Search results for "ethylamine"
showing 10 items of 230 documents
Detection and characterization of emerging psychoactive substances by ion mobility spectrometry
2014
Rapid detection and identification of novel psychoactive substances (NPS) continues to present significant analytical challenges to forensic and analytical chemists. Ion mobility spectrometry (IMS) has been traditionally considered as the analytical technique of choice to detect illicit drugs in security points in airports, borderlines and customs. Databases of the reduced mobility (K0 ) values of illicit drugs are available in the scientific literature and they should be completed with data of emerging designer drugs. In this paper, we have evaluated the effect of different measurement conditions and determined the K0 values of an important number of NPS including different families; such …
Gaining insight in the behaviour of imidazolium-based ionic liquids as additives in reversed-phase liquid chromatography for the analysis of basic co…
2015
In reversed-phase liquid chromatography in the absence of additives, cationic basic compounds give rise to broad and asymmetrical peaks as a result of ionic interactions with residual free silanols on silica-based stationary phases. Ionic liquids (ILs), added to the mobile phase, have been suggested as alternatives to amines to block the activity of silanols. However, the dual character of ILs should be considered: both cation and anion may be adsorbed on the stationary phase, thereby creating a double asymmetrical layer positively or negatively charged, depending on the relative adsorption of both ions. In this work, a study of the performance of six imidazolium-based ILs (the chlorides an…
Seafood freshness determination through vapour phase Fourier transform infrared spectroscopy.
2006
Abstract A new vapour-phase manifold has been developed to determine trimethylamine (TMA) in fish and cephalopod samples by Fourier transform infrared (FT-IR) spectroscopy. Samples were treated off-line for 1 h with trichloroacetic acid (TCA), filtered and washed. The obtained extracts were aspirated and alkalinized with NaOH 2.0 M, in an on-line system. TMA was separated from the solution in a gas phase separator and then transported by means of a nitrogen carrier into a home made 10 cm pathlength IR gas cell, where the corresponding FT-IR spectra were acquired by accumulating 30 scans per spectrum with 2 cm−1 nominal resolution. The method was applied to the determination of TMA in natura…
Liquid chromatographic determination of aliphatic amines in water using solid support assisted derivatization with 9-fluorenylmethyl chloroformate
2002
A simple and sensitive method has been developed for the liquid chromatographic determination of short-chain aliphatic amines in water. Analytes are retained in solid-phase extraction (SPE) cartridges, and then derivatized by drawing an aliquot of the fluorogeneic reagent 9-fluorenylmethyl chloroformate (FMOC) through the cartridges. After a certain reaction time the derivatives formed are desorbed with acetonitrile. The collected extracts are then chromatographed on a LiChrospher 100 RP18 125 mm×4 mm i.d., 5 μm, column using an acetonitrile-water gradient. The influence of experimental conditions (SPE material, volume of sample, concentration of FMOC, time of reaction and pH) has been inve…
Chromatographic analysis of phenethylamine-antihistamine combinations using C8, C18 or cyano columns and micellar sodium dodecyl sulfate-pentanol mix…
2001
The chromatographic behaviour of binary and ternary mixtures of several phenethylamines (phenylephrine, phenylpropanolamine, ephedrine, pseudoephedrine and methoxyphenamine) and antihistamines (pheniramine, carbinoxamine, doxylamine, chlorpheniramine, dexchlorpheniramine, dexbrompheniramine, diphenhydramine, tripolidine, azatadine and phenyltoloxamine), found in cough-cold pharmaceutical preparations, was studied using C8, C18 and cyano columns, micellar mobile phases of sodium dodecyl sulfate (SDS) and pentanol and UV detection. Using a C8 column and mobile phases of 0.05 mol l-1 SDS-6% v/v pentanol or 0.15 mol l-1 SDS-2% v/v pentanol at pH 7, more than 30 different phenethylamine-antihist…
Improvement of peak shape and separation performance of beta-blockers in conventional reversed-phase columns using solvent modifiers.
2003
A comparative study of peak shape, elution behavior, and resolution of 16 beta-blockers (acebutolol, alprenolol, atenolol, bisoprolol, carteolol, celiprolol, esmolol, labetalol, metoprolol, nadolol, oxprenolol, pindolol, practolol, propranolol, sotalol, and timolol) chromatographed with hybrid mobile phases of triethylamine (TEA)-acetonitrile and sodium dodecyl sulfate (SDS)-propanol is performed using conventional reversed-phase columns and isocratic elution. Both solvent modifiers (TEA and SDS) prevent the interaction of the basic drugs with the alkyl-bonded phase. However, the protection mechanisms of silanols on the packing are different. Whereas TEA associates with the silanol sites (b…
Micellar-organic versus aqueous-organic mobile phases for the screening of β-blockers
2002
A comparative study of the performance of reversed-phase liquid chromatography with micellar-organic (MLC) and aqueous-organic (RPLC) mobile phases is reported for the separation of 16 -blockers (acebutolol, alprenolol, atenolol, bisoprolol, carteolol, celiprolol, esmolol, labetalol, metoprolol, nadolol, oxprenolol, pindolol, practolol, propranolol, sotalol, and timolol). MLC with hybrid mobile phases of sodium dodecyl sulfate (SDS) and propanol is revealed as a very competitive technique for the screening of these drugs. Using a conventional Spherisorb C18 column, the theoretical plates ( N) and asymmetry factors (B/A) for the optimal mobile phase compositions were in the ranges N = 2200–4…
A microscale Kjeldahl nitrogen determination for environmental waters.
2008
A microscale Kjeldahl system has been designed which has been homemade reduced. The digestor unit of a macroKjeldahl system and a modified glassware microdistillation unit have been used. The optimal conditions for digestion and distillation have been established for ammonium and methylamine as model compound of organic amino nitrogen. The optimised procedure has been applied to the determination of Kjeldahl nitrogen in water samples. Recoveries near 100% and good precision have been achieved. This procedure combines nitrogen miniaturized system and the use of a selective ion electrode for ammonia detection. The analysis time was reduced 4.8 times and the analysis cost 6.6 times compared wi…
Detector supports: application to aliphatic amines in wastewater
2005
Abstract Solid support assisted derivatization coupled to diffuse reflectance spectroscopy (DRS) was proposed and proved useful for the detection and quantification of aliphatic amines in water as an example. Dabsyl chloride (DBS), ninhydrin and sodium 1,2-naphtoquinone 4-sulphonate (NQS) were assayed as derivatization reagents. C 18 and SDB-XC disks and C 18 cartridges were tested for amine retention and after that derivatization. The decrease of the orange colour of dabsyl chloride on SBD-XC disks produced by the formation of its derivative with methylamine in the support (10 min at 100 °C) allowed the selective determination of the amine at concentration level equal or higher than 0.5 mg…
Determination of procaine and tetracaine in plasma samples by micellar liquid chromatography and direct injection of sample
2001
A liquid chromatographic procedure is proposed for the determination of procaine and tetracaine in plasma samples with direct injection. The method uses a Spherisorb octadecylsilane ODS-2 C18 analytical column and a micellar mobile phase containing 0.15 M sodium dodecyl sulphate, 0.5% triethylamine at pH 2.5 and 10% propanol. The UV detection was carried out at 300 nm. Plasma sample preparation required only adequate dilution with the mobile phase before injection into the chromatographic system. The proposed method allows the determination of procaine and tetracaine in plasma at therapeutic levels.