Search results for "fashion.garment"

showing 3 items of 3 documents

Tube Housing Leakiness Radiation and Patient Related Radiation Protective Measures – Gonads Radiation Exposure from Panoramic Radiography

2009

The purpose of this study was to compare patient- and apparatus related radiation protective measures considering gonad radiation exposure at panoramic radiography. The local dose (yGv) in the region of the gonads of a male Alderson-Rando-Phantom was measured by the dosimeter Tol-F (Berthold Technology, Germany) during panoramic radiography (PR) by the digital Orthophos XG plus®(Sirona / Bensheim, Germany). Different radiation protective measures was investigated during constant exposure parameters. In the second part of the survey the same ionisation chamber recorded the scattered radiation at the gonads level of the none protected phantom at various case shielding. Without protection apro…

medicine.medical_specialtyDosimeterbusiness.industryEquivalent doseRadiographyCollimatorRadiationlaw.inventionlawfashionfashion.garmentElectromagnetic shieldingmedicineLead apronRadiologyRadiation protectionbusinessNuclear medicine
researchProduct

Influence of a Commercial Lead Apron on Patient Skin Dose Delivered During Oral and Maxillofacial Examinations under Cone Beam Computed Tomography (C…

2017

The purpose of this paper is to investigate the impact of a commercial lead apron on patient skin dose delivered during maxillofacial CBCT in five critical regions by means of solid-state-dosimetry. Five anatomical regions (thyroid gland, left and right breast, gonads, back of the phantom torso) in an adult female anthropomorphic phantom were selected for dose measurement by means of the highly sensitive solid-state dosimeter QUART didoSVM. Ten repeated single exposures were assessed for each patient body region for a total of five commercial CBCT devices with and without a lead apron present. Shielded and non-shielded exposures were compared under the paired Wilcoxon test, with absolute an…

Malemedicine.medical_specialtyCone beam computed tomographyEpidemiologyHealth Toxicology and MutagenesisCoefficient of variationRadiation DosageImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciencesRadiation Protection0302 clinical medicinefashionSkin Physiological PhenomenaRadiography DentalHumansMedicineRadiology Nuclear Medicine and imagingReproducibilityDosimeterPhantoms Imagingbusiness.industryThyroidAbsorption RadiationEquipment Design030206 dentistryCone-Beam Computed TomographyRadiation ExposureEquipment Failure Analysismedicine.anatomical_structurefashion.garmentLead apronFemaleBody regionRadiologybusinessHealth Physics
researchProduct

Calibration of a thermoluminescent dosimeter worn over lead aprons in fluoroscopy guided procedures

2018

Fluoroscopy guided interventional procedures provide remarkable benefits to patients. However, medical staff working near the scattered radiation field may be exposed to high cumulative equivalent doses, thus requiring shielding devices such as lead aprons and thyroid collars. In this situation, it remains an acceptable practice to derive equivalent doses to the eye lenses or other unprotected soft tissues with a dosimeter placed above these protective devices. Nevertheless, the radiation backscattered by the lead shield differs from that generated during dosimeter calibration with a water phantom. In this study, a passive personal thermoluminescent dosimeter (TLD) was modelled by means of …

Materials scienceeye lens doseTLDImaging phantom030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineOpticsProtective Clothingfashionbackscatter correction factorCalibrationmedicineDosimetryFluoroscopylead apronWaste Management and DisposalDosimetermedicine.diagnostic_testRadiation Dosimetersbusiness.industryEquivalent dosePublic Health Environmental and Occupational HealthEquipment DesignGeneral MedicinefluoroscopyLeadFluoroscopy030220 oncology & carcinogenesisfashion.garmentCalibrationLead apronThermoluminescent DosimetryThermoluminescent dosimeterbusinessJournal of Radiological Protection
researchProduct