Search results for "flu"
showing 10 items of 16583 documents
Enhancement of the Multipactor Threshold Inside Nonrectangular Iris
2018
Multipactor breakdown is studied inside the capacitive iris of a rectangular waveguide with a skewed slot along its longitudinal cross section. Both the iris length and height are assumed to be small compared to the electromagnetic wavelength. Therefore, the quasi-static approximation is applied so as to describe the RF field distribution inside the iris gap, whereas a 2-D model is used to analyze the electron motion. The peculiarities of RF field structure are studied using the conformal mapping approach, which shows that the electric field lines can be approximated by circular arcs when the iris length is much larger than its height. The electron motion inside the iris gap is analyzed usi…
Radiofrequency and 2.45 GHz electron cyclotron resonance H−volume production ion sources
2016
The volume production of negative hydrogen ions () in plasma ion sources is based on dissociative electron attachment (DEA) to rovibrationally excited hydrogen molecules (H2), which is a two-step process requiring both, hot electrons for ionization, and vibrational excitation of the H2 and cold electrons for the formation through DEA. Traditionally ion sources relying on the volume production have been tandem-type arc discharge sources equipped with biased filament cathodes sustaining the plasma by thermionic electron emission and with a magnetic filter separating the main discharge from the formation volume. The main motivation to develop ion sources based on radiofrequency (RF) or electro…
Multimode time-dependent gyrotron equations for different time scales
2017
The work of H.K. was supported by the European Regional Development Funding of the Project No. 1.1.1.1/ 16/A/004.
H− extraction systems for CERN’s Linac4 H− ion source
2018
Abstract Linac4 is a 160 MeV linear H − accelerator at CERN. It is an essential part of the beam luminosity upgrade of the Large Hadron Collider (LHC) and will be the primary injector into the chain of circular accelerators. It aims at increasing the beam brightness by a factor of 2, when compared to the currently used 50 MeV linear proton accelerator, Linac2. Linac4’s ion source is a cesiated RF-plasma H − ion source. Several beam extraction systems were designed for H − beams of 45 keV energy, 50 mA intensity and an electron to H − ratio smaller than 5. The goal was to extract a beam with an rms-emittance of 0 . 25 π mm mrad. One of the main challenges in designing an H − extraction…
The effect of plasma electrode collar structure on the performance of the JYFL 14GHz electron cyclotron resonance ion source
2013
Abstract The influence of a so-called collar structure on the performance of the JYFL 14 GHz electron cyclotron resonance ion source (ECRIS) has been studied experimentally at the Department of Physics, University of Jyvaskyla (JYFL). The collar is a cylindrical structure extruding inwards from the plasma electrode. The collar length was varied between 5 and 60 mm. For some ion species a moderate performance improvement was achieved in terms of extracted beam current and transverse emittance up to 30 mm collar length. Longer collars resulted in a substantial performance decrease. Different collar materials, i.e. nonmagnetic stainless steel, aluminum and Al 2 O 3 , and a wide range of ion sp…
Estimation of Photon Flux of the Oxygen Lyman-alpha Line Emitted from the W7-X Plasmas
2020
The low-Z impurities of the magnetic confined fusion plasmas can provide important information about the wall condition and plasma–wall interactions. In order to accomplish this aim, a special spectrometer called “C/O Monitor” was designed for the W7-X experiment. This system is dedicated to measure Lyman-α transitions of four low-Z impurities: carbon (3.4 nm), oxygen (1.9 nm), nitrogen (2.5 nm) and boron (4.9 nm). It is a high throughput and high time resolution spectrometer which allows to measure the line intensities evolution of indicated elements including information of the background (continuum). The designed spectrometer consists of two vacuum chambers positioned nearly horizontally…
System for control of polarization state of light and generation of light with continuously rotating linear polarization
2019
We present a technique for generating light in an arbitrary polarization state. The technique is based on interference of two orthogonally polarized light beams, whose amplitudes and phases are controlled with a Mach-Zehnder inteferometer with acousto-optic modulators (AOMs) placed in each arm. We demonstrate that via control over amplitudes, phases, and frequencies of acoustic waves driving the AOMs, any polarization state can be synthesized. In particular, we demonstrate generation of linearly polarized light, whose polarization plane continuously rotates at a rate from 1 kHz to 1 MHz. Such light finds applications in science (e.g., investigations of Bloch-Siegert effect) and technology (…
Time resolved measurements of hydrogen ion energy distributions in a pulsed 2.45 GHz microwave plasma
2017
A plasma diagnostic study of the Ion Energy Distribution Functions (IEDFs) of H+, H+2H2+, and H+3H3+ ions in a 2.45 GHz hydrogen plasma reactor called TIPS is presented. The measurements are conducted by using a Plasma Ion Mass Spectrometer with an energy sector and a quadrupole detector from HIDEN Analytical Limited in order to select an ion species and to measure its energy distribution. The reactor is operated in the pulsed mode at 100 Hz with a duty cycle of 10% (1 ms pulse width). The IEDFs of H+, H+2H2+, and H+3H3+ are obtained each 5 μs with 1 μs time resolution throughout the entire pulse. The temporal evolution of the plasma potential and ion temperature of H+ is derived from the d…
Measurements of the energy distribution of electrons lost from the minimum B-field -- the effect of instabilities and two-frequency heating
2020
Further progress in the development of ECR ion sources (ECRIS) requires deeper understanding of the underlying physics. One of the topics that remains obscure, though being crucial for the performance of the ECRIS, is the electron energy distribution (EED). A well-developed technique of measuring the EED of electrons escaping axially from the magnetically confined plasma of an ECRIS was used for the study of EED in unstable mode of plasma confinement, i.e. in the presence of kinetic instabilities. The experimental data were recorded for pulsed and CW discharges with a room-temperature 14 GHz ECRIS at the JYFL accelerator laboratory. The measurements were focused on observing differences bet…
Towards quantum phase slip based standard of electric current
2019
An accurate standard of electric current is a long-standing challenge of modern metrology. It has been predicted that a superconducting nanowire in the regime of quantum fluctuations can be considered as the dynamic equivalent of a chain of conventional Josephson junctions. In full analogy with the quantum standard of electric voltage based on the Josephson effect, the quantum phase slip phenomenon in ultrathin superconducting nanowires could be used for building the quantum standard of electric current. This work presents advances toward this ultimate goal.