International audience; The synthesis of unprecedented energy transfer triads containing a near-infrared (NIR) emissive bacteriochlorin subunit and two diketopyrrolopyrrole (DPP) moieties linked to each other via ethynyl or zero-carbon spacers is presented. Their optical and fluorescence properties were determined in CHCl3 and toluene. These photophysical measurements highlight the ability of DPP scaffold to act as an effective energy donor, which once excited in the range 450-550 nm resulting nearly exclusively NIR emission of hydroporphyrin (ETE > 96%). Since DPP dyes are valuable structurally tunable fluorophores that may be used in the construction of high-performance multicomponent pho…
Use of reflectance infrared spectroscopy for monitoring the metal content of the estuarine sediments of the Nerbioi-Ibaizabal River (Metropolitan Bil…
2009
Multivariate partial least-squares (PLS) calibration models have been developed for the spatial and seasonal simultaneous monitoring of 14 trace elements (Al, As, Cd, Co, Cr, Cu, Fe, Mg, Mn, Ni, Pb, Sn, V, and Zn) in sediments from 117 samples taken in the estuary of the Nerbioi-Ibaizabal River. Models were based on the chemometric treatment of diffuse reflectance near-infrared (NIR) and attenuated total reflectance (ATR) mid infrared (MIR) spectra, obtained from samples previously lyophilized and sieved with a particle size lower than 63 microm. Vibrational spectra were scanned in both, NIR and MIR regions. Developed PLS models, based on the interaction between trace elements and organic m…
Combining near-infrared illuminants to optimize venous imaging
2007
The first and perhaps most important phase of a surgical procedure is the insertion of an intravenous (IV) catheter. Currently, this is performed manually by trained personnel. In some visions of future operating rooms, however, this process is to be replaced by an automated system. We previously presented work for localizing near-surface veins via near-infrared (NIR) imaging in combination with structured light ranging for surface mapping and robotic guidance. In this paper, we describe experiments to determine the best NIR wavelengths to optimize vein contrast for physiological differences such as skin tone and/or the presence of hair on the arm or wrist surface. For illumination, we empl…
Spectroscopic markers of the T-R quaternary transition in human hemoglobin
2004
n questo lavoro, usiamo un protocollo sol-gel per intrappolare e confrontare gli stati quaternari R e T di entrambi i deossigenati (deossiHb) ederivati di ossido di carbonio (HbCO) dell'emoglobina umana. La banda di assorbimento ottico del vicino infrarosso III e lo stretching di CO a infrarossibanda sono utilizzati per rilevare l'effetto della struttura quaternaria sulle proprietà spettrali di deoxyHb e HbCO; confronto con mioglobinaconsente una valutazione dei contributi terziari e quaternari ai turni di banda misurati. La RXLa transizione T è indicata per causare un bluspostamento della banda III di ~ 35 cm?1per deoxyHb e uno spostamento rosso della banda di allungamento CO di soli ~ 0…
Understanding and exploiting long-lived near-infrared emission of a molecular ruby
2018
Coordination chemistry reviews 359, 102 - 111 (2018). doi:10.1016/j.ccr.2018.01.004
Hyperspectral venous image quality assessment for optimum illumination range selection based on skin tone characteristics
2014
Background Subcutaneous veins localization is usually performed manually by medical staff to find suitable vein to insert catheter for medication delivery or blood sample function. The rule of thumb is to find large and straight enough vein for the medication to flow inside of the selected blood vessel without any obstruction. The problem of peripheral difficult venous access arises when patient’s veins are not visible due to any reason like dark skin tone, presence of hair, high body fat or dehydrated condition, etc. Methods To enhance the visibility of veins, near infrared imaging systems is used to assist medical staff in veins localization process. Optimum illumination is crucial to obt…
Central alterations of neuromuscular function and feedback from group III-IV muscle afferents following exhaustive high-intensity one-leg dynamic exe…
2015
The aims of this investigation were to describe the central alterations of neuromuscular function induced by exhaustive high-intensity one-leg dynamic exercise (OLDE, study 1) and to indirectly quantify feedback from group III-IV muscle afferents via muscle occlusion (MO, study 2) in healthy adult male humans. We hypothesized that these central alterations and their recovery are associated with changes in afferent feedback. Both studies consisted of two time-to-exhaustion tests at 85% peak power output. In study 1, voluntary activation level (VAL), M-wave, cervicomedullary motor evoked potential (CMEP), motor evoked potential (MEP), and MEP cortical silent period (CSP) of the knee extensor…
The effects of skin and core tissue cooling on oxygenation of the vastus lateralis muscle during walking and running
2016
Skin and core tissue cooling modulates skeletal muscle oxygenation at rest. Whether tissue cooling also influences the skeletal muscle deoxygenation response during exercise is unclear. We evaluated the effects of skin and core tissue cooling on skeletal muscle blood volume and deoxygenation during sustained walking and running. Eleven male participants walked or ran six times on a treadmill for 60 min in ambient temperatures of 22°C (Neutral), 0°C for skin cooling (Cold 1), and at 0°C following a core and skin cooling protocol (Cold 2). Difference between oxy/deoxygenated haemoglobin ([diffHb]: deoxygenation index) and total haemoglobin content ([tHb]: total blood volume) in the vastus lat…
Fabrication and characterization of tuned Gaussian mirrors for the visible and the near infrared
1988
A thin-film technique has been developed for vacuum fabrication of mirrors with Gaussian reflectivity profiles. Samples with diameters from 2 to 8 mm and assigned maximum reflectivities for visible or near-IR wavelengths have been made and their optical properties evaluated. By properly choosing both the geometry of the evaporation source and the masking system, one can obtain quasi-Gaussian or super-Gaussian reflectivity profiles.