Analyses of innovative glass blocks for BIPV: assessment of thermal and optical performance
2015
This paper illustrates the results of the performance analyses conducted on an innovative glass block integrated with thirdgeneration dye-sensitised solar cells (DSCs), designed to enable the construction of translucent and sustainable building envelopes. The analyses include the simulation of both thermal and optical performance with regard to different configurations of the photovoltaic (PV)-integrated glass block, and the results obtained are presented using two different programs: Comsol Multiphysics and WINDOW. The configurations may differ – for example, because of the position of the module inside the glass block, the type of DSC module used (composition, transparency, design) and th…
Mechanical Tests on Innovative BIPV Façade Components for Energy, Seismic, and Aesthetic Renovation of High-Rise Buildings
2018
The paper shows the results of mechanical tests carried out on prototypes of a new Building Integrated Photovoltaic (BIPV) component developed by the author and SBskin Smart Building Skin s.r.l. This patented innovative component is able to merge structural function, insulation proprieties, and production of clean energy for retrofit actions and/or the construction of translucent faç
The reflection coefficient of a flared microstrip line radiating in an infinite parallel-plate waveguide
1993
In this article the reflection coefficient of a tapered microstrip line radiating in an infinite parallel-plate conducting waveguide is calculated. The reflection coefficient at the feed line is evaluated by using the aperture admittance of the horn and the scattering matrix of the continuous taper. The theoretical behavior of the aperture admittance is shown and the reflection coefficient of a microstrip horn radiating in the parallel-plate region of a bootlace lens is measured in order to verify the model. © 1993 John Wiley & sons, Inc.
Intrusion Detection and Ejection Framework Against Lethal Attacks in UAV-Aided Networks: A Bayesian Game-Theoretic Methodology
2017
International audience; Advances in wireless communications and microelectronics have spearheaded the development of unmanned aerial vehicles (UAVs), which can be used to augment a ground network composed of sensors and/or vehicles in order to increase coverage, enhance the end-to-end delay, and improve data processing. While UAV-aided networks can potentially find applications in many areas, a number of issues, particularly security, have not been readily addressed. The intrusion detection system is the most commonly used technique to detect attackers. In this paper, we focus on addressing two main issues within the context of intrusion detection and attacker ejection in UAV-aided networks…
An overview of energy retrofit actions feasibility on Italian historical buildings
2017
Abstract Italian energy policy has determined important keystones in building energy efficiency regulations and their application throughout the country. However, there is still much work to be done in order to make sustainable societies and territories, especially in historical contexts that have the greatest potentiality of energy saving. In detail, in the framework of conservation, restoration, refurbishment, and retrofit actions, the debate among scientists, administrators and skilled people is still open due to the many aspects yet to be considered and solved. In this paper, the state of the art of Italian residential building heritage has been reviewed, while energy retrofit issues an…
Redesign of a Rural Building in a Heritage Site in Italy: Towards the Net Zero Energy Target
2017
In order to achieve the ambitious objective of decarbonising the economy, it is mandatory, especially in Europe and in Italy, to include the retrofitting of existing buildings. In a country where a large share of existing buildings have heritage value, it is important to design effective retrofit solutions also in historical buildings. In this context, the paper describes the experience of re-design of an existing rural building located in Sicily, inside the ancient Greeks' “Valley of the Temples”. An energy audit was performed on the building, and its energy uses were thoroughly investigated. A building model was developed in the TRNSYS environment and its performances validated. The valid…
Overview and future challenges of nearly zero energy buildings (nZEB) design in Southern Europe
2017
In times of great transition of the European construction sector to energy efficient and nearly zero energy buildings (nZEB), a market observation containing qualitative and quantitative indications should help to fill out some of the current gaps concerning the EU 2020 carbon targets. Next to the economic challenges, there are equally important factors that hinder renovating the existing residential building stock and adding newly constructed high performance buildings. Under these circumstances this paper summarises the findings of a cross-comparative study of the societal and technical barriers of nZEB implementation in 7 Southern European countries. The study analyses the present situat…
DE.DU.ENER.T. project: A prototype of a sustainable energy microsystem
2016
The paper presents a prototype of a microsystem for the integration and the optimal management of renewable energy sources in order to attain a reduction of the total energy consumption of a not residential building. The system composed by the building and the prototype is an energy sustainable microsystem and is located in Italy in the city of Valderice. The microsystem has been conceived in the ENPI (European Neighborhood and Partnership Instrument) cross-border cooperation Italy - Tunisia 2007-2013 DE.DU.ENER.T. (Le DEveloppement DUrable dans la production ENERgetique dans le Territoire) research project framework. In the paper the purposes of the DE.DU.ENER.T. project are presented and …
Energy-environmental and cost assessment of a set of strategies for retrofitting a public building toward nearly zero-energy building target
2017
Abstract The purpose of this study was to assess an energy retrofit of a building representative of those in public tertiary stock, to improve energy performance toward nearly Zero-Energy Building (nZEB) requirements. The building is located in the campus of the Politecnico di Milano University (Italy). Several hypothetical improvements regarding the building envelope and plants were assessed in terms of energy savings, costs, and the reduction of greenhouse gas emissions. The results of the study show that it is possible to reduce primary energy demand and associated emissions up to 40% from the current values by adopting market-available and well-proven technological solutions for retrofi…
Are the best available technologies the only viable for energy interventions in historical buildings?
2015
Worth aged buildings represent among the existing buildings a special case when it comes to their energy refurbishment. Unfortunately, the available technologies for building components characterized by high level of thermal performances show, not rarely, a limited compatibility with the architectural integrity of the building. In other words, the so-called Best Available Technologies, which are effectively adopted to optimize the building energy performances, in case of buildings to which a certain artistic, historic and/or architectural merit is recognized, i.e. heritage houses, might determine such kind of conflicts. This situation may lead to the selection of “non-invasive” but less per…