Search results for "emmetrop"

showing 10 items of 39 documents

The Effect of Anesthetic Eye Drop Instillation on the Distribution of Corneal Thickness

2012

PURPOSE To address the effect of topical instillation of oxybuprocaine on the relative distribution of corneal thickness (CT) in young healthy subjects. METHODS Prospective study involving 30 eyes of 30 emmetropic subjects (24 ± 3 years). Corneal thickness measurements were carried out before and 3 minutes after the instillation of oxybuprocaine 4% using slit-scanning corneal topography (Orbscan topography system II). No acoustic correction factor was applied. The mean of 5 consecutive Orbscan measurements was obtained at the center and 3 mm from the visual axis in the temporal, superior, nasal, and inferior hemimeridians. RESULTS No significant mean differences were found at any corneal lo…

Malemedicine.medical_specialtyAdministration Topicalmedicine.medical_treatmentEmmetropiaTopical anestheticCorneaTonometry OcularYoung AdultOphthalmologyCorneamedicineHumansDistribution (pharmacology)Prospective StudiesAnesthetics LocalOxybuprocaineIntraocular Pressuremedicine.diagnostic_testbusiness.industryCorneal TopographyEye dropEmmetropiaCorneal topographyeye diseasesOphthalmologymedicine.anatomical_structureAnesthesiaAnestheticFemalesense organsOphthalmic SolutionsbusinessProcainemedicine.drugCornea
researchProduct

Clear Lens Extraction with Multifocal Apodized Diffractive Intraocular Lens Implantation

2007

Purpose To assess efficacy, safety, predictability, and stability after clear lens extraction (CLE) with multifocal diffractive intraocular lens (IOL) implantation. Design Prospective, nonrandomized, masked observational case series (self-controlled). Participants Two hundred twenty-four eyes of 112 consecutive patients after CLE with bilateral AcrySof ReSTOR Natural IOL implantation. Eyes were divided into myopic (mean spherical equivalent [SE], −6.01±2.71 diopters [D]) and hyperopic (mean SE, +3.86±2.52 D) groups. Methods Monocular and binocular uncorrected distance visual acuity (VA), best-corrected distance VA, uncorrected distance near VA, and best distance-corrected near VA were recor…

Malemedicine.medical_specialtyDistance visual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityEmmetropiaIntraocular lensProsthesis DesignOphthalmoscopyTonometry OcularLens Implantation IntraocularOphthalmologyLens CrystallineMyopiamedicineHumansProspective StudiesDioptreAgedLenses IntraocularClear lens extractionPhacoemulsificationmedicine.diagnostic_testbusiness.industryPhacoemulsificationPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmoscopyOphthalmologyHyperopiaTreatment OutcomeOptometryFemalesense organsbusinessOphthalmology
researchProduct

Relationship among Corneal Biomechanics, Refractive Error, and Axial Length

2014

Purpose To evaluate the relationship between different ocular and corneal biomechanical parameters in emmetropic and ametropic healthy white children. Methods This study included 293 eyes of 293 healthy Spanish children (135 boys and 158 girls), ranging in age from 6 to 17 years. Subjects were divided according to the refractive error: control (emmetropia, 99 children), myopia (100 children), and hyperopia (94 children) groups. In all cases, corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer system. Axial length (AL) and mean corneal power were also measured by partial coherence interferometry (IOLMaster), and central corneal thickne…

Malemedicine.medical_specialtyRefractive errorIntraocular pressureocular parametersAdolescentgenetic structuresAnterior ChamberVisual AcuityEmmetropiaCorneachildrenOphthalmologyHumansMedicinerefractive errorChildIntraocular PressureDioptreÓpticabusiness.industryBiomechanicsHigh myopiaAxial lengthElastic TissueRefractive Errorsmedicine.diseaseeye diseasesBiomechanical PhenomenaAxial Length EyeOphthalmologyCross-Sectional Studiesagecorneal biomechanical propertiesRegression AnalysisOptometryFemaleMultiple linear regression analysissense organsbusinessTomography Optical CoherenceOptometryOptometry and Vision Science
researchProduct

Effect of sport-tinted contact lenses for contrast enhancement on retinal straylight measurements

2008

PURPOSE: To investigate the effect of two tinted contact lenses (CL) designed for outdoor sports activity on the psychometric determination of retinal straylight using the compensation comparison method. METHODS: Thirteen emmetropic subjects were randomly fitted with two different tinted Nike Maxsight (Bausch & Lomb, Rochester, NY, USA) CL in one eye, while the contralateral eye was fitted with a clear lens made of the same material (Optima 38, Bausch & Lomb). Three valid straylight measurements were taken on each eye before and a few minutes after lens insertion, when lens stabilization had occurred. RESULTS: The subjects' mean straylight values were 0.90 +/- 0.09 at baseline and 0.95 +/- …

Maleretinal straylightgenetic structuresPolymaconEmmetropiatinted lenslaw.inventionSports Equipmentchemistry.chemical_compound0302 clinical medicinelawScattering RadiationContrast (vision)media_commonSpectral filtersVision TestsEquipment DesignSensory SystemsLens (optics)Regression AnalysisFemalePhotopic visionAdultmedicine.medical_specialtyPsychometricsContact Lensescontact lensmedia_common.quotation_subjectLight scatterColorRetinaStatistics NonparametricContrast Sensitivity03 medical and health sciencesTinte contact lensOcular straylightOphthalmologymedicineHumansOcular straylightElectronic Data ProcessingScience & TechnologyRetinalContact lensOphthalmologyocular scatterchemistrypolymacon030221 ophthalmology & optometryOptometry030217 neurology & neurosurgeryOptometryOphthalmic and Physiological Optics
researchProduct

Ocular Refraction at Birth and Its Development During the First Year of Life in a Large Cohort of Babies in a Single Center in Northern Italy

2020

The purpose of this study was to investigate refraction at birth and during the first year of life in a large cohort of babies born in a single center in Northern Italy. We also aimed to analyze refractive errors in relation to the gestational age at birth. An observational ophthalmological assessment was performed within 24 h of birth on 12,427 newborns. Refraction was examined using streak retinoscopy after the administration of tropicamide (1%). Values in the range of between +0.50 ≤ D ≤ +4.00 were defined as physiological refraction at birth. Newborns with refraction values outside of the physiological range were followed up during the first year of life. Comparative analyses were condu…

Pediatricsmedicine.medical_specialtynewbornsgenetic structuresEmmetropiaamblyopia; newborns; physiological refraction; preterm babies; refractive screeningpreterm babieSingle CenterPediatricsnewbornphysiological refractionMedicineRetinoscopyOriginal ResearchAnisometropiaamblyopiamedicine.diagnostic_testrefractive screeningbusiness.industryCongenital myopialcsh:RJ1-570Gestational agelcsh:Pediatricspreterm babiesmedicine.diseaseRefractioneye diseasesPediatrics Perinatology and Child HealthGestationbusinessFrontiers in Pediatrics
researchProduct

Clinical use of the ocular point spread function for retinal image quality assessment

2008

The purpose of this study is to demonstrate the clinical use of the point spread function (PSF) as metric for the assessment of retinal image quality in eyes with different ocular conditions. The PSF was computed from the wavefront aberrations obtained in seven eyes with different ocular conditions: emmetropia, myopia, hyperopia, post-myopic laser in situ keratomileusis (LASIK), post-hyperopic LASIK, keratoconus, Intacs ® in keratoconus, radial keratotomy (RK), LASIK after RK, cataract, phacoemulsification after cataract surgery, and LASIK after astigmatic keratotomy. The Strehl intensity ratio was calculated for all the PSFs computed. The PSF was correlated with the change in the optical e…

Point spread functionKeratoconusmedicine.medical_specialtygenetic structuresbusiness.industrymedicine.medical_treatmentBiomedical EngineeringEmmetropiaLASIKStrehl ratioKeratomileusismedicine.diseaseeye diseasesOphthalmologyRadial keratotomyRefractive surgeryOphthalmologyMedicineOptometrysense organsbusinessOptometryExpert Review of Ophthalmology
researchProduct

Genetic variants linked to myopic macular degeneration in persons with high myopia: CREAM Consortium.

2019

Purpose: To evaluate the roles of known myopia-associated genetic variants for development of myopic macular degeneration (MMD) in individuals with high myopia (HM), using case-control studies from the Consortium of Refractive Error and Myopia (CREAM). Methods: A candidate gene approach tested 50 myopia-associated loci for association with HM and MMD, using meta-analyses of case-control studies comprising subjects of European and Asian ancestry aged 30 to 80 years from 10 studies. Fifty loci with the strongest associations with myopia were chosen from a previous published GWAS study. Highly myopic (spherical equivalent [SE] ≤ -5.0 diopters [D]) cases with MMD (N = 348), and two sets of cont…

Refractive errorCandidate genegenetic structuresEmmetropiaGenome-wide association studySensory disorders Donders Center for Medical Neuroscience [Radboudumc 12]Macular DegenerationMathematical and Statistical TechniquesMedicine and Health SciencesMyopiaGeriatric OphthalmologyDioptreVisual ImpairmentsAged 80 and overMultidisciplinaryQRetinal DegenerationStatisticsRGenomicsMetaanalysisPhenotypeResearch DesignPhysical SciencesMedicineRetinal DisordersFemaleAnatomyResearch Articlemedicine.medical_specialtyScienceOcular AnatomySingle-nucleotide polymorphismResearch and Analysis MethodsRetinaOcular SystemOphthalmologyGeneticsGenome-Wide Association StudiesmedicineHumansStatistical Methodsbusiness.industryGene Expression ProfilingCase-control studyBiology and Life SciencesComputational BiologyGenetic VariationCorrectionHuman GeneticsMacular degenerationGenome Analysismedicine.diseaseeye diseasesOphthalmologyGenetic LociGeriatricsMacular DisordersCase-Control StudiesEyessense organsbusinessHeadMathematicsPloS one
researchProduct

Pràctica 1. Presbícia. Laboratori d'Òptica Fisiològica

2023

El document forma part dels materials docents programats mitjançant l'ajut del Servei de Política Lingüística de la Universitat de València. Aquest és un guió de la pràctica 1 de l'assignatura d'Òptica Fisiògica, on s'aborda com estudiar i comprovar al laboratori què els passa als pacients prèsbites, i com cal compensar-los òpticament per a que funcionen bé, treballant amb un model d'ull simplificat i un altre de reduït. This is a script for practice 1 of Physiological Optics subject. In it, we addressed how to study and check in the laboratory what happens with presbyopic patients, and how to compensate them optically so that they work well. To do it, we will work with a simplified eye mod…

UNESCO::FÍSICApresbíciaaddicióemmetrop
researchProduct

Neural Adaptation to Optical Quality Defects

2010

From an optical perspective the eye is far from perfect. This is a fact that is extensively supported by literature; for instance, Prof. Navarro recently provided us with a fantastic critical review on the various theories behind the different eye models and their flaws.1 The human eye has considerable amounts of higher-order aberrations even when it is emmetropic,2 with great inter-individual variability. Besides, higher-order aberrations are still postulated to have a role in the development of the refractive error, although it is not clear the extent to which this may be (see Charman WN for a review).3 The known optical limitations of the normal human eye raised the question as to what t…

WavefrontRefractive errorgenetic structuresbusiness.industryComputer scienceImage qualityNeural adaptationPerspective (graphical)EmmetropiaAdaptation (eye)medicine.diseaseeye diseasesEditorialmedicine.anatomical_structurelcsh:Ophthalmologylcsh:RE1-994medicinelcsh:QC350-467Computer visionHuman eyeArtificial intelligencebusinesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct

Pràctica 1: Emmetropia i presbícia

2021

El document forma part dels materials docents programats mitjançant l'ajut del Servei de Política Lingüística de la Universitat de València. Guió de la primera pràctica de l'assignatura d'Òptica Fisiològica del Grau d'Òptica i Oprtometria de la Universitat de València Script of the first practice of Physiological Optics subject of the Optics and Optometry Degree of the University of Valencia

acomodacióUNESCO::FÍSICApresbíciaaddiciópunt pròximemmetropiapunt remot
researchProduct