Search results for "elastomer"

showing 4 items of 134 documents

INTERACTIONS BETWEEN FUNCTIONALIZED THERMOPLASTIC ELASTOMER AND LAYERED DOUBLE HYDROXIDES

2016

Results coming from rheological analysis clearly suggest that in SEBS-g-MA-based nanocomposites, containing high amount of o-LDH, the formation of strong interactions between the dispersed nanoparticles and maleic functionalities of matrix occurs. A significant modification of the rheological behaviour can be noticed due to the formation of gel-like structures.

functionalized thermoplastic elastomer layered double hydroxides interactions nanocompositesthermoplastic elastomerinteractionslayered double hydroxides
researchProduct

Physicochemical Surface Properties of Various Intraocular Lenses

2001

<i>Purpose:</i> It is of major interest to understand how intraocular lens (IOL) surfaces interact with aqueous humor or tissues after implantation. Important parameters to describe the physicochemical surface properties are the contact angle and critical surface tension. Therefore, we performed measurements of the contact angle and critical surface tension of several commercially available IOLs. <i>Setting:</i> Department of Ophthalmology, Johannes Gutenberg University, Mainz, University Eye Hospital, Tübingen, and Max Planck Institute for Polymer Research, Mainz, Germany. <i>Methods:</i> A total of 17 commercially available standard quality IOL types (6…

genetic structuresBiocompatibilityPolymethyl methacrylatemedicine.medical_treatmentAcrylic ResinsAqueous humorIntraocular lensCellular and Molecular NeuroscienceOpticsCoated Materials BiocompatiblemedicinePolymethyl MethacrylateSurface TensionLenses IntraocularHeparinbusiness.industryChemistryGeneral MedicineBiocompatible materialeye diseasesSensory SystemsSilicone ElastomersOphthalmologyIntraocular lensesSilicone Elastomerssense organsbusinessBiomedical engineeringOphthalmic Research
researchProduct

Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes

2006

Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…

medicine.medical_specialtyRefractive errorgenetic structuresAnterior ChamberEye diseaseVisual AcuityIrisPhakic intraocular lensCorneaVision disorderLens Implantation IntraocularOphthalmologyLens CrystallineMyopiaHumansMedicineProspective StudiesIris clawDioptreLenses Intraocularbusiness.industryRefractive Errorsmedicine.diseaseeye diseasesSensory SystemsOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Silicone ElastomersSurgerysense organsmedicine.symptombusinessJournal of Cataract and Refractive Surgery
researchProduct

The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials

2008

The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with additionpolymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quaternary ammonium compounds (Sterigum Powder, SP) and glutaraldehyde plus an amino derivative (MD520, MD), respectively. The impressions were measured at 4 different time points: before any disinfection treatment (T0); after the first disinfection (T1); 6 hours after the first disinfection (T2); after th…

medicine.medical_specialtyTime FactorsMaterials scienceSurface PropertiesDisinfectantDentistryimpression materials disinfectants dimensional stability disinfection polyether addition-polymerized siliconeElastomerSilicone rubberchemistry.chemical_compoundSettore MED/28 - Malattie OdontostomatologicheImmersionMaterials TestingmedicineImmersion (virtual reality)HumansGeneral Dentistrybusiness.industryDental Impression MaterialsDental DisinfectantsAmmonium compoundsSurgeryImpressionDisinfectionQuaternary Ammonium CompoundsResins SyntheticElastomerschemistryGlutaralSilicone ElastomersDental impression materialGlutaraldehydebusiness
researchProduct