Search results for "field tests"

showing 10 items of 36 documents

THE COMPETITIVE DEMANDS OF ELITE MALE RINK HOCKEY

2013

The aim of this study was to simulate the activity pattern of rink hockey by designing a specific skate test (ST) to study the energy expenditure and metabolic responses to this intermittent high-intensity exercise and extrapolate the results from the test to competition. Six rink hockey players performed, in three phases, the 20-metre multi-stage shuttle roller skate test, a tournament match and the ST. Heart rate was monitored in all three phases. Blood lactate, oxygen consumption, ventilation and respiratory exchange ratio were also recorded during the ST. Peak HR was 190.7±7.2 beats · min(-1). There were no differences in peak HR between the three tests. Mean HR was similar between the …

High energyfield testsPhysical Therapy Sports Therapy and RehabilitationAnimal sciencePhysiology (medical)Heart rateenergy expenditureBlood lactateOrthopedics and Sports Medicinerink hockeylcsh:Sports medicineta315Respiratory exchange ratiophysiological responseslcsh:QH301-705.5rink-hockeyOriginal Paperfield testChemistryPhysiological responsesIntermittent exerciseEnergy expenditurelcsh:Biology (General)Breathinglcsh:RC1200-1245Anaerobic exercisehuman activitiesBiology of Sport
researchProduct

Reliability and Intersession Agreement of Microperimetric and Fixation Measurements Obtained with a New Microperimeter in Normal Eyes.

2015

Purpose: To evaluate the reliability and intersession agreement of measurements of retinal sensitivity as well as of the fixation pattern obtained in healthy eyes with a microperimeter integrating the mechanism of the scanning laser ophthalmoscope (SLO) with the static perimetry. Methods: This study included a sample of 44 healthy eyes of 44 subjects of a mean age of 27.0 ± 8.5 years. In all cases, microperimetric exams with the MAIA system (Centervue, Padova, Italy) were performed in three different sessions to evaluate the intersession repeatability. The consistency of measurements was analyzed by using the Friedman test and by analyzing the correlation between consecutive measurements. A…

MAIAAdultMalemedicine.medical_specialtyScanning laser ophthalmoscopeVisual AcuityFixation OcularSensitivity and SpecificityMicroperimetryRetinaMicroperimeterCellular and Molecular NeuroscienceYoung AdultOpticsOphthalmologymedicineHumansMathematicsÓpticabusiness.industryPreferred retinal locusReproducibility of ResultsMean ageRepeatabilityMiddle AgedFixationSensory SystemsHealthy VolunteersOphthalmologyFriedman testFixation (visual)Visual Field TestsFemaleVisual FieldsbusinessMicroperimetryRetinal locusCurrent eye research
researchProduct

Normal Values for Microperimetry with the MAIA Microperimeter: Sensitivity and Fixation Analysis in Healthy Adults and Children

2017

Purpose To establish normative values of retinal sensitivity and parameters describing the fixation pattern using macular analyzer integrity assessment (MAIA) microperimetry (Centervue, Padova, Italy) in adults and children. Methods A sample of 237 eyes of 237 healthy subjects aged between 10 and 70 years (mean age 30.63 ± 16.23 years) was evaluated using the MAIA microperimeter. The following parameters provided by the MAIA device were evaluated: average threshold (AT), macular integrity, fixation indexes (P1% and P2%), bivariate contour ellipse area (BCEA) for 95% and 63% of points, and horizontal (H) and vertical (V) axes of the ellipse of fixation. Differences between different age-rela…

MAIAAdultMalemedicine.medical_specialtyVisual acuityAdolescentVisual AcuityFixation OcularNormal valuesMicroperimetryMicroperimeterYoung Adult03 medical and health sciencesOcular physiology0302 clinical medicineReference ValuesOphthalmologyHumansMedicineRetinal sensitivityMacula LuteaChildÓpticaAgedbusiness.industryReproducibility of ResultsGeneral MedicineMiddle AgedIntegrity assessmentVisual fieldOphthalmologyEye fixationReference valuesFixation (visual)030221 ophthalmology & optometryVisual Field TestsFemaleVisual Fieldsmedicine.symptombusinessMicroperimetry030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

The Evonik-Mainz Eye Care-Study (EMECS): Development of an Expert System for Glaucoma Risk Detection in a Working Population

2015

Purpose To develop an expert system for glaucoma screening in a working population based on a human expert procedure using images of optic nerve head (ONH), visual field (frequency doubling technology, FDT) and intraocular pressure (IOP). Methods 4167 of 13037 (32%) employees between 40 and 65 years of Evonik Industries were screened. An experienced glaucoma expert (JW) assessed papilla parameters and evaluated all individual screening results. His classification into “no glaucoma”, “possible glaucoma” and “probable glaucoma” was defined as “gold standard”. A screening model was developed which was tested versus the gold-standard. This model took into account the assessment of the ONH. Valu…

MaleIntraocular pressureEye Diseasesgenetic structuresOptic disklcsh:MedicineGlaucomacomputer.software_genreNerve Fibers0302 clinical medicineCost of IllnessRisk FactorsAnimal CellsOdds RatioPrevalenceMedicine and Health SciencesMedicine030212 general & internal medicinelcsh:ScienceNeuronsMultidisciplinaryPharmaceuticsApplied MathematicsSimulation and ModelingMiddle AgedVisual fieldPhysical SciencesFemaleAnatomyCellular TypesAlgorithmsResearch ArticleAdultmedicine.medical_specialtyOptic DiskResearch and Analysis MethodsSensitivity and SpecificityDiagnosis DifferentialTonometry Ocular03 medical and health sciencesDrug TherapyOcular SystemOphthalmologyHumansWorking populationIntraocular PressureAgedbusiness.industrylcsh:RBiology and Life SciencesGlaucomaOptic NerveCell BiologyOdds ratioGold standard (test)medicine.diseaseeye diseasesExpert systemOphthalmologyCellular Neuroscience030221 ophthalmology & optometryVisual Field TestsEyesOptometrylcsh:Qsense organsVisual FieldsbusinessHeadcomputerMathematicsNeurosciencePLOS ONE
researchProduct

Kinetic and static perimetry after 16 years and additional OCT-A analysis in eyes with long-lasting optic disc drusen

2021

The aim of the study is to evaluate the progression of visual field (VF) defects over 16 years of observation and to assess abnormalities in vessels and retinal nerve fibre layer (RNFL) thickness in patients with optic disc drusen (ODD). Both static automated perimetry (SAP) and semi-automated kinetic perimetry (SKP) were performed in 16 eyes of 8 patients (mean age 54 years) with ODD among 26 eyes of 13 patients examined 16 years before. The area of I2e, I4e, III4e, and V4e isopters was measured in deg2. The MD and PSD parameters were estimated using SAP. Optical coherence tomography angiography (OCT-A) was additionally performed in 16 ODD eyes and 16 eyes of 8 healthy subjects to estimate…

MaleRetinal Ganglion CellsFovea Centralisgenetic structureschemistry.chemical_compoundNerve FibersAnimal CellsMedicine and Health SciencesMacula LuteaProspective StudiesNeuronsMultidisciplinaryStatistical ModelsOptic Disk DrusenStatisticsQAngiographyRMiddle AgedOptic disc drusenVisual fieldmedicine.anatomical_structurePhysical SciencesOptic nerveMedicineFemaleAnatomyCellular TypesTomography Optical CoherenceOptic discResearch ArticleLong lastingAdultmedicine.medical_specialtyOcular AnatomyScienceOptic DiskVision DisordersOptic DiscYoung AdultOcular SystemOphthalmologymedicineHumansAgedPlexusbusiness.industryFovea centralisBiology and Life SciencesRetinal VesselsRetinalOptic NerveCell Biologymedicine.diseaseeye diseasesCapillariesOphthalmologychemistryCellular NeuroscienceCase-Control StudiesCardiovascular AnatomyEyesBlood VesselsVisual Field Testssense organsVisual FieldsbusinessHeadMathematicsNeuroscience
researchProduct

A two-year follow-up of oral antioxidant supplementation in primary open-angle glaucoma: an open-label, randomized, controlled trial

2014

Purpose To evaluate the effect of oral antioxidant supplementation (OAS) on primary open-angle glaucoma (POAG) over a 2-year follow-up period. Patients and methods In this open-label, randomized controlled trial, 117 eyes of 117 patients with mild or moderate POAG and intraocular pressure under control with topical antiglaucoma medications were recruited and randomly divided into three groups according to supplementation: (1) OAS with (ICAPS R® – Alcon Laboratories, n = 26); (2) OAS without ω-3 fatty acids (OFTAN MACULA® – Laboratorios Esteve, n = 28); and (3) a control group without OAS (n = 63). They all underwent visual field (VF) tests (Humphrey 24-2) and scans using a Fourier-domain op…

MaleRetinal Ganglion CellsIntraocular pressuremedicine.medical_specialtygenetic structuresOpen angle glaucomaVisual AcuityAdministration OralGlaucomaAntioxidantslaw.inventionchemistry.chemical_compoundNerve FibersRandomized controlled triallawOphthalmologyFatty Acids Omega-3medicineHumansProspective StudiesAntihypertensive AgentsIntraocular PressureAgedbusiness.industryRetinalGeneral MedicineMiddle Agedmedicine.diseaseeye diseasesVisual fieldAbsolute deviationOphthalmologychemistryDietary SupplementsVisual Field TestsFemalesense organsVisual FieldsOpen labelbusinessGlaucoma Open-AngleTomography Optical CoherenceFollow-Up StudiesActa Ophthalmologica
researchProduct

Relationship between Psychophysical Measures of Retinal Ganglion Cell Density and In Vivo Measures of Cone Density in Glaucoma.

2017

Purpose Considerable between-individual variation in retinal ganglion cell (RGC) density exists in healthy individuals, making identification of change from normal to glaucoma difficult. In ascertaining local cone-to-RGC density ratios in healthy individuals, we wished to investigate the usefulness of objective cone density estimates as a surrogate of baseline RGC density in glaucoma patients, and thus a more efficient way of identifying early changes. Design Exploratory cohort study. Participants Twenty glaucoma patients (60% women) with a median age of 54 years and mean deviation (MD) in the visual field of –5 dB and 20 healthy controls (70% women) with a median age of 57 years and a mean…

MaleRetinal Ganglion Cellsmedicine.medical_specialtygenetic structuresGlaucomaCell CountCohort Studies03 medical and health scienceschemistry.chemical_compound0302 clinical medicineInterquartile rangeOphthalmologyOptic Nerve DiseasesmedicinePsychophysicsHumansIntraocular PressureReceiver operating characteristicbusiness.industryRetinalMiddle Agedmedicine.diseaseeye diseasesConfidence intervalHealthy VolunteersPeripheralVisual fieldOphthalmologymedicine.anatomical_structurechemistryRetinal ganglion cell030221 ophthalmology & optometryRetinal Cone Photoreceptor CellsVisual Field TestsREFemalesense organsVisual Fieldsbusiness030217 neurology & neurosurgeryGlaucoma Open-AngleTomography Optical CoherenceOphthalmology
researchProduct

Retrograde Maculopathy in Patients With Glaucoma

2017

PURPOSE Macular optical coherence tomography (OCT) analysis can be used for quantitative measures of optic nerve atrophy at a location far from the optic nerve head. This recently led to the finding of microcystic macular edema (MME), that is vacuolar inclusions in the macular inner nuclear layer, in some glaucoma patients. The involvement of individual retinal layers is yet unclear in glaucoma. In this study we systematically investigated glaucoma-induced changes in macular layers to evaluate whether glaucoma-associated damage extends beyond the macular ganglion cell layer. PATIENTS AND METHODS We included 218 consecutive patients and 282 eyes with confirmed primary open-angle glaucoma or …

MaleRetinal Ganglion Cellsmedicine.medical_specialtygenetic structuresOptic DiskVisual AcuityNerve fiber layerGlaucoma610 Medicine & healthExfoliation SyndromeMacular EdemaRetina03 medical and health sciencesNerve Fibers0302 clinical medicineOphthalmologymedicineHumans610 Medicine & healthMacular edemaGanglion cell layerIntraocular PressureAgedRetrospective StudiesAged 80 and overRetinabusiness.industryMiddle Agedmedicine.diseaseeye diseasesOphthalmologyCross-Sectional Studiesmedicine.anatomical_structureInner nuclear layer030221 ophthalmology & optometryOptic nerveVisual Field TestsMaculopathyFemalesense organsbusinessGlaucoma Open-AngleTomography Optical Coherence030217 neurology & neurosurgeryJournal of Glaucoma
researchProduct

Contrast sensitivity loss in the peripheral visual field following laser in situ keratomileusis.

2007

We report a case of contrast sensitivity loss in the peripheral visual field following laser in situ keratomileusis (LASIK). A 50-year-old white man was referred to us for differences in visual perception in the peripheral field between the right eye, which had had LASIK, and the left eye, which was emmetropic. Linear meridional static perimetry was carried out in the 0- to 180-degree meridian using a Goldmann perimeter to assess the peripheral perimetric thresholds. There was a statistically significantly marked increased threshold in contrast sensitivity in the nasal and temporal fields from 40 degrees of eccentricity in the LASIK eye compared with that in the emmetropic eye. Eyes treated…

MaleVisual acuitygenetic structuresEye diseasemedicine.medical_treatmentKeratomileusis Laser In SituVision DisordersVisual AcuityEmmetropiaKeratomileusisContrast SensitivityMedicineHumansmedicine.diagnostic_testbusiness.industryLASIKCorneal TopographyMiddle AgedCorneal topographymedicine.diseaseeye diseasesSensory SystemsVisual fieldOphthalmologyMeridian (perimetry visual field)OptometryVisual Field TestsSurgerysense organsmedicine.symptomVisual FieldsbusinessJournal of cataract and refractive surgery
researchProduct

Sensitivity of the central visual field in 70- to 81-year-old male athletes and in a population sample.

1994

The sensitivity of the central visual field (0°–30°) was studied using an automatic Octopus 500E perimeter in elderly male athletes and in a population sample of men of corresponding age. The athletes (N=96) were endurance and power athletes, who were still active in competitive sports with training histories spanning tens of years. The athletes’ results were compared with those of a sample of men of the same age (70–81 years, N=41) randomly selected from the local population register. The sensitivity values of the athletes, and the endurance athletes in particular, were significantly better than those of the controls, with differences varying from 1 to 2.5 dB in the different areas of the …

Malemedicine.medical_specialtyAgingMultivariate analysisPopulation sampleBackground factorsPerimeterMedicineHumansCentral visual fieldExerciseGeriatric AssessmentAerobic capacityAgedbiologyAthletesbusiness.industrybiology.organism_classificationVisual fieldPhysical therapyPhysical EnduranceVisual Field TestsGeriatrics and GerontologyVisual FieldsbusinessDemographySportsAging (Milan, Italy)
researchProduct