Search results for "error"
showing 10 items of 1643 documents
Mesopic Contrast Sensitivity Function After Laser in situ Keratomileusis
2003
ABSTRACT PURPOSE: To evaluate contrast sensitivity under mesopic conditions in patients who have undergone uncomplicated bilateral laser in situ keratomileusis (LASIK) for myopia. METHODS: Best-corrected monocular contrast sensitivity was measured with the Stereo Optical F.A.C.T. chart at 1.5, 3, 6, 12, and 18 c/deg in 20 patients (20 left eyes) before and after bilateral LASIK (with the Nidek EC-5000 excimer laser and the Automated Corneal Shaper). Mean preoperative refractive error was -6.40 ± 1.28 D (range -4.00 to -8.00 D) and postoperative mean refractive error was -0.41 ± 0.45 D (range -0.75 to +0.50 D). Contrast sensitivity function was measured before and 6 months after surgery usin…
Iris Claw Phakic Intraocular Lens for High Myopia
1997
ABSTRACT BACKGROUND: The implantation of a WorstFechner iris claw intraocular lens (IOL) is one of the surgical procedures used for the correction of high myopia. This technique reduces myopia with stähle refractive results; however, its potential long-term risks have not been evaluated. We report results in 94 eyes with a minimum follow -up of 3 years. METHODS: We studied 94 eyes of 62 patients with myopia 5= -7.00 diopters (D) who underwent Worst-Fechner IOL implantation. Lens decentration, permeability of the blood-aqueous barrier by iris angiography, and changes in corneal endothelial density were analyzed. RESULTS: Mean follow-up time was 48.9 months (range 36 to 72 mo). Three years af…
Long-term results of surgical treatment of high myopia with Worst-Fechner intraocular lenses
1995
Abstract This retrospective study evaluated the results in 90 eyes that had a minus-power anterior chamber intraocular lens implanted to correct high myopia. Preoperative myopia ranged from −7.00 to −24.00 D. Postoperative spherical equivalent was −0.50 D; 80.5% of eyes were within 1.00 D of emmetropia. Two years postoperatively, no cataract formation, retinal detachment, glaucoma, or significant endothelial damage had occurred. We conclude that minus-power lenses can rapidly, safely, and predictably correct high myopia in phakic patients.
Excimer laser photorefractive keratectomy for high myopia
1995
Abstract One hundred and thirty-three eyes of 103 patients had photorefractive keratectomy with a slit scan mode excimer laser for myopia ranging from −6.00 to −22.00 diopters (D). The epithelium was removed with 20% ethanol, and the ablation was done with a tapered profile surrounding the optical zone. Patients were divided into two groups based on preoperative myopia: Group A, −6.00 D to −12.00 D (88 eyes); Group B, −12.50 D to −22.00 D (45 eyes). In Group A, mean preoperative refraction was −9.59 ± 1.79 D. Mean postoperative refraction was −0.29 ± 1.47 D at one month, −0.85 ± 1.68 D at three months, −1.17 ± 2.04 D at six months, and −0.56 ± 0.74 D at one year. Anterior stromal haze was g…
Prevalence of corneal astigmatism before cataract surgery.
2008
To analyze the prevalence and presentation patterns of corneal astigmatism in cataract surgery candidates.University of Valencia, Valencia, Spain.Refractive and keratometric values were measured before surgery in patients having cataract extraction. Descriptive statistics of refractive and keratometric cylinder data were analyzed and correlated by age ranges.Refractive and keratometric data from 4,540 eyes of 2,415 patients (mean age 60.59 years +/- 9.87 [SD]; range 32 to 87 years) differed significantly when the patients were divided into 10-year subsets. There was a trend toward less negative corneal astigmatism values, except the steepest corneal radius and the J(45) vector component, in…
Endothelial study of iris-claw phakic lens: four year follow-up.
1998
Abstract Purpose: To study quantitative and morphometric endothelial changes in phakic eyes implanted with the Worst iris-claw lens to correct high myopia. Setting: Department of Ophthalmology, University Hospital “La Fe”, Valencia, Spain. Material and Methods: This retrospective study involved 111 phakic eyes (73 patients) implanted with the Worst iris-claw lens. Noncontact specular microscopy and computer-assisted analysis was performed preoperatively and 6 months and 1, 2, 3, and 4 years postoperatively. Results: The mean cell loss was 3.85% at 6 months, 6.59% at 1 year, 9.22% at 2 years, 11.68% at 3 years, and 13.42% at 4 years. At 2 years, the hexagonality and coefficient variation in …
Sleep disturbances in Angelman syndrome: a questionnaire study.
2003
Only few studies are available on sleep disorders in Angelman syndrome (AS), a neurodevelopmental disorder with several behavior disturbances. The aim of this study was to determine the prevalence of sleep disorders in a relatively large group of AS subjects, compared to that of age-matched controls. Forty-nine consecutive parents of patients with AS (26 males and 23 females aged 2.3-26.2 years) were interviewed and filled out a comprehensive sleep questionnaire. Based on their genetic etiology, four groups were defined: deletion of chromosome 15q11-13 (25 subjects); methylation imprinting mutation (six subjects), UBE3A mutations (seven subjects) and paternal uniparental disomy (five subjec…
Proactive interference of a sequence of tones in a two-tone pitch comparison task
2000
Subjects compared pitches of a standard tone and a comparison tone separated by 1,300-3,000 msec and responded according to whether the comparison tone sounded higher or lower in pitch than the standard tone. Three interfering tones at 300-msec intervals were presented before each pair of tones. Their pitch range varied, being either below or above the pitch of the standard tone; in some of the trials, their pitches were identical to the pitch of the standard tone (no interference). The highest error rate in performance was found when the interfering tones and the comparison tone deviated in the same direction in pitch from the standard tone. In turn, their deviations in the opposite direct…
Online detection of rem sleep based on the comprehensive evaluation of short adjacent eeg segments by artificial neural networks
1997
Abstract 1. 1. For scientific and clinical requirements the present objective is a robust automatic online algorithm to detect rapid eye movement (REM) steep from single channel sleep EEG data without using EMG or EOG information. 2. 2. For data preprocessing 20 seconds time periods of the continuous EEG activity are digitally filtered in 7 frequency bands. Then the RMS values of these filtered signals are calculated along segments of 2.5 seconds. The resulting matrix of RMS values is representing information on the power of the signal localized in time and frequency and serves as input to an artificial neural network. A pooled set of EEG data together with the corresponding manual evaluati…
Frameless Neuronavigation Applied to Endoscopic Neurosurgery
2000
Objective: We retrospectively analyzed the indications, surgical techniques, and applicability of frameless neuronavigation to endoscopic procedures in a heterogeneous group of 15 patients. Material and Methods: In 8 patients indications for surgery were cystic lesions, in 3 patients intraventricular tumors, and in 4 patients occlusive hydrocephalus. The mean age was 39 years (range 9 - 76 years). The follow-up period ranged from 5 - 24 months (mean 10 months). Frameless neuronavigation was accomplished with the “operating arm system” in 10 cases and with the “optical tracking system” in 5 cases (RADIONICS, Burlington, USA). Results: In all 15 cases, neuronavigation sufficiently provided an…