Search results for "emission"

showing 10 items of 2441 documents

An ultrasound-assisted digestion method for the determination of toxic element concentrations in ash samples by inductively coupled plasma optical em…

2007

method of ultrasound-assisted digestion followed by inductively coupled plasma optical emission spectrometry (ICP-OES) used for the determination of toxic element concentrations (arsenic, barium, cobalt, copper, lead, nickel, strontium, vanadium and zinc) in ash samples was developed. All the measurements were performed in robust plasma conditions which were tested by measuring the Mg(II) 280.270 nm/Mg(I) 285.213 nm line intensity ratios. The highest line intensity ratios were observed when a nebulizer gas flow of 0.6 L minˉ¹, auxiliary gas flow of 0.2 L minˉ¹ and plasma power of 1400 W were used for radially viewed plasma. The analysis of SRM 1633b showed that the ultrasound-assisted metho…

mikroaaltomicrowavetuhkaemission spectrometryultrasoundashultraäänimyrkylliset alkuaineettoxic element
researchProduct

Influence on the transient evoked otoacoustic emission by GSM 915 MHz electromagnetic fields: comparative analysis between control and exposed groups

2006

mobile phonetransient evoked otoacustic emissionSettore MED/31 - OtorinolaringoiatriaSettore ING-INF/06 - Bioingegneria Elettronica E InformaticaGSM electromagnetic fieldSettore MED/32 - Audiologia
researchProduct

Towards a reduction of greenhouse gas emission from wastewater treatment plants: a new plant wide experimental and modelling approach

2016

The increasing interest in greenhouse gas (GHG) emissions from wastewater treatment plants (WWTPs) has led to the development of new tools for their design and management. Studies about gas emissions show that the sewer collection and the wastewater treatment plant are anthropogenic GHG potential sources, so they contribute to the climate change and air pollution. A wastewater treatment plant receives wastewater from sewers and, while produces treated water for discharge into surface water, emits the three major greenhouse gases, CO2, CH4, and N2O, during the treatment processes, and additional amounts of CO2 and CH4 from the energy demands (Bani Shahabadi et al., 2009). Indeed, energy cons…

modellingGHG emissionSettore ICAR/03 - Ingegneria Sanitaria-Ambientaleenergy consumptionDecision support system; energy consumptions; GHG emissions; modelling; WWTPsDecision support systemWWTPs
researchProduct

Enhancing Light Emission in Interface Engineered Spin-OLEDs through Spin-Polarized Injection at High Voltages

2019

The quest for a spin-polarized organic light-emitting diode (spin-OLED) is a common goal in the emerging fields of molecular electronics and spintronics. In this device, two ferromagnetic (FM) electrodes are used to enhance the electroluminescence intensity of the OLED through a magnetic control of the spin polarization of the injected carriers. The major difficulty is that the driving voltage of an OLED device exceeds a few volts, while spin injection in organic materials is only efficient at low voltages. The fabrication of a spin-OLED that uses a conjugated polymer as bipolar spin collector layer and ferromagnetic electrodes is reported here. Through a careful engineering of the organic/…

molecular spintronicsMaterials sciencePhysics::Instrumentation and Detectorsspin-OLED02 engineering and technologyElectroluminescence010402 general chemistry01 natural sciencesmultifunctional spintronic devicesCondensed Matter::Materials ScienceOLEDGeneral Materials ScienceSpin (physics)MaterialsDiodeSpintronicsSpin polarizationbusiness.industryMechanical EngineeringMolecular electronics021001 nanoscience & nanotechnologyspin-injection0104 chemical sciencesInnovacions tecnològiquesMechanics of MaterialsOptoelectronicsLight emissionCondensed Matter::Strongly Correlated Electrons0210 nano-technologybusinessAdvanced Materials
researchProduct

SHM of chemically bonded anchors by means of acoustic emission

2009

This paper presents a study on the use of acoustic emission (AE) to assess the structural soundness of concrete reinforced with chemically bonded anchors. The results of an experimental work based on six pullout tests monitored using AE are reported. In every test one rebar was embedded in hardened concrete by means of polyester resin. The AE was adopted to monitor the onset and progression of structural damage. The parametric analysis and the moment tensor analysis of AE data were used to discriminate among different sources of damage.

moment tensor analysisbonded anchoracoustic emission
researchProduct

Performance Enhancement of a Small Animal Positron Emission Tomograph based on Continuous Crystals and Silicon Photomultipliers

2017

La tomografía por emisión de positrones (PET, por sus siglas en inglés) es una técnica de Medicina Nuclear que permite obtener de manera no invasiva imágenes funcionales “in vivo” marcando un compuesto orgánico con un emisor de positrones. Los tomógrafos PET requieren un alta resolución espacial y sensibilidad para estimar con precisión la distribución del radiotrazador en el animal. Frente a los bloques pixelados comúnmente utilizados en PET, los detectores que consisten en la combinación de cristales continuos acoplados a fotodetectores segmentados pueden ofrecer una mayor eficiencia y una alta resolución espacial. Esta última depende de la precisión de los algoritmos de determinación de …

monte carlo simulationspositron emission tomography:FÍSICA [UNESCO]UNESCO::FÍSICAdepth of interactionmonolithic crystalssilicon photomultipliers
researchProduct

Highly-parallelized simulation of a pixelated LArTPC on a GPU

2023

The rapid development of general-purpose computing on graphics processing units (GPGPU) is allowing the implementation of highly-parallelized Monte Carlo simulation chains for particle physics experiments. This technique is particularly suitable for the simulation of a pixelated charge readout for time projection chambers, given the large number of channels that this technology employs. Here we present the first implementation of a full microphysical simulator of a liquid argon time projection chamber (LArTPC) equipped with light readout and pixelated charge readout, developed for the DUNE Near Detector. The software is implemented with an end-to-end set of GPU-optimized algorithms. The alg…

multiplication and inductionpulse formationscintillationtutkimuslaitteethiukkasfysiikkaelectric fieldsnoble liquid detectorscharge transportdetector modelling and simulations IIsimulation methods and programsMonte Carlo -menetelmätilmaisimetelectron emissiondouble-phaseprosessointiionizationalgoritmittime projection chamberssimulointiTPC
researchProduct

Adalimumab in active ulcerative colitis: A “real-life” observational study

2013

Abstract Background and aims The effectiveness of adalimumab in the treatment of ulcerative colitis is under debate. Although controlled trials have shown that adalimumab is significantly better than placebo, the absolute clinical benefit is modest. We report data on the effectiveness of adalimumab in a cohort of ulcerative colitis patients treated in 22 Italian centres. Methods All patients with active disease treated with adalimumab were retrospectively reviewed. Co-primary endpoints were clinical remission at weeks 4, 12, 24 and 54. Secondary endpoints were sustained clinical remission, steroid discontinuation, endoscopic remission and need for colectomy. Results Eighty-eight patients we…

musculoskeletal diseasesAdultMaleAdalimumab “Real-life” study Ulcerative colitismedicine.medical_specialtymedicine.medical_treatmentIBDAnti-Inflammatory AgentsAdalimumab; “Real-life” study; Ulcerative colitisAntibodies Monoclonal HumanizedPlaceboCohort StudiesYoung AdultRefractoryAdrenal Cortex HormonesInternal medicineAdalimumabmedicineHumansskin and connective tissue diseases“Real-life” studyRetrospective StudiesColectomySettore MED/12 - GastroenterologiaHepatologybusiness.industryRemission InductionSettore MED/09 - MEDICINA INTERNAGastroenterologyAdalimumabmedicine.diseaseUlcerative colitishumanitiesInfliximabSurgeryDiscontinuationTreatment OutcomeUlcerative colitisCohortColitis UlcerativeDrug Therapy CombinationFemalebusinessmedicine.drug
researchProduct

Case Report: Unmasking Hypercalcemia in Patients With Neuroendocrine Neoplasms. Experience From Six Italian Referral Centers

2021

BackgroundHypercalcemia is a common paraneoplastic syndrome which can occur in up to 10% of patients with advanced neoplasms. Paraneoplastic parathyroid hormone-related protein (PTHrP) represents the most frequent cause of this syndrome. In neuroendocrine neoplasms (NENs) paraneoplastic hypercalcemia is rare.Case SeriesThe present series includes all patients with NENs and paraneoplastic hypercalcemia from four Italian centres: (I) A 40-year-old man was hospitalized for repeated episodes of falls, hyposthenia and drowsiness. Severe hypercalcemia was found. Metastatic pancreatic G2 NEN and PTHrP-related hypercalcemia were diagnosed. The patient started therapy with somatostatin analogs (SSA)…

musculoskeletal diseasesAdultMalemedicine.medical_specialty125-dihydroxyvitamin Dbronchial carcinoidEndocrinology Diabetes and Metabolism1pancreatic NENCase ReportGastroenterologyDiseases of the endocrine glands. Clinical endocrinologyparaneoplastic hypercalcemia; parathyroid hormone-related protein; pancreatic nen; bronchial carcinoid; 125-dihydroxyvitamin dEndocrinologyparaneoplastic hypercalcemiaInternal medicinemedicineHumansVitamin DAgedEverolimusmedicine.diagnostic_testPerformance statusParathyroid hormone-related proteinbusiness.industryparathyroid hormone-related proteinMiddle AgedRC648-665PrognosisPancreatic NeoplasmsNeuroendocrine TumorsSomatostatinDenosumabPositron emission tomographyCalcitoninRadionuclide therapyHypercalcemiaFemalebusiness25-dihydroxyvitamin dhormones hormone substitutes and hormone antagonistsmedicine.drugFrontiers in Endocrinology
researchProduct

Estimation of structural and geometrical properties of cortical bone by computerized tomography in 78-year-old women

2009

The structural and geometrical properties of the tibia shaft were investigated at two sections by means of computerized tomography (CT) in 78-year-old women with high (n = 19) and low (n = 17) calcaneal bone mineral density (BMD, g/cm3) previously measured by 125I-photon absorption. The high BMD group had a 20-21% higher tibial BMD and 9-12% higher bone cross-sectional area than was observed in the low BMD group. The distribution of bone mass indicated that the low BMD group had lost bone mainly from the endosteal surface, especially in the anterior part of the tibia. However, both groups had a similar basic pattern of mass distribution at the measured sections. The high BMD group had highe…

musculoskeletal diseasesBone densityEndocrinology Diabetes and MetabolismBody Mass IndexFractures BoneAbsorptiometry PhotonBone DensityRisk FactorsmedicineAnimalsHumansOrthopedics and Sports MedicineTibiaAgedBone mineralOrthodonticsTibiaBody WeightBiomechanicsAnatomymusculoskeletal systemBiomechanical PhenomenaCalcaneusmedicine.anatomical_structureCattleFemaleCortical boneTomographyCalcaneusBody mass indexMathematicsTomography Emission-ComputedJournal of Bone and Mineral Research
researchProduct