Retrograde nailing versus locking plate osteosynthesis of proximal humeral fractures: a biomechanical study
2011
Background In locking plate osteosynthesis of proximal humeral fractures, secondary varus malalignment is a specific complication. Retron nails (Tantum AG, Neumunster, Germany), among others, have been designed to improve medial support of the calcar humeri. The aim of our biomechanical study was to examine whether Retron nails provide increased stiffness for axial loads and adequate stiffness for torsional loads when compared with Philos plates (Synthes AG, Umkirch, Germany). Materials and methods Twenty-two fresh-frozen paired humeri were collected. After potting the specimens, intact bones were exposed to sinusoidal axial (10-120 N) and torsional (±2.5 Nm) loading for 8 cycles to calcula…
Implant-supported overdenture manufactured using CAD/CAM techniques to achieve horizontal path insertion between the primary and secondary structure:…
2015
This report describes the case of an edentulous patient with an atrophic maxilla and severe class III malocclusion. Prosthetic rehabilitation was performed using CAD/CAM techniques for manufacturing an implant-supported overdenture with horizontal insertion. A vestibulo-lingual insertion overdenture is a precision prosthesis with a fixation system affording a good fit between the primary and secondary structure. Both structures exhibit passive horizontal adjustment. This treatment option requires the same number of implants as implant-supported fixed dentures. The horizontal assembly system prevents the prosthesis from loosening or moving in response to axial and non-axial forces. The techn…
Intramedullary nailing vs. palmar locked plating for unstable dorsally comminuted distal radius fractures: A biomechanical study
2010
Abstract Background The purpose of this study was to compare the stability of a 2.4 mm palmar locking compression plate and a new intramedullary nail-plate-hybrid Targon DR for dorsally comminuted distal radius fractures. Methods An extraarticular 10 mm dorsally open wedge osteotomy was created in 8 pairs of fresh frozen human radii to simulate an AO–A3-fracture. The fractures were stabilized using one of the fixation methods. The specimens were loaded axially with 200 N and dorsal-excentrically with 80 N. 2000 cycles of dynamic loading and axial loading-to-failure were performed. Findings Axial loading revealed that intramedullary osteosynthesis (Targon DR: 369 N/mm) was significantly ( p …
A rare case of peri-implant distal radius fracture☆
2021
A peri-implant fracture near the volar plate of distal radius represent a very rare injury. The main factor of this lesion is high energy trauma on the wrist. We report a case of a 61-year-old woman with a peri-implant fracture located just proximally to the plate and a fracture of the ulnar head that occurred after a simple fall. The patient was surgically treated by plate and screws removal. The fracture was fixed using a longer volar plate for the radial fracture and a plate for the head ulnar fracture. Different factors such as osteoporosis, BMI and screw position could influence the fracture pattern. However, considering growing use of plates for distal radius fracture fixation, the fr…
Bone Augmentation in Dental Implantology Using Press-Fit Bone Cylinders and Twin-Principle Diamond Hollow Drills: A Case Series
2009
Background: Bone transplants are mostly prepared with cutting drills, chisels, and rasps. These techniques are difficult for unexperienced surgeons, and the implant interface is less precise due to unstandardized preparation. Cylindrical bone transplants are a known alternative. Current techniques include fixation methods with osteosynthesis screws or the dental implant. Purpose: A new bone cylinder transplant technique is presented using a twin-drill principle resulting in a customized pressfit of the transplant without fixation devices and combining this with the superior grinding properties of a diamond coating. Materials and Methods: New cylindrical diamond hollow drills are used for cu…
Active-fixation coronary sinus pacing lead extraction: A hybrid approach
2012
Cardiac resynchronization therapy (CRT) can be considered as the standard treatment for patients suffering from heart failure (NYHA III–IV), severely reduced left ventricular (LV) function, and wide QRS complexes. Over the past years, the lead systems used to stimulate the left ventricle have evolved technically from epicardial approaches to a transvenous access accompanied by a significant reduction of procedure-related complication rates [1]. However, even today, LV dislodgement rates ranging 5–10% and the instability of thresholds over time remain the greatest challenges with transvenous LV leads in CRT. Therefore, a special LV lead utilizing active fixation (the Attain StarFix® active f…
Non-metallic implant for patellar fracture fixation: A systematic review
2016
Abstract Introduction Despite good clinical outcome proposals, there has been relatively little published regarding the use of non-metallic implant for patellar fracture fixation. The purpose of the study was to perform a systematic literature review to summarize and evaluate the clinical studies that described techniques for treating patella fractures using non-metallic implants. Methods A comprehensive literature search was systematically performed to evaluate all studies included in the literature until November 2015. The following search terms were used: patellar fracture, patella suture, patella absorbable, patella screw, patella cerclage. Two investigators independently reviewed all a…
Microarchitecture of the Normal Gut Seen with Conventional Histology and Endomicroscopy
2007
For ex vivo histological examination of the gastrointestinal tract, fractions of an organ or small pieces of tissue are needed. Several steps are used in the fixation, staining, and mounting process to ensure production of good-quality histology on glass slides. The most frequently used stain in routine histology is the haematoxylin and eosin (H&E) stain. The most frequently used tissue-staining methods are shown in ⊡ Table 6.1. The final histopathological diagnosis is always based on examination of the whole sample and the structure and architecture of that sample. In cytology, single cells and nuclei are used for making a diagnosis, so staining procedures in cytology are much faster and e…
Mitotic figure counts are significantly overestimated in resection specimens of invasive breast carcinomas.
2013
Several authors have demonstrated an increased number of mitotic figures in breast cancer resection specimen when compared with biopsy material. This has been ascribed to a sampling artifact where biopsies are (i) either too small to allow formal mitotic figure counting or (ii) not necessarily taken form the proliferating tumor periphery. Herein, we propose a different explanation for this phenomenon. Biopsy and resection material of 52 invasive ductal carcinomas was studied. We counted mitotic figures in 10 representative high power fields and quantified MIB-1 immunohistochemistry by visual estimation, counting and image analysis. We found that mitotic figures were elevated by more than th…
Untersuchungen zur Hepatitis B-Antigen(HBAg)-Fixation an peripheren Lymphocyten und isolierten Leberzellen bei Patienten mit entz�ndlichen Lebererkra…
1975
Bei 127 Patienten mit verschiedenen entzundlichen Lebererkrankungen wurde die Fixation von HBAg an peripheren Lymphocyten untersucht. Bei 60 von diesen Patienten wurden im Parallelansatz die Fixation von HBAg an peripheren Lymphocyten und isolierten Leberzellen sowie die Fixation von IgG an isolierten Leberzellen gepruft.