Search results for "facility"
showing 10 items of 139 documents
Spin dependence of {\eta} meson production in proton-proton collisions close to threshold
2018
Taking advantage of the high acceptance and axial symmetry of the WASA-at-COSY detector, and the high degree of the polarized proton beam of COSY, the reaction pp{\to} pp{\eta} has been measured close to threshold to explore the analyzing power Ay. The angular distribution of Ay is determined with the precision improved by more than one order of magnitude with respect to previous results allowing a first accurate comparison with theoretical predictions. The determined analyzing power is consistent with zero for an excess energy of Q = 15 MeV signaling s wave production with no evidence for higher partial waves. At Q = 72 MeV the data reveals strong interference of P s and P p partial waves …
Analytical and Numerical Assessment of Thermally Induced Pressure Waves in the IFMIF-DONES Liquid-Lithium Target
2020
The intended steady-state operation conditions of the International Fusion Materials Irradiation Facility-DEMO Oriented Neutron Source (IFMIF-DONES) target system are based on the D+ beam stationary running at full nominal power (5 MW). Nevertheless, critical situations can occur in the case of unavoidable sudden events like beam trips. The instantaneous variation in the heating power deposited in lithium when the beam is rapidly switched between ON-and OFF-states leads to thermal expansion, which is compensated by the compression of the target material, resulting in locally high pressures and a pressure wave propagating through the target toward the back wall. Besides the tensile stress of…
Experimental program of the Super-FRS Collaboration at FAIR and developments of related instrumentation
2016
The physics program at the super-conducting fragment separator (Super-FRS) at FAIR, being operated in a multiple-stage, high-resolution spectrometer mode, is discussed. The Super-FRS will produce, separate and transport radioactive beams at high energies up to 1.5 AGeV, and it can be also used as a stand-alone experimental device together with ancillary detectors. Various combinations of the magnetic sections of the Super-FRS can be operated in dispersive, achromatic or dispersion-matched spectrometer ion-optical modes, which allow measurements of momentum distributions of secondary-reaction products with high resolution and precision. A number of unique experiments in atomic, nuclear and h…
First tests of the applicability of gamma-ray imaging for background discrimination in time-of-flight neutron capture measurements
2015
In this work we explore for the first time the applicability of using $\gamma$-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr$_3$ scintillating crystal coupled to a position-sensitive photomultiplier and readout through an integrated circuit AMIC2GR. The pinhole collimator is a massive carven block of lead. A series of dedicated measurements with calibrated sources and with a neutron beam incident on a $^{197}$Au sample have been carried out at n_TOF, achieving an enhancement of a factor…
The FRS Ion Catcher
2013
At the FRS Ion Catcher at GSI, projectile and fission fragments are produced at relativistic energies, separated in-flight, range-focused, slowed down and thermalized in a cryogenic stopping cell. A multiple-reflection time-of-flight mass spectrometer (MR-TOF-MS) is used to perform direct mass measurements and to provide an isobarically clean beam for further experiments, such as mass-selected decay spectroscopy. A versatile RF quadrupole transport and diagnostics unit guides the ions from the stopping cell to the MR-TOF-MS, provides differential pumping, ion identification and includes reference ion sources. The FRS Ion Catcher serves as a test facility for the Low-Energy Branch of the Sup…
Conceptual design of the AGATA 1$\pi$ array at GANIL
2017
The Advanced GAmma Tracking Array (AGATA) has been installed at the GANIL facility, Caen-France. This setup exploits the stable and radioactive heavy-ions beams delivered by the cyclotron accelerator complex of GANIL. Additionally, it benefits from a large palette of ancillary detectors and spectrometers to address in-beam γ-ray spectroscopy of exotic nuclei. The set-up has been designed to couple AGATA with a magnetic spectrometer, charged-particle and neutron detectors, scintillators for the detection of high-energy γ rays and other devices such as a plunger to measure nuclear lifetimes. In this paper, the design and the mechanical characteristics of the set-up are described. Based on sim…
The electronion scattering experiment ELISe at the International Facility for Antiproton and Ion Research (FAIR) - A conceptual design study
2011
The electronion scattering experiment ELISe is part of the installations envisaged at the new experimental storage ring at the International Facility for Antiproton and Ion Research (FAIR) in Darmstadt, Germany. It offers an unique opportunity to use electrons as probe in investigations of the structure of exotic nuclei. The conceptual design and the scientific challenges of ELISe are presented. © 2011 Elsevier B.V. All rights reserved.
On the Road to FAIR: 1st Operation of AGATA in PreSPEC at GSI
2013
International audience; The Facility for Antiproton and Ion Research (FAIR), under construction at Darmstadt will provide intense relativistic beams of exotic nuclei at its Superconducting-FRagment Separator. High-resolution in-beam γ-ray spectroscopy will be performed in the HISPEC experiment, using the European Advanced GAmma-ray Tracking Array (AGATA). The PreSPEC-AGATA campaign is the predecessor of HISPEC and runs from 2012 to 2014 at GSI Helmholtzzentrum für Schwerionenforschung GmbH. Up to19 AGATA modules were used at GSI's F Ragment Separator in 2012. We report on the status of the experiment including preliminary results from performance commissioning.
First spatial separation of a heavy ion isomeric beam with a multiple-reflection time-of-flight mass spectrometer
2015
Physics letters / B 744, 137 - 141 (2015). doi:10.1016/j.physletb.2015.03.047
Precision spectroscopy at heavy ion ring accelerator SIS300
2007
Unique spectroscopic possibilities open up if a laser beam interacts with relativistic lithium-like ions stored in the heavy ion ring accelerator SIS300 at the future Facility for Antiproton and Ion Research FAIR in Darmstadt, Germany. At a relativistic factor gamma = 36 the 2P 1/2 level can be excited from the 2S 1/2 ground state for any element with frequency doubled dye-lasers in collinear geometry. Precise transition energy measurements can be performed if the fluorescence photons, boosted in forward direction into the X-ray region, are energetically analyzed with a single crystal monochromator. The hyperfine structure can be investigated at the 2P 1/2 - 2S 1/2 transition for all elemen…