Optimal frame rate when there were stallion sperm motility evaluations and determinations for kinematic variables using CASA-Mot analysis in differen…

2020

This study was conducted to determine optimum image capture frame rates (FRO) when there was evaluation of different types of counting chambers used for CASA-Mot determinations of stallion sperm motility. Sperm VCL was determined at frame rates of 25-250 f/s in: 1) Spermtrack® (Spk) 10 and 20 chambers (drop displacement-type chambers 10 and 20 μm-deep respectively; and 2) ISAS®D4C10, ISAS®D4C20 (10 and 20 μm-deep respectively) and ISAS®D4C20 L (20 μm-deep) capillary loaded chambers. Values for different sperm kinematic variables were determined using each chamber at 250 f/s, which is the maximum frame rate that the software can be used for analyses. With evaluation of Spk chambers, there wa…

MaleAnalytical chemistryBeat (acoustics)Kinematics03 medical and health sciences0302 clinical medicineEndocrinologyFood AnimalsImage Processing Computer-AssistedAnimalsHorsesSperm motilityMathematics030219 obstetrics & reproductive medicineSperm Count0402 animal and dairy science04 agricultural and veterinary sciencesGeneral MedicineFrame rateImage capture040201 dairy & animal scienceSpermBiomechanical PhenomenaSemen AnalysisAmplitudeSperm MotilityAnimal Science and ZoologySoftwareAnimal reproduction science
researchProduct

CASA-Mot technology: how results are affected by the frame rate and counting chamber.

2017

For over 30 years, CASA-Mot technology has been used for kinematic analysis of sperm motility in different mammalian species, but insufficient attention has been paid to the technical limitations of commercial computer-aided sperm analysis (CASA) systems. Counting chamber type and frame rate are two of the most important aspects to be taken into account. Counting chambers can be disposable or reusable, with different depths. In human semen analysis, reusable chambers with a depth of 10 µm are the most frequently used, whereas for most farm animal species it is more common to use disposable chambers with a depth of 20 µm . The frame rate was previously limited by the hardware, although chang…

MaleImage processingKinematicsReproductive technologyBiology03 medical and health sciences0302 clinical medicineEndocrinologySpecies SpecificityGeneticsImage Processing Computer-AssistedOptimal combinationAnimalsHumansAnimal speciesMolecular Biology030219 obstetrics & reproductive medicineSperm Count0402 animal and dairy science04 agricultural and veterinary sciencesFrame rate040201 dairy & animal scienceSpermatozoaSemen AnalysisReproductive MedicineSperm MotilityAnimal Science and ZoologyBiological systemSoftwareDevelopmental BiologyBiotechnologyReproduction, fertility, and development
researchProduct

Effect of frame rate capture frequency on sperm kinematic parameters and subpopulation structure definition in boars, analysed with a CASA-Mot system.

2018

Motility is the most widely used indicator of sperm quality. Computer-Assisted Semen Analysis (CASA) allows the objective evaluation of sperm motility parameters. CASA technology is a common tool to predict semen doses in farm animal reproduction. The kinds of video cameras used until now for image acquisition have presented limited frame rates (FR), which have a negative influence on the quality of the obtained data. The aim of the present work was to define the optimal frame rate for a correct evaluation of boar sperm motility and its subpopulation structure. Eighteen ejaculates from nine mature boars of the Pietrain breed were used. Using the ISAS® v1 CASA-Mot system, with a video camera…

MaleSwineSemenKinematicsSemen analysis03 medical and health sciences0302 clinical medicineEndocrinologySemenStatisticsmedicineAnimalsBoar spermSperm motilityMathematics030219 obstetrics & reproductive medicinemedicine.diagnostic_test0402 animal and dairy science04 agricultural and veterinary sciencesFrame rate040201 dairy & animal scienceSpermSpermatozoaBiomechanical PhenomenaSemen AnalysisPrincipal component analysisSperm MotilityAnimal Science and ZoologySoftwareBiotechnologyReproduction in domestic animals = Zuchthygiene
researchProduct

Combined effects of type and depth of counting chamber, and rateof image frame capture, on bull sperm motility and kinematics

2019

Semen quality assessment requires accurate, reliable and objective methods for examination of sperm variables including sperm motility. For preparation of semen samples for artificial insemination, as a genetic resource, samples that are used for insemination need to have the capacity to result in a highly acceptable fertility rate. Several methods have been developed for evaluation of bull sperm in laboratory conditions and for preparation of doses for artificial insemination. Computer-assisted semen analyses can provide objective information on various sperm variables. Nevertheless, this equipment requires fine-calibrations considering differences among species, breeds and conditions for …

Maleendocrine systemmedicine.medical_treatmentSemenKinematicsBreedingBiologyInseminationSperm kinematics03 medical and health sciencesSemen quality0302 clinical medicineEndocrinologyFood AnimalsStatisticsBull breedImage Processing Computer-AssistedmedicineAnimalsInsemination ArtificialSperm motility030219 obstetrics & reproductive medicineSperm Counturogenital systemArtificial insemination0402 animal and dairy science04 agricultural and veterinary sciencesGeneral MedicineSpermatozoa040201 dairy & animal scienceSpermBreedBiomechanical PhenomenaSemen AnalysisCattleAnimal Science and ZoologyCASA-MotCapture frame rateCounting chamber
researchProduct

Two-photon high-speed light-sheet volumetric imaging of brain activity during sleep in zebrafish larvae

2020

Although it is well known that zebrafish display the behavioural signature of sleep, the neuronal correlates of this state are not yet completely understood, due to the complexity of the measurements required. For example, when performed with visible excitation light, functional imaging can disrupt the day/night cycle due to the induced visual stimulation. To address this issue, we developed a custom-made two-photon light-sheet microscope optimized for high-speed volumetric imaging. By employing infra-red light (not visible to the larva) for excitation, we are able to record wholebrain neuronal activity with high temporal- and spatial-resolution without affecting the sleep state. In two-pho…

Materials scienceMicroscopebusiness.industry02 engineering and technology021001 nanoscience & nanotechnologyFrame rate01 natural sciencesIntensity (physics)law.invention010309 opticsOpticsCalcium imagingCardinal pointTwo-photon excitation microscopylaw0103 physical sciencesMicroscopyPremovement neuronal activityTwo-photon light sheet0210 nano-technologybusiness
researchProduct

RGB imaging system for mapping and monitoring of hemoglobin distribution in skin

2011

A prototype R-G-B imaging system for mapping of skin hemoglobin distribution has been designed and tested. Device basically consists of a commercial RGB sensor (CMOS, max. frame rate 87 fps for VGA resolution), RGB LED ringlight illuminator and orthogonally orientated polarizers for reducing specular reflectance. The system was examined for monitoring of hemoglobin concentration changes during specific provocations - arterial/venous occlusions and heat test. Hemoglobin distribution maps of several skin malformations were obtained, as well.

Materials scienceVideo Graphics Arraybusiness.industryPolarizerFrame rateReflectivitylaw.inventionOpticslawRGB color modelComputer visionHemoglobinSpecular reflectionArtificial intelligencebusinessSPIE Proceedings
researchProduct

A microscope configuration for nanometer 3-D movement monitoring accuracy.

2011

In this paper we present a new microscopy configuration based upon temporal tracking of a secondary reflected speckle by imaging the speckle through properly defocused optics. The configuration is used to monitor three-dimensional (3-D) spontaneous contraction of rat cardiac muscle cells while achieving nanometer tracking accuracy at a rate of 30 frames per second (fps) without using interferometric recording. Estimation of the change in the optical path of accuracy of 50 nm in the transverse direction and of 200 nm in the axial direction was achieved.

MicroscopyMicroscopeMaterials sciencebusiness.industryFourier opticsGeneral Physics and AstronomyCell BiologyTracking (particle physics)Frame ratelaw.inventionRatsSpeckle patternInterferometryOpticsOptical pathImaging Three-DimensionalStructural BiologylawMicroscopyAnimalsGeneral Materials ScienceMyocytes CardiacbusinessCells CulturedMicron (Oxford, England : 1993)
researchProduct

Single-shot digital holography
by use of the fractional Talbot effect

2009

We present a method for recording in-line single-shot digital holograms based on the fractional Talbot effect. In our system, an image sensor records the interference between the light field scattered by the object and a properly codified parallel reference beam. A simple binary two-dimensional periodic grating is used to codify the reference beam generating a periodic three-step phase distribution over the sensor plane by fractional Talbot effect. This provides a method to perform single-shot phase-shifting interferometry at frame rates only limited by the sensor capabilities. Our technique is well adapted for dynamic wavefront sensing applications. Images of the object are digitally recon…

Optics and PhotonicsHolographyHolographyPhysics::Opticslaw.inventionImaging Three-DimensionalOpticslawImage Processing Computer-AssistedTalbot effectComputer SimulationImage sensorWavefrontPhysicsbusiness.industryLasersTalbot effectReproducibility of ResultsEquipment DesignFrame rateAtomic and Molecular Physics and OpticsInterferometryInterferometryReference beamImagebusinessDigital holographyOptics Express
researchProduct

Single-shot two-frame π-shifted spatially multiplexed interference phase microscopy

2019

Single-shot, two-frame, π-shifted spatially multiplexed interference microscopy (π-SMIM) is presented as an improvement to previous SMIM implementations, introducing a versatile, robust, fast, and accurate method for cumbersome, noisy, and low-contrast phase object analysis. The proposed π-SMIM equips a commercially available nonholographic microscope with a high-speed (video frame rate) enhanced quantitative phase imaging (QPI) capability by properly placing a beam-splitter in the microscope embodiment to simultaneously (in a single shot) record two holograms mutually phase shifted by π radians at the expense of reducing the field of view. Upon subsequent subtractive superimposition of hol…

PaperMaleMicroscopequantitative phase imagingBiomedical EngineeringHolographyPhase (waves)Holographydigital holographic microscopyfringe analysis01 natural scienceslaw.inventionImaging010309 opticsBiomaterialsOpticsInterference (communication)lawCell Line Tumor0103 physical sciencesImage Processing Computer-AssistedHumansMicroscopy InterferencePhysicsphase retrievalbusiness.industryProstatic NeoplasmsFrame rateAtomic and Molecular Physics and OpticsInterference microscopyElectronic Optical and Magnetic Materialsinterference microscopyDigital holographic microscopyPhase retrievalbusinessAlgorithmsJournal of Biomedical Optics
researchProduct

2017

Micro-fluidic pumps as well as artificial micro-swimmers are conveniently realized exploiting phoretic solvent flows based on local gradients of temperature, electrolyte concentration or pH. We here present a facile micro-photometric method for monitoring pH gradients and demonstrate its performance and scope on different experimental situations including an electro-osmotic pump and modular micro-swimmers assembled from ion exchange resin beads and polystyrene colloids. In combination with the present microscope and DSLR camera our method offers a 2 \mu m spatial resolution at video frame rate over a field of view of 3920x2602 \mu m^2. Under optimal conditions we achieve a pH-resolution of …

PhysicsMicroscopebusiness.industryMicrofluidicsGeneral Physics and AstronomyField of view02 engineering and technologyElectrolyteModular design010402 general chemistry021001 nanoscience & nanotechnologyFrame rate01 natural sciences0104 chemical scienceslaw.inventionCharacterization (materials science)law0210 nano-technologyBiological systembusinessImage resolutionNew Journal of Physics
researchProduct