Search results for "frequ"
showing 10 items of 2272 documents
Combined Analysis of OFDM-UWB Transmission in Hybrid Wireless-Optical Access Networks
2009
[EN] The hybrid wireless-optical transmission of ultra-wideband signals employing orthogonal frequency-division multiplexing modulation (OFDM) ultra-wideband (UWB) as defined in the ECMA-368 standard is experimentally analyzed in this letter. The OFDM-UWB signals provide 400 Mb/s per user at optical distances from 5 to 50 km on standard single-mode fiber (SSMF). The analysis includes the wireless radiation from 0 to 3 m after optical transmission. The results indicate a maximum error-vector-magnitude degradation of 2.5 dB measured at 1.5-m radio after 50-km SSMF optical transmission for the first two UWB channels. This degradation translates to 1-m maximum wireless-reach penalty.
Experimental characterization of bodycentric passive RFID systems
2011
Recent progresses in the design of wearable RFID tag antennas stimulate the idea of passive bodycentric systems wherein the required power to drive the wearable tags is directly scavenged from the interrogation signal emitted by the reader unit. While active bodycentric links have been extensively investigated, the feasibility of passive systems is still questionable due to the poor sensitivity of the tags and to the modest read distances. This paper describes an articulated measurement campaign with textile wearable low-profile tags in the UHF RFID band. It is demonstrated that both on-body and off-body links are feasible with a power budget fully compliant with the available technology. T…
Cascaded PD-PI controller for active power frequency control of two-area multi-units power system
2016
In interconnected multi-area power system; the real power generation within each area has to be managed through active power frequency control considering scheduled power exchange. In this work, two different controllers, namely cascaded PD-PI and conventional PID controller are considered for analyzing the dynamic response of the two area interconnected power system. Area-1 consists of two reheat type thermal generating power plant units and area-2 comprises of two non-reheat type thermal power plant units. The controller gains of PD-PI and PID controllers are efficiently tuned by ‘Teaching Learning based Optimization Technique’. In area-1, 1% step load disturbance is applied for analyzing…
Comparative evaluation of pulse width modulation techniques on effective DC link voltage utilization of grid connected inverter
2016
In this paper, comparison between two different Pulse Width Modulation (PWM) techniques employed for three phase voltage source inverter (VSI) is discussed. The three phase voltage source inverter is basic topology used to supply a grid. In this paper we have design a LC filter between the inverter and the grid in order to stabilize the output voltage. The filter gives sinusoidal three phase voltage at the output of the inverter with almost zero/less harmonic distortion. A suitable PWM technique is employed to obtain the required output voltage in the line side of the inverter. The PWM generation techniques used mainly based on sinusoidal based Pulse Width Modulation (SPWM) and Space Vector…
An FPGA-Based Software Defined Radio Platform for the 2.4GHz ISM Band
2006
A prototype of a Software Defined Radio (SDR) platform has been successfully designed and tested implementing a reconfigurable IEEE 802.11 and ZigBee receiver. The system exploits the reconfiguration capability of an FPGA for implementing a number of receiver configurations that share the same RF front-end. Configurations can be switched at run time, or can share the available logic and radio resource.
Optimizing the MAC Protocol in Localization Systems Based on IEEE 802.15.4 Networks
2017
Radio frequency signals are commonly used in the development of indoor localization systems. The infrastructure of these systems includes some beacons placed at known positions that exchange radio packets with users to be located. When the system is implemented using wireless sensor networks, the wireless transceivers integrated in the network motes are usually based on the IEEE 802.15.4 standard. But, the CSMA-CA, which is the basis for the medium access protocols in this category of communication systems, is not suitable when several users want to exchange bursts of radio packets with the same beacon to acquire the radio signal strength indicator (RSSI) values needed in the location proce…
Design of a configurable multispectral imaging system based on an AOTF.
2011
In this paper, we present a configurable multispectral imaging system based on an acousto-optic tunable filter (AOTF). Typically, AOTFs are used to filter a single wavelength at a time, but thanks to the use of a versatile sweeping frequency generator implemented with a direct digital synthesizer, the imager may capture a configurable spectral range. Experimental results show a good spectral and imaging response of the system for spectral bandwidth up to a 50 nm.
Review on photovoltaic based active generator
2015
An active generator has the capacity to support frequency control and instantaneous power balance. The grid operator adjusts the power dispatch of generators according to power demand fluctuations. Photovoltaic (PV) based active generators can be used as load following generators in the same manner as other power dispatch generators. This new type of distribution system, based on active generator(s), needs new innovative management and operation strategies for increasing the penetration of intermittent renewable energy systems. The considered PV based active generator has three units, i.e., PV array, battery storage and super capacitor. In this review paper, the management and operation app…
Low stiffness variation in structural systems: identification and localization
2008
When a very low damage occurs, the undamaged structural response totally overlaps the damaged one either in time domain or in frequency domain; on the other hand, by considering some characteristics of the analytical signal, such as the phase, it has been possible to develop a damage identification procedure that allows the identification and localization of damage even if the structure experiences multiple damages at the same time. This procedure is also robust with respect to the presence of measuring noise. In order to assess the validity of the proposed damage identification procedure, numerical applications on single degree of freedom and 2 DOF and 4 DOF are presented using data record…
A parametric study on unbalanced three phase islanded microgrids with inverter interfaced units
2013
In this paper, the solution of the power flow for unbalanced three phase microgrids systems is proposed. The study aims at the integration of inverter interfaced units using the control law used for primary voltage and frequency regulation, so as to take into account possible small variations of these parameters to account for sudden load changes. The proposed study deals with unbalanced systems which is the typical case of small distribution systems and shows how the power losses term varies as the regulators parameters vary as well, thus showing that these are sensitive parameters that could have an important role in optimal management of such systems.