Search results for "flow rate"
showing 10 items of 166 documents
Influence of the pressure head sequence on the soil hydraulic conductivity determined with tension infiltrometer
2005
An increasing and a decreasing sequence of pressure head, h0, values were applied with the tension infiltrometer (TI) to determine the corresponding hydraulic conductivity, K0. The pressure head sequence is expected to influence the K0 results given the hysteretic nature of the hydraulic conductivity relationship. The objective of this study was to evaluate the influence of the selected pressure head sequence on the hydraulic conductivity of a sandy loam soil measured by a multipotential TI experiment. Twenty experiments were carried out by applying h0 values varying between -150 and +5 mm (site A). The h0 values ranged from -150 to -10 mm in another 20 spots (site B). Both wetting and dryi…
Comparative study of modelling the thermal efficiency of a novel straight through evacuated tube collector with MLR, SVR, BP and RBF methods
2021
Abstract Data-based methods are useful for accurate modelling of solar thermal systems. In this work, several artificial neural network (ANN) techniques are proposed to predict the thermal performance of an all-glass straight through evacuated tube solar collector. These are compared to support vector regression analysis. Extensive experimental data sets were collected for training the ANN models. Solar radiation intensity, ambient temperature, wind speed, mass flow rate and collector inlet temperature were selected as the input layer to predict the thermal efficiency of the solar collector. The prediction precision of the ANN models was compared to the multiple linear regression and suppor…
Analyses of the TRACE V5 capability for the simulation of natural circulation and primary/containment coupling in BDBA condition typical of the MASLWR
2014
In the short term period the use of advanced Small Modular Reactor (SMR) is one of the most promising options for the deployment of nuclear technology. The validation and assessment of the best estimate thermal hydraulic system code TRACE against SMR thermal hydraulic phenomena is a novel effort. In this framework the use of the natural circulation database developed at the OSU-MASLWR test facility, simulating the MASLWR reactor prototype, is of interest for analyses of the TRACE code capability in predicting natural circulation and primary/containment coupled behavior in SMR. The target of this paper is to analyze the TRACE V5 capability for the simulation of natural circulation phenomena,…
Draining and drying process development of the Tokamak Cooling Water System of ITER
2016
Abstract The ITER Organization (IO) developed a thermal-hydraulic (TH) model of the complex first wall and blanket (FW/BLK) cooling channels to determine gas flow rate and pressure required to effectively blow out the water in the FW/BLK. In addition, US ITER conducted experiments for selected geometries of FW/BLK flow channels to predict the blowout parameters. The analysis indicates that as low as 2 MPa of pressure difference over the blanket modules will ensure substantial evacuation of the water in blankets with just a few percent remaining in the blanket flow channels. A limited validation study indicates that the analysis yields less conservative results to compare against data collec…
Study of the column efficiency using gradient elution based on Van Deemter plots.
2018
Performance of chromatographic columns is of major importance in the development of more efficient separation methods. So far, a common practice is to study the column behavior in isocratic elution by modifying the flow rate and fitting the theoretical plate height values versus the mobile phase linear velocity, according to the Van Deemter equation. In this work, an approach is presented to extend the measurement of efficiency to linear gradient elution, where the mean retention factor is kept constant at each assayed flow. This avoids a possible source of uncertainty due to the change in the distribution equilibria profile, and makes the mean interactions with the stationary phase in grad…
Prediction of Peak Shape and Characterization of Column Performance in Liquid Chromatography as a Function of Flow Rate
2015
Traditionally, column performance in liquid chromatography has been studied using information from the elution of probe compounds at different flow rates through van Deemter plots, which relate the column plate height to the linear mobile phase velocity. A more recent approach to characterize columns is the representation of the peak widths (or the right and left peak half-widths) for a set of compounds versus their retention times, which, for isocratic elution, give rise to almost linear plots. In previous work, these plots have been shown to facilitate the prediction of peak profiles (width and asymmetry) with optimization purposes. In this work, a detailed study on the dependence of the …
A discrete-element model for viscoelastic deformation and fracture of glacial ice
2015
a b s t r a c t A discrete-element model was developed to study the behavior of viscoelastic materials that are allowed to fracture. Applicable to many materials, the main objective of this analysis was to develop a model specifically for ice dynamics. A realistic model of glacial ice must include elasticity, brittle fracture and slow viscous deformations. Here the model is described in detail and tested with several benchmark simulations. The model was used to simulate various ice-specific applications with resulting flow rates that were compatible with Glen's law, and produced under fragmentation fragment-size distributions that agreed with the known analytical and experimental results.
Apparent and Real Distribution in GPC (Experiments with PMMA Samples)
1971
Abstract Molecular weight distribution curves obtained by GPC are broadened if concentration and flow rate are fixed in the usual range. Therefore, the apparent nonuniformity U app of the samples is larger than the real non-uniformity U = (Mw/Mn) −1. For a number of fractionated and unfractionated samples of polymethyl methacrylate we determined M n and M w by osmotic, light-scattering, and viscosity measurements. Thus, the real value of U can be compared to U app obtained by GPC at different concentrations and flow rates, υ. The excess nonuniformity U exc is evaluated as function of concentration c, polydispersity, molecular weight, and flow rate. For c = 0 and υ = 0, U exc is not far from…
Correlations for estimating the specific capital cost of multi-effect distillation plants considering the main design trends and operating conditions
2018
Abstract This work proposes a correlation for the specific capital cost of multi-effect distillation (MED) plants, considering their main design options and parameters, such as the number of effects, size/capacity, and heat source temperature. These parameters are varied within a large range to cover as many different cases as possible. The cost correlation decouples the evaporator cost and includes in the expression the ratio of the heat exchanger area to a reference one. This area is calculated using a validated MED numerical model, with the results then processed to produce fitted expressions. Two versions of this correlation with different levels of complexity are proposed, which provid…
Some insights on the description of gradient elution in reversed-phase liquid chromatography
2014
The so-called "fundamental equation for gradient elution" has been used for modeling the retention in gradient elution. In this approach, the instantaneous retention factor (k) is expressed as a function of the change in the modifier content (φ(ts )), ts being the time the solute has spent in the stationary phase. This approach can only be applied at constant flow rate and with gradients where the elution strength depends on the column length following a f(t-l/u) function, u being the linear mobile phase flow rate, and l the distance from the column inlet to the location where the solute is at time t measured from the beginning of the gradient. These limitations can be solved by using the h…