Search results for "elettrici"
showing 10 items of 959 documents
Back EMF Sensorless-Control Algorithm for High-Dynamic Performance PMSM
2010
In this paper, a low-time-consuming and low-cost sensorless-control algorithm for high-dynamic performance permanent-magnet synchronous motors, both surface and internal permanent-magnet mounted for position and speed estimation, is introduced, discussed, and experimentally validated. This control algorithm is based on the estimation of rotor speed and angular position starting from the back electromotive force space-vector determination without voltage sensors by using the reference voltages given by the current controllers instead of the actual ones. This choice obviously introduces some errors that must be vanished by means of a compensating function. The novelties of the proposed estima…
Automotive Brushless Motor Powered by Fuel Cell
2014
Impact of building automation control systems and technical building management systems on the energy performance class of residential buildings: An …
2014
Abstract The paper focuses on the evaluation of the impact on residential buildings of building automation control (BAC) and technical building management (TBM) systems. This work shows how the control, monitoring and automation functions considered by the European Standard EN 15232 can considerably influence the energy performance of a single-family test house and, consequently, its energy performance class. The study puts into evidence that the benefit that can be drawn from the installation of BAC and TBM systems depends on the type of technical appliances in the household and on the starting energy performance class. Finally, the economic impact due to the introduction of BACS or TBM fu…
Economic impact of BACS and TBM systems on residential buildings
2013
The paper presents the results of a study on the economic impact of building automation control systems and technical building management systems on residential buildings. The different functions considered by European Standard EN 15232 and having impact on the energy performance of buildings are applied to a test house, varying its energy efficiency class. The economic impact due to the introduction of each BACS or TBM function is evaluated using the BAC factors method, considering the real costs for the purchase and the installation of the components that implement the specific functions and the yearly energy costs of the building before and after their installation.
Demand side management and Distributed on Site actions benefits
2013
Global warming and energy demand are nowadays becoming one of the major issues of the third millennium, mainly because human activities seem to have a clear impact on the raise of CO2 emissions as never it has been experienced in the past. Among the different factors affecting CO2 emissions, energy demand from buildings constitutes one of the most important actors. Energy Management (EM) actions can reduce the energy consumption of the system and minimize peaks-level, by using a distributed control over every house. These local actions can greatly contribute to reduce the impact on the global CO2 emissions. An evaluation of the potential energy saving and CO2 emissions reduction on building…
ANALYSIS OF IMPACTS ON ELECTRIC POWER SYSTEM OPERATION OF LOAD MANAGEMENT IN RESIDENTIAL AND TERTIARY BUILDINGS
2012
Load management includes all the techniques, logics, actions and programs through which the electric utilities and the customers are able to manage loads absorption in a more prudent and efficient way; it determines economic benefits for the users, but also allows a network management and operation simpler and cheaper, determining technical and economic benefits. The present paper constitutes a detailed study of interventions and techniques to control demand in the residential and tertiary sectors and the effects that these actions have on the entire electrical system and its management. It discusses the implications of such control actions in terms of reduction of network losses and relate…
Investigating energy saving potential in a big shopping center through ventilation control
2019
Abstract This paper investigates energy saving measures for the ventilation system of large shopping centers. This kind of buildings is characterized by high yearly energy consumptions, because of the high level of operating hours and the frequent use of obsolete technologies. In the analyzed case studies, three big Do It Yourself (DIY) shops, located in Italy, are considered. Two different approaches are considered, they are aimed at reducing the annual energy consumption for the indoor air exchange of the sales area. The first considered retrofit solution consists in the installation of heat recovery exchangers, reducing the energy demand for the air thermal treatment without changing the…
Cascaded H-Bridges Multilevel Inverter Drive: Active Power Analysis in Frequency Domain
2022
The international standard IEC 61800-9-2 introduces energy efficiency classification for frequency converters or complete drive module (CDM) and provides instrumentation minimum requirements for accurate measurement of CDM input and output power valid for conventional pulse-width-modulated (PWM) voltage source inverter (VSI). This paper highlights the necessary improvements to update the standard with more detailed prescriptions according to the converter topologies and the modulation techniques adopted. In this framework, this paper address the power analysis in the frequency domain of a cascaded H-bridges-multilevel inverter (CHBMI) in an interior permanent magnet synchronous motor (IPMSM…
Experimental Evaluation of Dead-Time Impacts on the Efficiency and THD for a Three-Phase Five-Level Cascaded H-Bridge Inverter
2022
Cascaded H-Bridges Multilevel Inverter (CHBMI) is a fascinating solution for optimization purposes in several application fields. The CHBMI performance optimization can be reached both with hardware and software solutions. In detail, the CHBMI performances are a function of the modulation strategy adopted and its parameters such as modulation index, switching frequency, and dead time. This paper presents performance experimental analysis on dead time effects on CHBMI performance in terms of harmonic distortion and conversion efficiency. In this analysis, two different modulation strategies have been considered and implemented. The paper focuses on modulation strategies implemented, the test…
Field Oriented Control of IPMSM Fed by Multilevel Cascaded H-Bridges Inverter with NI-SOM sbRIO-9651 FPGA controller
2022
Electrical drives fed by Multilevel Inverters (MIs) are of considerable interest for traction and e-mobility applications. In detail, Cascaded H-Bridge Multilevel Inverter (CHBMI) is a promising solution for electrical drive optimization purposes in terms of efficiency, safety, integration and flexible use of energy sources. The aim of this paper is the experimental implementation of the field-oriented control strategy of Interior Permanent Magnet Synchronous Machine (IPMSM) fed by CHBMI by use of NI-SOM sbrRIO-9651 FPGA controller. This FPGA controller can be programmable in the LabVIEW programming environment with the consequent benefits of graphical programming. The paper address the acq…