Search results for "harmonic analysis"

showing 10 items of 75 documents

A self-synchronizing instrument for harmonic sources detection in power systems

2004

The deregulation of energy markets holds out new prospects for contract between customers and utilities, in which the price of energy can depend on voltage quality and load characteristics, as well as on the responsibility for disturbances caused to supply voltage in power systems. In this context, harmonic sources detection is one of the main problems, because of equipment sensibility and the proliferation of loads which absorb non-sinusoidal currents. In this paper the authors present a new instrument based on a time domain method for the detection of harmonic active powers in three-phase systems, which can be usefully applied even in the presence of unbalance or asymmetry. The amplitude …

Total harmonic distortionEngineeringComputer sciencebusiness.industryPhase angleElectrical engineeringSynchronizingContext (language use)AC powerElectric power systemAmplitudeQuality (physics)DistortionHarmonicElectronic engineeringTime domainElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheInstrumentationHarmonic analysis harmonic distortion phase locked loops (PLLs) power measurement power quality power system harmonics power system measurementsVoltage
researchProduct

Polluting loads detection in power systems: a decision-making strategy based on nonactive power measurements

2010

In this paper a novel decision-making strategy is proposed for the detection of polluting loads in three-phase power systems. It makes use of simple indices, which are expressed as a function of some nonactive power quantities, previously proposed by the authors and derived from the approach of the IEEE Std. 1459–2000. The decision-making rules for the proposed strategy are presented and discussed, by means of some simulation tests.

Total harmonic distortionEngineeringbusiness.industryControl engineeringFunction (mathematics)AC powerPower (physics)power measurement harmonic distortion power definitions IEEE Std. 1459-2000 harmonic sourcesHarmonic analysisElectric power systemPower system simulationbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

A novel approach based on nonactive powers for the identification of disturbing loads in power systems

2007

In this paper, a new approach is proposed for the detection of harmonic sources in polluted power systems. It is a single- point strategy, based on a comparison among different "nonactive" power quantities proposed in literature that, in the same working conditions, assume different values at the same metering section. Some simulations tests were carried out on a standard IEEE test system proposed by other authors as a benchmark system for the analysis of multipoint measurement techniques for harmonic pollution monitoring. The obtained results show that the proposed single-point approach is in agreement with other strategies already proposed in the literature and can provide useful indicati…

Total harmonic distortionEngineeringbusiness.industryEnergy Engineering and Power TechnologyAC powerDetection of harmonic sources harmonic distortion power quality power system harmonics reactive powerPower (physics)Harmonic analysisElectric power systemPower system simulationHarmonicElectronic engineeringMetering modeElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

A time domain strategy for the measurement of IEEE Standard 1459-2000 power quantities in nonsinusoidal three-phase and single-phase systems

2008

This paper describes a time domain technique for the detection of fundamental and harmonic components of voltages and currents, which is able to evaluate all the quantities required by IEEE standard 1459-2000. The technique does not require any spectral analysis to separate the fundamental positive-sequence components from harmonic, negative-sequence and zero-sequence ones. In the paper the development of the proposed technique is presented for three-phase systems, both three-wires and four-wires, as well as for single-phase systems. The implementation of the proposed technique on a PC-based instrument is also described and experimental results are presented. Finally, accuracy specification…

Total harmonic distortionEngineeringbusiness.industryEnergy Engineering and Power TechnologyHarmonic distortion IEEE Standard 1459-2000 phase-locked loops (PLLs) power measurement power quality.Power (physics)Harmonic analysisPhase-locked loopThree-phasePersonal computerHarmonicElectronic engineeringTime domainElectrical and Electronic EngineeringbusinessSettore ING-INF/07 - Misure Elettriche E Elettroniche
researchProduct

Theoretical and Experimental Comparison of Total Harmonic Distortion Factors for the Evaluation of Harmonic and Interharmonic Pollution of Grid-Conne…

2006

Grid connected photovoltaic systems are increasingly used in electrical distribution systems. However, they inject distorted currents. Therefore special attention must be paid to harmonic and interharmonic measurements. The new edition of IEC 61000-4-7 introduces the concept of harmonic and interharmonic groups, which implies new expressions for Total Harmonic Distortion factors. In the paper a theoretical and experimental comparison is made between the different total harmonic distortion factors in order to show which of the currently defined distortion factors is best-suited to detect harmonic and interharmonic pollution. Experimental tests were carried out first by means of a calibrator …

Total harmonic distortionEngineeringbusiness.industryPhotovoltaic systemElectrical engineeringEnergy Engineering and Power TechnologyGridlaw.inventionHarmonic analysislawElectrical networkDistortionPersonal computerElectronic engineeringHarmonicElectrical and Electronic EngineeringbusinessGrid-connected photovoltaic systems harmonic and interharmonic analysis IEC 61000-4-7 Ed 2002.IEEE Transactions on Power Delivery
researchProduct

An enhanced approach based on IEEE 1459 for the detection of disturbing loads in distorted and unbalanced three-phase power systems

2009

This paper presents an enhanced approach for the detection of disturbing loads in distorted and/or unbalanced three-phase power systems in both cases of three and four-wires. It is based on the IEEE Std. 1459-2000 effective apparent power resolution and it requires only the separation of the fundamental components of voltage and current from the remaining harmonic content. In the paper, the formulation of the novel approach is given and some simulation results are presented.

Total harmonic distortionEngineeringbusiness.industryharmonic distortion power definitions power quality harmonic sourcesAC powerHarmonic analysisElectric power systemPower system simulationThree-phaseElectronic engineeringHarmonicbusinessSettore ING-INF/07 - Misure Elettriche E ElettronicheVoltage
researchProduct

Improved Switching Strategy for Selective Harmonic Elimination in DC-AC Signal Generation via Pulse-Width Modulation

2013

Published version of an article in the journal: Abstract and Applied Analysis. Also available from the publisher at: http://dx.doi.org/10.1155/2013/870904 Open Access We present an advanced design methodology for pulse-width-modulated (PWM) DC-AC signal generation. Using design methods based on the Walsh transform, AC sinusoidal signals can be approximated by suitable PWM signals. For different AC amplitudes, the switching instants of the PWM signals can be efficiently computed by using appropriate systems of explicit linear equations. However, the equation systems provided by conventional implementations of this approach are typically only valid for a restricted interval of AC amplitudes a…

Total harmonic distortionOptimization problemArticle Subjectlcsh:MathematicsApplied Mathematics:Enginyeria electrònica [Àrees temàtiques de la UPC]Anàlisi harmònicaInterval (mathematics)lcsh:QA1-939VDP::Mathematics and natural science: 400::Mathematics: 410::Analysis: 411SignalElectric current convertersHarmonic analysisAmplitudeHadamard transformControl theoryConvertidors de corrent elèctricWalsh Funcions deWalsh functionsAnalysisPulse-width modulationLinear equationMathematicsAbstract and Applied Analysis
researchProduct

High Order Harmonic Passive Mode-Locking In Double-Clad Fiber Laser

2009

We report passive mode-locking of a soliton erbium-doped double-clad fiber laser operating at the 322nd harmonic of the fundamental cavity frequency. Repetition rates scalable up to 3 GHz have been obtained with a pulse duration of about 1 ps and a pulse energy of about 18 pJ. The supermode suppression at the 322nd harmonic is better than 25 dB. The dynamics of emergence of this operating regime is also presented revealing a very long timescale.

[PHYS.PHYS.PHYS-OPTICS] Physics [physics]/Physics [physics]/Optics [physics.optics][PHYS.PHYS.PHYS-OPTICS]Physics [physics]/Physics [physics]/Optics [physics.optics]Materials science[ PHYS.PHYS.PHYS-OPTICS ] Physics [physics]/Physics [physics]/Optics [physics.optics]business.industryPhysics::OpticsPulse durationSoliton (optics)02 engineering and technologyLaser01 natural scienceslaw.invention010309 opticsHarmonic analysis020210 optoelectronics & photonicsOpticsDouble-clad fiberMode-lockinglawFiber laser0103 physical sciences0202 electrical engineering electronic engineering information engineeringHarmonicbusinessComputingMilieux_MISCELLANEOUS
researchProduct

Rungen lause ja sovelluksia inversio-ongelmiin

2018

funktioteoriamatka-aikatomografiakuvantaminenRungen lauseharmonic analysismatemaattiset mallitCalderónin ongelmaharmoninen analyysidifferentiaaliyhtälötGel’fandin ongelmainversio-ongelmat
researchProduct

IEEE Std. 1459 power quantities ratio approaches for simplified harmonic emissions assessment

2018

The paper investigates the suitability of using power ratio parameters for harmonic emissions assessment at the point of common coupling (PCC). The study is carried out starting from the IEEE Std. 1459-2010 apparent power decomposition, where power factors are defined for evaluating line utilization and harmonic pollution levels. In addition, the study investigates the behavior of new parameters, which are expressed in terms of ratio between IEEE Std. 1459-2010 power quantities. The study is carried out for both single-phase and three-phase case, also considering the presence of capacitors. ? 2018 IEEE.

harmonic sources; IEEE Std. 1459-2010; power definitions; power measurement; power quality020209 energy02 engineering and technologyAC powerAutomotive engineeringlaw.inventionPower (physics)harmonic distortionHarmonic analysisCapacitorHarmonic pollutionlawPower ratio0202 electrical engineering electronic engineering information engineeringHarmonicPoint of common couplingPower measurement harmonic distortion power definitions power quality IEEE Std. 1459-2010 harmonic sourcesSettore ING-INF/07 - Misure Elettriche E ElettronicheMathematics2018 18th International Conference on Harmonics and Quality of Power (ICHQP)
researchProduct