Search results for "fluoroscopy"
showing 10 items of 54 documents
Spiral-CT zum Nachweis von Koronararterienverkalkungen und Vorhersage einer koronaren Herzerkrankung - Vergleich zur Durchleuchtung und Koronarangiog…
1997
PURPOSE Evaluation of clinical relevance of coronary calcifications detected by helical CT. Evaluation of congruence with fluoroscopy (FS) and coronary angiography. Comparison with studies reporting on application of ultrafast computed tomography. MATERIALS AND METHODS 40 patients underwent helical CT (2 mm slice thickness, table-feed 3 mm/s). Coronary angiography and FS were performed in usual technique. Stenosis and calcifications were evaluated semiquantitatively. RESULTS 28 of 28 stenoses > or = 75% were detected via helical CT by evaluation of calcification (FS: 19). One non-detected solitary stenosis was calculated as 40%. FS did not detect 4 cases with 2-vessel and 3-vessel disease e…
Quantitative Analysis of Real-Time Infrared Thermography for the Assessment of Lumbar Sympathetic Blocks: A Preliminary Study
2021
Lumbar sympathetic blocks (LSBs) are commonly performed to treat pain ailments in the lower limbs. LSBs involve injecting local anesthetic around the nerves. The injection is guided by fluoroscopy which is sometimes considered to be insufficiently accurate. The main aim was to analyze the plantar foot skin temperature data acquired while performing LSBs in patients with complex regional pain syndrome (CRPS) affecting the lower limbs. Forty-four LSBs for treating lower limb CRPS in 13 patients were assessed. Pain medicine physicians visualized the infrared thermography (IRT) video in real time and classified the performance depending on the observed thermal changes within the first 4 min. Th…
Gold vs. platinum-iridium tip catheter for cavotricuspid isthmus ablation: the AURUM 8 study
2010
Aims Gold electrodes have the theoretical advantage of creating bigger lesions than platinum–iridium (Pt–Ir) electrodes. We performed a prospective randomized study to compare the clinical efficacy of standard 8 mm Pt–Ir tip catheter (control) and 8 mm gold-tip catheters in the ablation of the cavotricuspid isthmus (CTI)-dependent atrial flutter. Methods and results A total of 463 patients undergoing CTI ablation in 19 clinical centres were randomized to receive the treatment by gold-tip or control catheter. The primary endpoint was cumulative radiofrequency (RF) application duration until achieving bidirectional CTI block. It did not differ significantly for the two catheters. The gold-tip…
Extraction of Entrapped Capsules from the Small Bowel by Means of Push-and-Pull Enteroscopy with the Double-Balloon Technique
2005
The new technique of push-and-pull enteroscopy using the double-balloon technique (double-balloon enteroscopy) makes it possible to remove swallowed foreign bodies causing intestinal obstruction deep in the small bowel without the need for surgical laparotomy. This report describes two cases of enteroscopic removal of entrapped capsules. In one patient with acute recurrent intestinal bleeding and recurrent abdominal pain, Crohn's disease had been suspected on capsule endoscopy. The second patient, with known Crohn's disease, was suffering from abdominal pain and underwent capsule endoscopy for investigation of the small bowel. Prior enteroclysis had not revealed stenoses in either patient. …
Transnasal endoscopy for direct visual control of esophageal stent placement without fluoroscopy
2012
Placement of self-expanding metal stents (SEMSs) is a well-established treatment for esophageal stenosis and postoperative anastomotic leaks. Conventional endoscopic procedures for SEMS placement require fluoroscopic guidance, but transnasal endoscopy (TNE) with ultraslim endoscopes may allow precise stent release under direct visual control without the need for fluoroscopy. This prospectively collected data investigated the feasibility and safety of TNE-guided SEMS placement without fluoroscopy. Between March 2009 and February 2011, 20 consecutive patients underwent TNE-guided SEMS placement without fluoroscopy. The technical success rate was 100 % and no fluoroscopy was required during th…
Revision Rate of Misplaced Pedicle Screws of the Thoracolumbar Spine-Comparison of Three-Dimensional Fluoroscopy Navigation with Freehand Placement: …
2017
BACKGROUND Recent studies have shown higher accuracy rates of image-guided pedicle screw placement compared to freehand (FH) placement. However, data focusing on the impact of spinal navigation on the rate of revision surgeries caused by misplaced pedicle screws (PS) are scarce. OBJECTIVE This study is aimed at identifying the rate of revision surgeries for misplaced PS comparing three-dimensional (3D) fluoroscopy navigation (3DFL) with FH PS placement. METHODS A retrospective analysis was conducted of 2232 patients (mean age, 65.3 ± 13.5 years) with 13,703 implanted PS who underwent instrumentation of the thoracolumbar spine between 2007 and 2015. Group 1 received surgery with use of 3DFL …
Sialodochoplasty in the treatment of salivary-duct stricture in chronic sialoadenitis: technique and results
2007
PURPOSE: This study was undertaken to investigate peroral balloon angioplasty of salivary-duct strictures (sialodochoplasty) in chronic sialadenitis, analysing the technique, results and limitations. MATERIALS AND METHODS: Nine patients underwent sialodochoplasty: seven for Stensen''s-duct strictures and two for Wharton''s-duct strictures. One patient had a double stricture of Stensen''s duct and another a salivary stone associated with a Wharton''s-duct stricture. All patients were subjected to preliminary sialography to evaluate stricture site, length and grade. Sialodochoplasty was performed after local anaesthesia and progressive dilation of the salivary-duct orifice. RESULTS: The stric…
Peroperative Intravascular Ultrasound for Endovascular Aneurysm Repair versus Peroperative Angiography: A Pilot Study in Fit Patients with Favorable …
2020
The aim of this study was to compare intravascular ultrasound (IVUS) assistance for endovascular aortic aneurysm repair (EVAR) to standard assistance by angiography.From June 2015 to June 2017, 173 consecutive patients underwent EVAR. In this group, 69 procedures were IVUS-assisted with X-ray exposure limited to completion angiography for safety purposes because an IVUS probe does not yet incorporate a duplex probe (group A), and 104 were angiography-assisted procedures (group B). All IVUS-assisted procedures were performed by vascular surgeons with basic duplex ultrasound (DUS) training. The primary study endpoints were mean radiation dose, duration of fluoroscopy, amount of contrast media…
Single-centre experience and preliminary Results of intravascular ultrasound in endovascular aneurysm repair
2019
Background Intravascular ultrasound (IVUS) has been introduced as diagnostic adjunct to provide new insights into the diagnosis and therapy of vascular disease. Herein, we compared the outcomes of conventional endovascular aneurysm repair (EVAR) and EVAR with IVUS in patients presenting with infrarenal abdominal aortic aneurysm using a propensity-matched cohort. Methods From May 2013 to August 2017, 221 patients were retrospectively analyzed. Of that, 122 patients were eligible for inclusion and underwent propensity score matching. Perioperative mortality and morbidity, renal function impairment, endoleak incidence, mean contrast medium usage, operative time, radiation exposure (including f…
CT-guided nephrostomy–An expedient tool for complex clinical scenarios
2018
Abstract Introduction & objectives Percutaneous nephrostomy [ 1 ] has emerged as a pivotal approach in the therapeutic management of the obstructed urinary tract. A consecutive incorporation of ultrasonic and radiographic guidance, the approach experienced an almost ubiquitious distribution while most centers currently applying either one or both of these tools jointly. However, success of ultrasound-guidance is limited in obese patients and non-dilated uropathy. In turn, fluoroscopy usually requires an opacification of the urinary collecting system by intravenous or antegrade contrast media injection, which might be harmful for already impaired renal function, raise intrapelvic pressure an…