Search results for "efficien"
showing 10 items of 3014 documents
USER- AND CONTEXT-ORIENTED CRITERIA FOR ASSESMENT OF HIGH EFFICIENCY POLYGENERATION PLANTS FOR BUILDINGS APPLICATIONS
2013
The eligibility criteria adopted to assess polygeneration plants as “highly efficient” can play a determinant role in favouring or discouraging the market growth of polygeneration systems, especially for buildings applications where economic viability is often more difficult to achieve. Basing on the current European framework, in this paper the opportunity to adopt user- and context-oriented criteria is discussed. After having identified three buildings with different uses (a large hotel, a hospital and an office building), the optimal layout and operation strategy of a polygeneration plant serving each building is determined; then, ex-post processing of economic and energetic results is u…
Fostering the energy efficiency through the energy savings: The case of the University of Palermo
2019
This paper reports the strategy implemented by the Palermo University (Italy) aimed at fostering the energy performance of its campus, particularly towards financing energy saving measures. The basic idea is that the money saved through the energy efficiency actions, constitute the main flywheel to fund further savings and energy efficiency interventions. Results of this paper might bring a useful contribution to the energy planning of cities, since campuses may be regarded as emblematic case study of what can be done in cities because they reproduce, at a little scale, the functioning of wider urban contexts.
Effect of the thermal storage dimensions on the performances of solar photovoltaic-thermal systems
2020
Abstract PV/T panels are innovative systems increasingly used in the building sector. As a matter of fact, in that context they allow a set of common problems to be addressed and often solved: lack of physical space and economic issues, always existing when PV and thermal panels are to be installed separately. Obviously, the main objective of PV/T panels is to enhance the electrical efficiency by cooling the PV cells, but the side positive effect is also the production of thermal energy, which can be suitably exploited with a proper configuration of the whole system and an appropriate design of its components. Their energy production and overall efficiency depend on several factors and ther…
Dynamic Lighting Strategies with Load Modulation Purposes to Reduce Peak Electrical Demand
2018
This paper proposes a study about the feasibility to modulate the indoor artificial lighting, taking into account both achievable energy savings and comfort conditions, in order to reduce lighting electric loads. In particular, it focuses on the possibility, on one hand, to decrease the luminous flux and, on the other hand, to change the Correlated Colour Temperature (CCT), in order to decrease the absorbed power. Moreover, the impact of daylight-linked control systems was considered. Finally, the possibility to combine the different technical solutions was analysed. The paper proposes the definition of daily scheduling referred to lighting energy management, in order to modulate the maximu…
Assessment of indoor illuminance and study on best photosensors' position for design and commissioning of Daylight Linked Control Systems. A new meth…
2018
Abstract Artificial lighting systems have to ensure appropriate illuminance with high energy efficiency according to best design practice and technical standards. These aims can be tackled, by incorporating a Daylight linked control system. However, the system behaviour is strongly influenced by several factors and, in particular, by the sensors' position. Indeed, very often the illuminance on work-plane is not fully correlated with illuminance measured by the photo-sensor used to control the luminaires. This fact leads to wrong information for the Daylight linked control systems affecting its efficacy. The artificial intelligence of Neural Networks can be exploited to provide a method for …
Assessing the lighting systems flexibility for reducing and managing the power peaks in smart grids
2020
Abstract The application of “shiftable” or “modulable” load (i.e. washing machine, dishwasher, etc.) in a Smart Grid, can provide energy saving or modify the power flows in the grid, allowing a reduction of the electrical power peak. This paper explores the possibility to modulate the indoor artificial lighting to support this reduction. The study examines the impact of two different measures of power shaving. On the one hand, the change of Correlated Colour Temperature of the light source, and, on the other hand, the dimming of its luminous flux. The possibility to merge the above-mentioned technical solutions is also analyzed. Based on these strategies, several daily schedules of lighting…
The impact of the software’s choice on dynamic daylight simulations’ results: A comparison between Daysim and 3ds Max Design®
2015
Abstract Evaluating indoor daylight availability is extremely important in order to define the characteristics of an environment in terms of visual comfort and energy performances of lighting systems. The criticism of the static calculation approach based on Daylight Factor led to the development of the Climate Based Daylight Modeling (CBDM) one. Dynamic simulations are performed thanks to the use of specific software and the choice of a calculation tool or another could provide different output results. Therefore the aim of this paper is to compare results of dynamic daylight simulations carried out with two different software, Daysim and 3ds Max Design® and referred to a simple office loc…
Strumenti incentivanti per l’efficienza energetica in edilizia.
2014
Efficientamento energetico di un distretto di edifici: uno studio di LCA semplificato
2022
Il presente lavoro si propone di individuare delle soluzioni di redesign per un piccolo gruppo di edifici con l’obiettivo di raggiungere il target di Positive Energy District e di valutare, attraverso la metodologia LCA, gli impatti ambientali incorporati nelle soluzioni proposte. I risultati ottenuti mostrano che il redesign induce una riduzione dei consumi energetici pari al 40,30% in fase d’uso rispetto agli edifici esistenti e si evidenziano miglioramenti significativi (fino al 56,03% per l’esaurimento delle risorse abiotiche, combustibili fossili) per la maggior parte degli indicatori ambientali. Pertanto, gli impatti connessi alla realizzazione degli interventi di redesign sono parzia…
The new building regulation plan schema in the town of Castelbuono (Sicily): the experience of FACTOR20- LIFE+ project
2014
The LIFE+ Programme is the European Union’s funding instrument for the environment. The general objective of LIFE+ is to contribute to the implementation, updating and development of EU environmental policy and legislation by co-financing pilot or demonstration projects with European added value. In the framework of LIFE+, the project “Forwarding demonstrative ACTions On a Regional and local scale (FACTOR20) to reach EU targets of the European Plan 20/20/20” was founded by European Commission. FACTOR20 is aimed to define a set of tools to support the planning of regional and national policies for the reduction of greenhouse gas emissions and for the reduction of energy consumption. The know…