Search results for "four"
showing 10 items of 1678 documents
A comparison among different techniques for human ERG signals processing and classification
2014
A comparison among different techniques for human ERG signals processing and classification ( Articles not published yet, but available online Article in press About articles in press (opens in a new window) ) Barraco, R.a, Persano Adorno, D.a , Brai, M.a, Tranchina, L.b a Dipartimento di Fisica e Chimica, Università di Palermo and CNISM, Viale delle Scienze, Ed. 18, I-90128 Palermo, Italy b Laboratorio di Fisica e Tecnologie Relative - UniNetLab, Università di Palermo, Viale delle Scienze, Ed. 18, I-90128 Palermo, Italy Abstract Feature detection in biomedical signals is crucial for deepening our knowledge about the involved physiological processes. To achieve this aim, many analytic appro…
Wooden panel paintings investigation: An air-coupled ultrasonic imaging approach
2007
In this paper, a method for the study of wooden panel paintings using air-coupled acoustical imaging is presented. In order to evaluate the advantages of the technique, several samples were made to mimic panel paintings along with their typical defects. These specimens were tested by means of both single-sided and through-transmission techniques using planar transducers. Image data were processed by means of a two-dimensional (2-D)-fast Fourier transform-based algorithm to increase the S/N ratio and 2-D representations (C-scans) were generated. The simulated defects were imaged using both configurations. Investigations were undertaken on four antique paintings from a private collection. The…
Coordination properties of adenosine-5'-monophosphate and related ligands towards Me2Sn(IV)2+ in aqueous solution.
2002
Abstract The coordination of Me 2 Sn(IV) 2+ to adenosine-5′-monophosphate (AMP) and the related compounds d -ribose-5-phosphate (R5P), d -glucose-1-phosphate (G1P) and d -glucose-6-phosphate (G6P) in aqueous solution was investigated by means of potentiometric titration, and 1 H-, 31 P-NMR and Mossbauer spectroscopic methods in the pH range 2–11 ( I =0.1 M NaClO 4 , 298 K). The complex of AMP and Me 2 Sn(IV) 2+ precipitated at low pH was characterised by elemental analysis, FT-IR and Mossbauer spectroscopic methods. From a comparison of the p K values obtained in the presence and absence of metal ion and the stability constants for the different systems, the coordination of {N} is excluded,…
Characterization of NOM
2015
Worldwide reports over the last few decades have shown that the amount of natural organic matter (NOM) in surface water is continuously increasing, which has an adverse effect on drinking water purification. For many practical and hygienic reasons, the presence of NOM in drinking water is undesirable. Various technologies have been proposed for NOM removal with varying degrees of success. The properties and amount of NOM, however, can significantly affect the process efficiency. To improve and optimize these processes, it is essential to characterize and quantify NOM at various points during purification and treatment. It is also important to be able to understand and predict the reactivity…
Intra- and Interhemispheric Electroencephalogram Coherence in Siblings Discordant for Schizophrenia and Healthy Volunteers
1997
Former studies had pointed to an increased electroencephalogram (EEG) coherence in schizophrenics, but it remained unsolved whether this deviation represents the premorbid state or is only a consequence of the current or previous schizophrenic episodes. To clarify this question, we tested the hypothesis that subjects at elevated risk also reveal higher coherences compared to healthy controls. For that, intra- and interhemispheric EEG coherences were investigated in untreated schizophrenics, their healthy siblings, and healthy controls. Differences were only found regarding the intrahemispheric coherences. Both in schizophrenics and, even though to a lesser degree, in their siblings signific…
Trabecular trajectory in the articular processes of the human fourth cervical vertebra
2001
The articular processes (AP) of the neural arch have been implicated in weight transmission through the cervical spine. To analyse the mechanism of weight transmission in the AP, we studied the direction of forces within it, in particular, the pattern of trabecular trajectories. Twenty-two AP from C4 vertebrae were studied in anatomical sections, and corresponding photoelastic models from selected sections were constructed and analysed. Anatomical and photoelastic findings show the subarticular spongiosa of the superior articular process (SAP) to be orthogonally arranged with vertical and oblique trabeculae in the direction of compressive forces and additional trabeculae always oriented per…
Noninvasive double confirmation of cocaine abuse.
2013
A double confirmation procedure, based on the combined application of Ion Mobility Spectrometry (IMS) and Infrared Spectroscopy (IR), has been developed for the noninvasive unambiguous identification of cocaine consume. The use of nasal mucus as a biological specimen for cocaine abuse confirmation has been proposed as an alternative to the use of blood and urine due to its noninvasive character and the presence of the parent compound instead of its metabolites. Sampling conditions, interferences caused by cutting agents and other substances, and limits of identification (LOI) and confirmation (LOC) have been deeply evaluated. The procedure combines the high sensitivity of the IMS to identif…
Understanding the effect of window length and overlap for assessing sEMG in dynamic fatiguing contractions: A non-linear dimensionality reduction and…
2020
The Short-Time Fourier transform (STFT) is a helpful tool to identify muscle fatigue with clinical and sports applications. However, the choice of STFT parameters may affect the estimation of myoelectrical manifestations of fatigue. Here, we determine the effect of window length and overlap selections on the frequency slope and the coefficient of variation from EMG spectrum features in fatiguing contractions. We also determine whether STFT parameters affect the relationship between frequency slopes and task failure. Eighty-eight healthy adult men performed one-leg heel-rise until exhaustion. A factorial design with a window length of 50, 100, 250, 500, and 1000 ms with 0, 25, 50, 75, and 90…
Reproducibility and Daytime-Dependent Changes of Corneal Epithelial Thickness and Whole Corneal Thickness Measured With Fourier Domain Optical Cohere…
2016
To evaluate the reproducibility of Fourier domain anterior segment optical coherence tomography (RTVue) based on repeated measurements of corneal thickness (CT) and epithelial thickness (ET) and to test daytime-dependent changes of these parameters.Twenty-three eyes from 23 healthy volunteers were included in this prospective study. Three clinical observers performed 3 consecutive measurements each of CT and ET in 3 sessions using RTVue, resulting in 9 measurements per session. Session 1 was performed at 9 AM ± 1 hour, session 2 at 4 PM ± 1 hour on the same day, and session 3 at 9 AM ± 1 hour 2 days later. CT and ET were assessed in 9 areas: corneal vertex, 4 paracentral zones, and 4 periph…
Comparing indirect methods of digit ratio (2D:4D) measurement.
2008
The ratio of the lengths of the second and fourth finger (2D:4D) has been proposed to index prenatal exposure to androgens. Different methods have been utilized to measure digit ratio, however, their measurement precision and economy have not been systematically compared yet. Using different indirect methods (plastic ruler, caliper, computer software), three independent raters measured finger lengths of 60 participants. Generally, measurement precision (intraclass correlation coefficient, technical error of measurement, and relative technical error of measurement) was acceptable for each method. However, precision estimates were highest for the computer software, indicating excellent measur…