Search results for "harmonic distortion"
showing 10 items of 67 documents
A low cost and easy re-configurable instrument for power quality survey
2004
In this document the development of a low cost and user friendly PC-based instrument for power quality measurement is proposed, according to IEC 61000-4-7 and standard IEC 61000-4-30. It is an easily re-configurable instrument able to measure harmonics, interharmonics and amplitude disturbances and supply unbalance. In order to verify its accuracy, the instrument has been tested according standard test procedures, by means of a built-up calibration test bench.
On the methodologies for the calibration of static electricity meters in the presence of harmonic distortion
2010
This paper is focused on the problems related to the calibration of static electricity meters with nonsinusoidal test waveforms. This is an up-to-date issue since the harmonic distortion levels are ever increasing, especially in low-voltage power systems, and in such conditions the performances of the modern static electricity meters can be negatively affected, depending on the implemented measurement algorithm. Thus it is important to test the meters with nonsinusoidal waveforms. The paper analyzes the problems related to both the choice of the test signals to be used for calibration and the implemented metric, with a particular focus on the reactive energy meters. The analysis is supporte…
Measurement Uncertainty of Harmonic Emission Indicators based on IEEE Std. 1459-2010
2020
The study presented in this paper is aimed at analyzing the measurement uncertainty impact on the evaluation of some power ratio parameters for harmonic emissions assessment based on IEEE Std. 1459-2010 apparent power decomposition. In addition to power factors for line utilization and harmonic pollution levels evaluation defined in the Standard, the study covers also some new parameters, which have been introduced by the authors as IEEE Std. 1459-2010 power quantities ratios. The measurement of the aforesaid parameters is implemented on a PC-based wattmeter, in order to investigate the measurement uncertainty impact on the evaluation of the power ratios. The obtained results show that, in …
Recursive Selective Harmonic Elimination for Multilevel Inverters: Mathematical Formulation and Experimental Validation
2023
A recursive method that eliminates +1 harmonics and their respective multiples from the output voltage of a cascaded H-bridge multilevel inverters with = 2 dc sources ( = 1, 2, 3,...) is proposed. It solves 2×2 linear systems with not singular matrices and always gives an exact solution with very low computational effort. Simulated results in three-phase five, nine, seventeen and thirty three level CHB inverters, and experimental results in five-level inverter demonstrate the validity of the method.
Characterization of Current Transformers in the Presence of Harmonic Distortion
2008
The CTs performance under distorted conditions are usually characterized by means of the frequency response test. In this paper a new way to characterize CTs, closer to real operative conditions, is proposed. The harmonic phase angle and ratio errors are measured when the CTs are excited with a nonsinusoidal current composed of a fundamental and one harmonic, with adjustable phase shift. The errors measured using the new approach were found larger than the ones obtained with the frequency response. This suggests that frequency response is not a reliable method to evaluate the CT performance under distorted conditions.
Characterization and Error Compensation of a Rogowski Coil in the Presence of Harmonics
2011
This paper reports the results of an experimental study dealing with a commercial Rogowski coil current transducer (RCCT) in the presence of harmonic distortion. The RCCT was observed under two conditions: 1) sinusoidal excitation with frequencies from 50 to 750 Hz and 2) nonsinusoidal excitation using fundamental frequency and one harmonic, with adjustable amplitude and phase shift. The experimental results show only a weak dependence of the harmonic current ratio error and phase displacement on the amplitude and phase shift of the excitation harmonic. The phase displacement is also independent of the conductor position within the Rogowski coil window. An error compensation method, based o…
Performances of a three-phase five-level cascaded H-bridge inverter with phase shifted B-spline based modulation techniques
2017
This paper presents a novel study of the performances of a five-level three-phase Cascaded H-Bridge Multilevel Inverter with Phase Shifted B-Spline based modulation techniques. The study has been focused on the use of B-Spline functions as carrier signals in order to evaluate the performances of the converter in terms of harmonic content on the output voltage. In the first step of this analysis the THD% has been taken into account to compare the voltage waveforms. Interesting results have been found on the fundamental amplitude of the phase and line voltage. Moreover, harmonic spectra has been compared to evaluate the different harmonic distribution in the voltage waveforms. In this work th…
Harmonic reduction in CHB 13-level inverters by PAM fundamental-frequency strategy
2019
In this paper cascaded H-bridges (CHB) 13-level inverters are considered and a particular pulse amplitude modulation (PAM) strategy is introduced to mitigate or eliminate many harmonic components on the output voltage, in order to obtain low Total Harmonic Distortion (THD) factor. This procedure defines different dc voltage sources and sets of six switching angles, depending on an integer parameter $q$ belonging to the close interval $I=[11, 15]$ . The obtained THD doesn't depend on modulation index $m$ . The control of $m$ is made by changing the dc voltage sources that depend linearly on m, while the switching angles remain constant. An investigation about the role of the $q$ parameter on…
A single-point approach based on IEEE 1459-2000 for the identification of prevailing harmonic sources detection in distorted three phase power systems
2009
This paper deals with a novel single-point strategy for the detection of prevailing harmonic sources downstream or upstream the metering section in three-phase power systems. It is an enhancement of a previous strategy, already developed by the authors and it is based on the comparison of three non-active power quantities which are based on the IEEE Std. 1459-2000 approach. The method does not require any spectral analysis of voltages and currents because it is based only on the separation of the fundamental components from the harmonic content of voltage and current. In the paper, the effectiveness of the strategy is investigated by means of simulation tests which were carried out on a IEE…
A reexamination of voltage distortion for classical carrier-based vs B-Spline modulation of three-phase Voltage Sources Inverters
2015
Voltage waveform improvement has been the object of several investigations for many years and a manifold of different solutions have been proposed to reduce the harmonic content in Voltage Source Inverters (VSI) power application. In many cases this improvements have been obtained by modifying the reference voltage modulating signal. The recent introduction of cardinal B-spline functions, used as carrier signals, has given rise to a new modulation technique whose main characteristic is a lower value of the Total Harmonic Distortion (THD). After the discussion on the B-Spline modulation principle and on its computational effort, a performance comparisons is carried out by means of Total Harm…