Search results for "equipment and supplies"
showing 10 items of 483 documents
Implantation of a toric poly(methyl methacrylate) intraocular lens to correct high astigmatism
1999
Abstract A 57-year-old man experienced a decrease in visual function because of cataract formation. Corneal astigmatism was 13.4 diopters (D) because he had had a penetrating keratoplasty 27 years before. Cataract surgery was planned, and biometric data for toric intraocular lens (IOL) implantation were collected for the manufacture of a custom IOL. After phacoemulsification, a toric poly(methyl methacrylate) (PMMA) IOL of +19.0 D spherical and +12.0 D cylindrical power was implanted via a sclerocorneal tunnel incision. Three months postoperatively, corneal astigmatism was 14.3 D and best corrected visual acuity (BCVA), 20/25. Postoperative refraction (+1.5 −3.0 × 90) and BCVA remained stab…
Combining Sirolimus-eluting Stents and External Irradiation in Cholesterol-fed Rabbits Increased Incomplete Stent Apposition and Decreased Re-endothe…
2009
Restenosis after the implantation of a drug-eluting stent or after vascular irradiation therapy shares similar physiopathological mechanisms. No experimental data are currently available on vascular wall behavior after external irradiation on arteries stented with sirolimus-eluting stents (SES). Ten New Zealand white rabbits received a 0.5% cholesterol-enriched chow for 1 month. Bilateral iliac artery stent implantation was then performed with an SES (Cypher; Cordis Corp). The animals were randomized into either an irradiated group (I, 2 Gy external x-ray irradiation, n = 5) or a control group (C, n = 5). The cholesterol-enriched chow was continued for 1 additional month after stent implant…
Optical Coherence Tomography Versus Intravascular Ultrasound to Evaluate Coronary Artery Disease and Percutaneous Coronary Intervention
2013
ObjectivesWe compared intravascular ultrasound (IVUS) and 2 different generations of optical coherence tomography (OCT)—time-domain OCT (TD-OCT) and frequency-domain OCT (FD-OCT)—for the assessment of coronary disease and percutaneous coronary intervention (PCI) using stents.BackgroundOCT is a promising light-based intravascular imaging modality with higher resolution than IVUS. However, the paucity of data on OCT image quantification has limited its application in clinical practice.MethodsA total of 227 matched OCT and IVUS pull backs were studied. One hundred FD-OCT and IVUS pull backs in nonstented (n = 56) and stented (n = 44) vessels were compared. Additionally, 127 matched TD-OCT and …
Radiolucent Carbon Fiber–Reinforced Pedicle Screws for Treatment of Spinal Tumors: Advantages for Radiation Planning and Follow-Up Imaging
2016
Objective Surgical treatment of spinal tumors regularly includes spinal instrumentation with pedicle screws. Most modern pedicle screws are made of titanium alloy, which is associated with artifacts on postoperative imaging such as computed tomography and/or magnetic resonance imaging. These artifacts hamper radiation treatment planning and execution and follow-up imaging. Recently, carbon fiber–reinforced polyetheretherketone (CFRP) implants became available for posterior instrumentation with the aim to reduce imaging artifacts by implants. Methods Patients harboring spinal tumors underwent posterior stabilization using CFRP pedicle screws. Postoperative imaging was evaluated for implant a…
Usefulness of multislice computed tomography to assess patency of coronary artery stents versus conventional coronary angiography
2008
BACKGROUND: The aim of the present study was to assess the in-stent restenosis and occlusion of coronary artery stents by multislice computed tomography (MSCT) compared with conventional coronary angiography in patients with atypical chest pain and not practicable/non-conclusive stress test. METHODS: Between December 2004 and March 2006, 81 patients were scheduled and of these 72 (65 men, mean age 61 years) with 90 stents underwent MSCT angiography using a 16-slice scanner, Toshiba Aquilion 16, 8-12 months after stent placement. RESULTS: Of the 90 stents, 71 (79%) could be assessed and 19 (21%) were excluded because the image quality at the stent level was incompatible with diagnostic asses…
Results of intracoronary stents for management of coronary dissection after balloon angioplasty.
1991
Dissections after coronary balloon angioplasty are risk factors for acute or subacute vessel closures. Intracoronary stenting was developed to avoid these complications by pressing the intimal and medial flaps against the vessel wall, thus reducing the risk of acute thrombosis. A total of 22 stents were implanted into the coronary arteries of 15 patients with dissections after balloon angioplasty causing angina pectoris or ischemic electrocardiographic changes. Stent delivery was successful in all cases. In 1 patient acute stent thrombosis was documented and treated successfully by thrombolytic therapy. Another patient underwent coronary artery bypass surgery 24 hours later because of persi…
Prospective, randomized, single-center trial comparing 3 different 10F plastic stents in malignant mid and distal bile duct strictures.
2003
Abstract Background: The aim of this study was to determine whether patency rates differ with respect to the material, design, and surface texture of 3 different plastic stents. Methods: A total of 120 patients (median age 70.5 years; interquartile range 62-78 years) with malignant mid or distal bile duct strictures, seen between March 1996 and May 1999, were prospectively randomized to receive a 10F polyurethane stent, a Teflon Tannenbaum stent, or a hydrophilic hydromer-coated polyurethane stent. The primary study outcome measure was the interval between stent insertion and the first episode of clogging (or the presence of jaundice at death without stent exchange). All 3 types of stent we…
Number and Locations of Screw Fixation for Volar Fixed-Angle Plating of Distal Radius Fractures: Biomechanical Study
2010
Purpose To compare the biomechanical properties of different numbers and locations of screws in a multidirectional volar fixed-angle plate in a distal radius osteotomy cadaver model. Methods We created an extra-articular fracture in 16 pairs of fresh-frozen human cadaver radiuses. The 32 specimens were randomized into 4 groups. All fractures were fixated with a multidirectional volar fixed-angle plate. We tested 4 different screw-placement options in the distal fragment. The distal fragment was fixed with 4 locking screws in the distal row of the plate in group a, and with 4 locking screws alternately in the distal and proximal rows in group b. In group c, 3 locking screws were used in the …
Is there a role for percutaneous pelvic and acetabular reconstruction?
2007
The primary goal in the treatment of pelvic fractures is the restoration of haemodynamic stability. The secondary goal is the reconstruction of stability and symmetry of the pelvic ring. Percutaneous reconstruction can only be accepted if these goals are met. The type of definitive surgery is dependent of the degree of instability of the anterior and posterior pelvic ring. Retrograde transpubic screw fixation of pubic rami fractures is a good alternative to external fixation or plate and screw osteosynthesis. The technique of screw placement and image intensifier control is explained. Internal fixation of pure sacroiliac dislocations, fracture-dislocations of the sacroiliac joint and sacral…
Secondary Osseous Integration of Cementless Unicompartmental Knee Arthroplasty After Internal Fixation of a Felix Type IIIB Fracture
2021
Case A 76-year-old man presented with periprosthetic tibial plateau fracture (TPF), with a completely loosened tibial component 3 weeks after cementless unicompartmental knee arthroplasty (UKA). Internal fixation by buttress plating was performed, and the tibial component was retained and left in situ primarily as a spacer. Revision was planned after fracture consolidation, but at 3 months, the patient was able to walk without support, without pain, and with full range of motion. At 1 year, he is free of complaints. The initial loosened tibial component reintegrated. Conclusion Internal fixation combined with preserving the loosened tibial component may be a treatment option for TPF involvi…