Search results for "germani"
showing 10 items of 488 documents
NTD-GE-based microcalorimeter performance
2000
Our group has been developing x-ray microcalorimeters consisting of neutron transmutation doped (NTD) germanium thermistors attached to superconducting tin absorbers. We discuss the performance of single pixel x-ray detectors, and describe an array technology. In this paper we describe the read-out circuit that allows us to measure fast signals in our detectors as this will be important in understanding the primary cause of resolution broadening. We describe briefly a multiplexing scheme that allows a number of different calorimeters to be read out using a single JFET. We list the possible causes of broadening and give a description of the experiment which best demonstrates the cause of the…
Probing double beta decay by nuclear muon capture
2005
A reliable theoretical calculations on two-neutrino and neutrinoless double-beta-decay rates requires a solid description about the nuclear structure of the intermediate nuclear states. It has been suggested that the ordinary muon capture could be used to probe the structure of the intermediate states in double beta decays.
Performance of a gamma-ray tracking array: Characterizing the AGATA array using a 60Co source
2017
International audience; The AGATA (Advanced GAmma Tracking Array) tracking detector is being designed to far surpass the performance of the previous generation, Compton-suppressed arrays. In this paper, a characterization of AGATA is provided based on data from the second GSI campaign. Emphasis is placed on the proper corrections required to extract the absolute photopeak efficiency and peak-to-total ratio. The performance after tracking is extracted and GEANT4 simulations are used both to understand the results and to scale the measurements up to predicted values for the full 4π implementation of the device.
Experimental investigation of the 02+ band in Sm154 as a β-vibrational band
2014
Abstract A study of Sm 154 through γ -ray and internal conversion electron coincidence measurements was performed using the Silicon And GErmanium spectrometer (SAGE). An upper limit for the ρ 2 ( E 0 ; 2 2 + → 2 1 + ) and measurement of the ρ 2 ( E 0 ; 4 2 + → 4 1 + ) monopole transitions strengths were determined. The extracted transition strength for each is significantly lower than that predicted by either the Bohr and Mottelson β -vibration description or the interacting boson model. Hence, the long standing interpretation of these states as a collective band built on the 0 2 + state, which is conventionally assigned as a Bohr and Mottelson β vibration is questionable.
A dedicated decay-spectroscopy station for the collinear resonance ionization experiment at ISOLDE
2013
A newdecay-spectroscopystation(DSS)has been developed to be coupled to the collinear resonance ionization spectroscopy (CRIS) beam line at CERN-ISOLDE. The system uses a rotatable wheel with ten 20 mg=cm2 carbon foils as beam implantation sites for the efficient measurement of charged decay products. Silicon detectors are placed on either side of the carbon foil in an optimal geometry to cover a large solid angle for detecting these charged particles. In addition to the silicon detectors at the on-beam axis position, a second pair of off-beam axis detectors are placed at the wheel position 108 deg. away, allowing longer-lived species to be studied. Up to three high purity germanium detector…
Implantation-decay station for low-energy proton measurements
2013
Abstract We have built an implantation-decay station for β - delayed proton and α decay studies at the focal plane of the Momentum Achromat Recoil Spectrometer (MARS) at the Cyclotron Institute of Texas A&M University. Energetic secondary beams with a small momentum spread are stopped in a controlled manner into a very thin silicon strip detector. In addition, high-purity germanium detectors are installed for γ ray detection. Here we give a description of the setup and the observed performance down to E p ≈ 200 keV using implanted 23 Al and 31 Cl sources.
Resolution, efficiency and stability of HPGe detector operating in a magnetic field at various gamma-ray energies
2008
Abstract The use of High Purity Germanium detectors (HPGe) has been planned in some future experiments of hadronic physics. The crystals will be located close to large spectrometers where the magnetic fringing field will not be negligible and their performances might change. Moreover high precision is required in these experiments. The contribution of magnetic field presence and long term measurements is unique. In this paper the results of systematic measurements of the resolution, stability and efficiency of a crystal operating inside a magnetic field of 0.8 T, using radioactive sources in the energy range from 0.08 to 1.33 MeV, are reported. The measurements have been repeated during sev…
Probing structural changes in the very neutron-deficient Os isotopes with recoil-decay tagging
2005
In recent years, the exploitation of the iecoil-decay tagging (RDT) technique with,large arrays of germanium detectors has revealed much information about the structure of heavy nuclei approaching the proton drip line. The yrast bands of the N <= 93 osmium isotopes have been identified in a campaign of tagging experiments using various spectrometer arrays coupled to the RITU gas-filled separator based at the University of Jyvaskyla. Trends in the yrast state excitation energies have indicated a transition from gamma-soft triaxial to near-spherical shapes with decreasing neutron number. Recent experimental results for Os-162 obtained with the JUROGAM and GREAT spectrometers also indicate the…
Imaging test setup for the coded-mask /spl gamma/-ray spectrometer SPI
2001
The European Space Agency's International Gamma-Ray Astrophysics Laboratory (INTEGRAL) will be launched in 2002. One of its two main instruments is the spectrometer SPI. It uses 19 HPGe detectors to observe the sky in the energy range of 20 keV to 8 MeV with a resolution of /spl Delta/E/E/spl ap/0.2%. Directional information is obtained using a coded mask. The expected angular resolution is about 20, The SPI imaging test setup (SPITS) was built at the Max-Planck-Institut fur Extraterrestische Physik, Germany, to allow experimental verification of the imaging properties of SPI. SPITS consists of a coded hexagonal uniformly redundant array (HURA) mask and two germanium detectors. The mask is …
Study of background characteristics of a low-level HPGe spectrometer with passive shielding in various configurations
1997
Abstract A low-background germanium spectrometer has been investigated with different combinations of shielding materials in two locations at ground level. In particular, seven shielding configurations have been tested in a room with thick walls and ceiling. The background components, peaks and continuum in the 50–2600 keV energy region, obtained in the several experimental conditions are reported and discussed.