Search results for "electromyography"

showing 10 items of 672 documents

Grasp-specific motor resonance is influenced by the visibility of the observed actor

2016

AbstractMotor resonance is the modulation of M1 corticospinal excitability induced by observation of others' actions. Recent brain imaging studies have revealed that viewing videos of grasping actions led to a differential activation of the ventral premotor cortex depending on whether the entire person is viewed versus only their disembodied hand. Here we used transcranial magnetic stimulation (TMS) to examine motor evoked potentials (MEPs) in the first dorsal interosseous (FDI) and abductor digiti minimi (ADM) during observation of videos or static images in which a whole person or merely the hand was seen reaching and grasping a peanut (precision grip) or an apple (whole hand grasp). Part…

Research ReportAdultMalemedicine.medical_specialtyVisual perceptionAdolescentCognitive Neurosciencemedicine.medical_treatmentMovementClinical NeurologyExperimental and Cognitive PsychologyElectromyography050105 experimental psychologyVideosF5cPremotor cortex03 medical and health sciencesYoung Adult0302 clinical medicinePhysical medicine and rehabilitationHand strengthmedicineHumans0501 psychology and cognitive sciencesMuscle SkeletalMirror neuronmedicine.diagnostic_testHand StrengthElectromyography05 social sciencesGRASPMotor CortexAction observationEvoked Potentials MotorHandTranscranial Magnetic StimulationTranscranial magnetic stimulationNeuropsychology and Physiological Psychologymedicine.anatomical_structureMEPsNeurologyFemalePsychologyNeuroscienceMotor resonance030217 neurology & neurosurgeryPsychomotor PerformanceMotor cortexCortex; a Journal Devoted to the Study of the Nervous System and Behavior
researchProduct

Functional evaluation of a “lingual ring” oral device applied on patients affected by temporo-mandibular disorders tmds: A comparative clinical trial

2021

This study aims to evaluate the functional variations of the electromyographic response and clinical symptomatology in TMD patients. This study has been performed and compared before and after the application of a therapeutic protocol based on the use of an oral device working on the proper mandibular repositioning through the proprioceptive-based lingual re-education called “Lingual Ring”. Between January to December 2016, 32 TMD patients have been recruited out of a series of 321 individuals recruited at the Neurosensorial and Motorial Surgery Department, in Palermo (Italy). All the patients underwent the Surface Electromyography (sEMG) of Masseter and Temporal muscles, with different reg…

Ring deviceTechnologyMandibular DisordersQH301-705.5QC1-999Temporomandibular disorders (TMDs)ElectromyographyMuscular pain03 medical and health sciences0302 clinical medicineLingual ringstomatognathic systemCephalalgiaMedicineGeneral Materials ScienceBiology (General)QD1-999InstrumentationbookFluid Flow and Transfer ProcessesOrthodonticsbook.periodicalFunctional evaluationProprioceptionmedicine.diagnostic_testbusiness.industryTPhysicsProcess Chemistry and TechnologyGeneral Engineering030206 dentistryEngineering (General). Civil engineering (General)Computer Science ApplicationsClinical trialChemistrystomatognathic diseasesMedical devicesTA1-2040businessArticular pain030217 neurology & neurosurgery
researchProduct

Extracorporeal Stimulation of Sacral Nerve Roots for Observation of Pelvic Autonomic Nerve Integrity: Description of a Novel Methodological Setup.

2017

Introduction: Neurophysiologic monitoring can improve autonomic nerve sparing during critical phases of rectal cancer surgery. Objectives: To develop a system for extracorporeal stimulation of sacral nerve roots. Methods: Dedicated software controlled a ten-electrode stimulation array by switching between different electrode configurations and current levels. A built-in impedance and current level measurement assessed the effectiveness of current injection. Intra-anal surface electromyography (sEMG) informed on targeting the sacral nerve roots. All tests were performed on five pig specimens. Results: During switching between electrode configurations, the system delivered 100% of the set cur…

SacrumIntraoperative Neurophysiological MonitoringSwineBiomedical EngineeringAnal CanalStimulationElectromyographySignalExtracorporealPelvis03 medical and health sciences0302 clinical medicinemedicineAnimalsAutonomic PathwaysElectrical impedanceAutonomic nervemedicine.diagnostic_testbusiness.industryElectromyographyRectal NeoplasmsElectric StimulationAnode030220 oncology & carcinogenesisSacral nerve030211 gastroenterology & hepatologybusinessSpinal Nerve RootsOrgan Sparing TreatmentsBiomedical engineeringIEEE transactions on bio-medical engineering
researchProduct

Neck and Shoulder Muscle Activation Among Experienced and Inexperienced Pilots in +Gz Exposure

2017

Background The aim of the present study was to compare differences in electromyography (EMG) activation of the neck and shoulder muscles between groups of inexperienced and experienced pilots during controlled +Gz exposure in a centrifuge. Methods The subjects were volunteer cadets (inexperienced group) and lieutenants (experienced group) undergoing their first centrifuge training. The first group did not have any high performance aircraft (HPA) experience, while the latter one had a 1-yr experience of intense flying of HPA. During the centrifuge run, EMG activity was recorded from the left and right shoulder, neck flexor, and neck extensor muscles. Results The pilots without HPA experience…

Shoulderelectromyographymedicine.medical_specialtyhigh performance aircraftCentrifugationHypergravityElectromyographycervical spineYoung Adult03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationNeck MusclesHumHumansMedicine0501 psychology and cognitive sciences050102 behavioral science & comparative psychologyMuscle activityMuscle Skeletalta315VolunteerFinlandmedicine.diagnostic_testbusiness.industry05 social sciences030208 emergency & critical care medicineMuscle activationta3142General MedicineAnatomyShoulder muscleNeck musclesG forcePilotsMilitary PersonnelAerospace MedicineAviation medicinebusinessGravitationAerospace Medicine and Human Performance
researchProduct

Online signal processing of internal anal sphincter activity during pelvic autonomic nerve stimulation: a new method to improve the reliability of in…

2011

Aim  Intra-operative neuromonitoring is increasingly applied in several surgical disciplines and has been introduced to facilitate pelvic autonomic nerve preservation. Nevertheless, it has been considered a questionable tool for the minimization of risk, as the results are variable and might be misleading. The aim of the present experimental study was to develop an intra-operative neuromonitoring system with improved reliability for monitoring pelvic autonomic nerve function. Method  Fifteen pigs underwent low anterior rectal resection with pelvic autonomic nerve preservation. Intra-operative neuromonitoring was performed under autonomic nerve stimulation with observation of electromyograph…

Signal processingAutonomic nerveIntra-operative neuromonitoringmedicine.diagnostic_testbusiness.industryGastroenterologyStimulationElectromyographyFrequency spectrumInternal anal sphincterInterquartile rangeAnesthesiamedicinebusinessColorectal Disease
researchProduct

Transputer-based parallel system for acquisition and on-line analysis of single-fiber electromyographic signals.

1992

Abstract We describe a transputer-based system suitable for accurate measurements of single-fiber electromyographic jitter. It consists of a conventional electromyograph, a home-made interface and a commercially available transputer-based board installed within a PC/AT compatible. Taking advantage of the concurrent operation of two transputer modules, the system features simultaneous data acquisition and statistical signal processing: while data are acquired and analyzed, a real-time visualization of the signal latency and its variability is provided. In the present configuration, the system can acquire and analyze up to 40,000 consecutive action potentials, which can be grouped into up to …

Signal processingComputer scienceElectromyographyTransputerInterface (computing)Real-time computingHealth InformaticsSignal Processing Computer-AssistedSignalComputer Science ApplicationsData acquisitionMicrocomputersEvaluation Studies as TopicHumansDiagnosis Computer-AssistedSmoothingSoftwareStatistical signal processingJitterComputer methods and programs in biomedicine
researchProduct

Rechnerunterstützte Auswertung elektromyographischer und goniometrischer Meßsignale mit statistischen Signalanalyseverfahren

1998

Signal processingmedicine.diagnostic_testComputer scienceGoniometerBiomedical EngineeringmedicineElectromyographySignalBiomedical engineeringBiomedizinische Technik/Biomedical Engineering
researchProduct

Mechanical and neural stretch responses of the human soleus muscle at different walking speeds

2009

During human walking, a sudden trip may elicit a Ia afferent fibre mediated short latency stretch reflex. The aim of this study was to investigate soleus (SOL) muscle mechanical behaviour in response to dorsiflexion perturbations, and to relate this behaviour to short latency stretch reflex responses. Twelve healthy subjects walked on a treadmill with the left leg attached to an actuator capable of rapidly dorsiflexing the ankle joint. Ultrasound was used to measure fascicle lengths in SOL during walking, and surface electromyography (EMG) was used to record muscle activation. Dorsiflexion perturbations of 6 deg were applied during mid-stance at walking speeds of 3, 4 and 5 km h(-1). At eac…

Soleus musclePhysicsmedicine.diagnostic_testPhysiologyElectromyographyAnatomyMuscle stiffnessFasciclePreferred walking speedmedicine.anatomical_structuremedicineReflexStretch reflexTreadmillhuman activitiesBiomedical engineeringThe Journal of Physiology
researchProduct

The Hoffmann reflex of human plantar foot muscles

1998

Electrical stimulation of the tibial nerve in the popliteal fossa evoked an M wave (10.9 ms) and a late reflex response (38.1 ms) in the plantar foot muscles of all 10 volunteers. The late response had a somewhat lower electrical threshold than the corresponding M wave (8.5 versus 9 mA), and reached a maximum of amplitude when the stimulus intensity was increased, but was strongly suppressed by further increased intensity. A more distal stimulation of the tibial nerve at the ankle shortened the onset latency of the M wave and lengthened that of the late response. The reflex was facilitated by activation of synergists and inhibited by activation of antagonists. We showed that the late respon…

Soleus musclemedicine.diagnostic_testPhysiologybusiness.industryAnatomyElectromyographyF waveAnkle jerk reflexCellular and Molecular NeurosciencePhysiology (medical)ReflexMedicineAbductor hallucis muscleNeurology (clinical)H-reflexTibial nervebusinessMuscle & Nerve
researchProduct

2020

Even though the acute effects of pre-exercise static stretching and dynamic muscle activity on muscular and functional performance have been largely investigated, their effects on the corticospinal pathway are still unclear. For that reason, this study examined the acute effects of 5×20 s of static stretching, dynamic muscle activity and a control condition on spinal excitability, corticospinal excitability and plantar flexor neuromuscular properties. Fifteen volunteers were randomly tested on separate days. Transcranial magnetic stimulation was applied to investigate corticospinal excitability by recording the amplitude of the motor-evoked potential (MEP) and the duration of the cortical s…

Soleus musclemedicine.medical_specialtyMultidisciplinaryPyramidal tractsmedicine.diagnostic_testbusiness.industry030229 sport sciencesElectromyographyIsometric exerciseStatic stretching03 medical and health sciencesGastrocnemius muscle0302 clinical medicinemedicine.anatomical_structureInternal medicinemedicineCardiologyFunctional electrical stimulationmedicine.symptombusiness030217 neurology & neurosurgeryMuscle contractionPLOS ONE
researchProduct