Ocular performance evaluation
2019
Real and virtual three-dimensional (3D) imaging has found useful applications across different areas of health sciences and with the current rapidly progressive development stage we can expect that the use of 3D imaging soon will be a part of a daily visual load for medical personnel. To better understand the possible impact of prolonged work with 3D content on eye accommodative response and pupil size we compared two 3D imaging techniques - volumetric display that is real voxel-based system and anaglyph technique that is virtual pixel-based system. We have investigated accommodative lag and pupil responses in 38 emmetropic young adult after prolonged visual task with volumetric 3D display …
Heredity of interocular similarities in components of refraction: a population-based twin study among 66- to 79-year-old female twins.
2019
Purpose: To examine genetic influences on interocular similarities in ocular refraction and components of refraction among elderly female twins. Methods: Refraction was assessed in 94 monozygotic (MZ) and 74 dizygotic (DZ) female twins aged 66–78 years. Absolute values of interocular differences (Aniso variables) in spherical refraction (SR), refractive astigmatism (AST), spherical equivalent (SE), corneal refractive power (CR), corneal astigmatism (CAST), anterior chamber depth (ACD) and axial length (AL) were calculated. The differences between sisters in each of the Aniso variables were calculated and graded into two categories, best differentiating the groups, here isometropic and aniso…
Implantable collamer lens with central hole: 3-year follow-up.
2018
Luis Fernández-Vega-Cueto,1 Carlos Lisa,1 José J Esteve-Taboada,2 Robert Montés-Micó,2 José F Alfonso1,3 1Department of Surgery, Fernández-Vega Ophthalmological Institute, Oviedo, Spain; 2Department of Optics and Optometry and Visual Sciences, University of Valencia, Valencia, Spain; 3School of Medicine, University of Oviedo, Oviedo, Spain Purpose: To evaluate the long-term predictability, stability, safety, and efficacy of the V4c Visian implantable collamer lens (ICL) with central hole to correct myopia.Patients and methods: One hundred and eighty-four eyes of 92 patients were evaluated during 3 years after implantation of …
Evaluation of Shared Genetic Susceptibility to High and Low Myopia and Hyperopia
2021
Importance: Uncertainty currently exists about whether the same genetic variants are associated with susceptibility to low myopia (LM) and high myopia (HM) and to myopia and hyperopia. Addressing this question is fundamental to understanding the genetics of refractive error and has clinical relevance for genotype-based prediction of children at risk for HM and for identification of new therapeutic targets. Objective: To assess whether a common set of genetic variants are associated with susceptibility to HM, LM, and hyperopia. Design, Setting, and Participants: This genetic association study assessed unrelated UK Biobank participants 40 to 69 years of age of European and Asian ancestry. Par…
Variations of OCT measurements corrected for the magnification effect according to axial length and refractive error in children
2018
Purpose: The aim of this paper was to examine the distribution of macular, retinal nerve fiber layer (RNFL) thickness and optic disc parameters of myopic and hyperopic eyes in comparison with emmetropic control eyes and to investigate their variation according to axial length (AL) and spherical equivalent (SE) in healthy children. Methods: This study included 293 pairs of eyes of 293 children (145 boys and 148 girls), ranging in age from 6 to 17 years. Subjects were divided according to SE in control (emmetropia, 99 children), myopia (100 children) and hyperopia (94 children) groups and according to axial AL in 68 short ([Formula: see text]22.00[Formula: see text]mm, 68), medium (from [For…
Anterior chamber depth measurement in teenagers. Comparison of two techniques
2013
Purpose: The aim of this study is to determine the anterior chamber depth (ACD) in teenagers using two different devices: partial coherence interferometry IOLMaster (Carl Zeiss Meditec) and anterior segment optical coherence tomography (Visante TM OCT, Carl Zeiss Meditec) and to evaluate the degree of agreement between ACD measurements carried out by both instruments. Methods: In this prospective study 68 eyes of 34 emmetropic Caucasic patients (18 girls and 16 boys) were analysed. ACD was measured from the anterior corneal surface to anterior surface of the crystalline lens. For each age the ACD size was calculated and the difference between IOLMaster and Visante-OCT measurements was analy…