Search results for "electron cyclotron resonance"
showing 10 items of 75 documents
Analysis of equations arising in gyrotron theory
2012
The gyrotron is a microwave source whose operation is based on the stimulated cyclotron radiation of electrons oscillating in a static magnetic field. Powerful gyrotrons can be used to heat nuclear fusion plasma. In addition, they have found a wide utility in plasma diagnostics, plasma chemistry, radars, extra-high-resolution spectroscopy, high-temperature processing of materials, medicine, etc. However, the main application of gyrotrons is in electron cyclotron resonance heating in tokamaks and stellarators. Equations describing gyrotron operation are ordinary differential equations and Schrödinger type partial differential equations. The present paper provides a survey of the analytical a…
Limitation of the ECRIS performance by kinetic plasma instabilities (invited).
2016
Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropic electron velocity distribution. The instabilities are associated with strong microwave emission and periodic bursts of energetic electrons escaping the magnetic confinement. The instabilities explain the periodic ms-scale oscillation of the extracted beam current observed with several high performance ECRISs and restrict the parameter space available for the optimization of extracted beam currents of highly charged ions. Experiments with the JYFL 14 GHz ECRIS have demonstrated that due to the instabilities the optimum Bmin-field is less than 0.8BECR, which is the value suggested by …
Transverse distribution of beam current oscillations of a 14 GHz electron cyclotron resonance ion source
2014
The temporal stability of oxygen ion beams has been studied with the 14 GHz A-ECR at JYFL (University of Jyvaskyla, Department of Physics). A sector Faraday cup was employed to measure the distribution of the beam current oscillations across the beam profile. The spatial and temporal characteristics of two different oscillation “modes” often observed with the JYFL 14 GHz ECRIS are discussed. It was observed that the low frequency oscillations below 200 Hz are distributed almost uniformly. In the high frequency oscillation “mode,” with frequencies >300 Hz at the core of the beam, carrying most of the current, oscillates with smaller amplitude than the peripheral parts of the beam. The result…
Limitations of electron cyclotron resonance ion source performances set by kinetic plasma instabilities.
2015
Electron cyclotron resonance ion source (ECRIS) plasmas are prone to kinetic instabilities due to anisotropy of the electron energy distribution function stemming from the resonant nature of the electron heating process. Electron cyclotron plasma instabilities are related to non-linear interaction between plasma waves and energetic electrons resulting to strong microwave emission and a burst of energetic electrons escaping the plasma, and explain the periodic oscillations of the extracted beam currents observed in several laboratories. It is demonstrated with a minimum-B 14 GHz ECRIS operating on helium, oxygen, and argon plasmas that kinetic instabilities restrict the parameter space avail…
Optimizing charge breeding techniques for ISOL facilities in Europe: conclusions from the EMILIE project
2015
ThuM07; International audience; The present paper summarizes the results obtained from the past few years in the framework ofthe Enhanced Multi-Ionization of short-Lived Isotopes for Eurisol (EMILIE) project. The EMILIEproject aims at improving the charge breeding techniques with both Electron Cyclotron ResonanceIon Sources (ECRIS) and Electron Beam Ion Sources (EBISs) for European Radioactive Ion Beam(RIB) facilities. Within EMILIE, an original technique for debunching the beam from EBIS chargebreeders is being developed, for making an optimal use of the capabilities of CW post-acceleratorsof the future facilities. Such a debunching technique should eventually resolve duty cycle andtime st…
Prospects for advanced electron cyclotron resonance and electron beam ion source charge breeding methods for EURISOL
2011
International audience; As the most ambitious concept of isotope separation on line (ISOL) facility, EURISOL aims at producing unprecedented intensities of post-accelerated radioactive isotopes. Charge breeding, which transforms the charge state of radioactive beams from 1+ to an n+ charge state prior to postacceleration, is a key technology which has to overcome the following challenges: high charge states for high energies, efficiency, rapidity and purity. On the roadmap to EURISOL, a dedicated R&D is being undertaken to push forward the frontiers of the present state-of-the-art techniques which use either electron cyclotron resonance or electron beam ion sources. We describe here the gui…
Plasma diagnostic tools for ECR ion sources : What can we learn from these experiments for the next generation sources
2019
International audience; The order-of-magnitude performance leaps of ECR ion sources over the past decades result from improvements to the magnetic plasma confinement, increases in the microwave heating frequency, and techniques to stabilize the plasma at high densities. Parallel to the technical development of the ion sources themselves, significant effort has been directed into the development of their plasma diagnostic tools. We review the recent results of Electron Cyclotron Resonance Ion Source (ECRIS) plasma diagnostics highlighting a number of selected examples of plasma density, electron energy distribution, and ion confinement time measurements, obtained mostly with the second-gener…
Measurement of the energy distribution of electrons escaping minimum-B ECR plasmas
2017
The measurement of the electron energy distribution (EED) of electrons escaping axially from a minimum-B electron cyclotron resonance ion source (ECRIS) is reported. The experimental data were recorded with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The electrons escaping through the extraction mirror of the ion source were detected with a secondary electron amplifier placed downstream from a dipole magnet serving as an electron spectrometer with 500 eV resolution. It was discovered that the EED in the range of 5–250 keV is strongly non-Maxwellian and exhibits several local maxima below 20 keV energy. It was observed that the most influential ion source operating pa…
Diagnostics of a charge breeder electron cyclotron resonance ion source helium plasma with the injection of 23 Na 1+ ions
2016
This work describes the utilization of an injected 23Na1þ ion beam as a diagnostics of the helium plasma of a charge breeder electron cyclotron resonance ion source. The obtained data allows estimating the upper limit for the ion-ion collision mean-free path of the incident sodium ions, the lower limit of ion-ion collision frequencies for all charge states of the sodium ions and the lower limit of the helium plasma density. The ion-ion collision frequencies of high charge state ions are shown to be at least on the order of 1–10 MHz and the plasma density is estimated to be on the order of 1011 cm−3 or higher. The experimental results are compared to simulations of the 23Na1þ capture into th…
Experimental evidence on microwave induced electron losses from ECRIS plasma
2018
The balance between warm and hot (>1 keV) electron density and their losses from the magnetic confinement system of an Electron Cyclotron Resonance Ion Source (ECRIS) plasma is considered to be one of the main factors determining the rate of the high charge state ion production. One of the key loss channels for heated electrons is thought to be induced by the injected microwaves. While this loss mechanism, referred to as rf-induced pitch angle scattering, has been studied theoretically and with computational tools, direct experimental evidence of its significance in minimum-B ECRIS plasmas remains limited. In this work, experimental evidence of microwave induced electron losses in the axial…