Search results for "healthy"
showing 10 items of 824 documents
Effects of baseline fitness and BMI levels on changes in physical fitness during military service.
2019
Objectives The purpose of the present study was to investigate how aerobic fitness, muscle fitness and body mass index (BMI) change in relation to their baseline levels during 6-12 months of military service. Design Retrospective longitudinal follow-up study. Methods The study group consisted of 249 279 healthy young male conscripts (age 19.1 ± 0.4 yrs.) who completed their military service between the years 2005-2015. Anthropometrics (body mass, height, BMI), aerobic fitness (12-minute running test) and muscle fitness (sit-ups, push-ups, standing long jump) were measured. Results A 12-minute running test improved by 5% (107 ± 292 m), standing long jump 1% (2.1 ± 16.2 cm), 1-min sit-ups 19%…
Standing up from a chair as a dynamic equilibrium task: a comparison between young and elderly subjects.
2000
The purpose of this study was to analyze and compare the features of center of mass (CoM) control along anterior/posterior axis in young and elderly subjects during sit-to-stand (STS). From a sitting position, seven healthy young subjects and seven healthy elderly subjects were asked to stand up from a chair under different experimental conditions (visual conditions: normal and blindfolded; speed: normal and as fast as possible). Analysis of results was based upon the concept of a “dynamic equilibrium area” (DEA), which in turn identified the dynamic limits of balance. The results showed that both the maximal CoM velocity in the horizontal axis and the CoM velocity at the instant of seat-of…
Influence of age and sex on aortic distensibility assessed by MRI in healthy subjects
2010
International audience; Abstract: Magnetic resonance imaging (MRI) is particularly well adapted to the evaluation of aortic distensibility. The calculation of this parameter, based on the change in vessel cross-sectional area per unit change in blood pressure, requires precise delineation of the aortic wall on a series of cine-MR images. Firstly, the study consisted in validating a new automatic method to assess aortic elasticity. Secondly, aortic distensibility was studied for the ascending and descending thoracic aortas in 26 healthy subjects. Two homogeneous groups were available to evaluate the influence of sex and age (with an age limit value of 35 years). The automatic postprocessing …
Noninvasive Determination of Anaerobic Threshold Based on the Heart Rate Deflection Point in Water Cycling
2015
This study compared heart rate (HR), oxygen uptake (V[Combining Dot Above]O2), percentage of maximal HR (%HRmax), percentage of maximal V[Combining Dot Above]O2, and cadence (Cad) related to the anaerobic threshold (AT) during a water cycling maximal test between heart rate deflection point (HRDP) and ventilatory (VT) methods. In addition, the correlations between both methods were assessed for all variables. The test was performed by 27 men in a cycle ergometer in an aquatic environment. The protocol started at a Cad of 100 b·min-1 for 3 minutes with subsequent increments of 15 b·min-1 every 2 minutes until exhaustion. A paired two-tailed Student's t-test was used to compare the variables …
Corneal Thickness Response after Anesthetic Eye Drops: Our Own Results and Meta-Analysis.
2017
We aimed to test if there are different patterns in the central corneal thickness (CCT) response after instilling oxybuprocaine anesthetic eye drops and also to determine whether there is a significant change in the CCT. CCT was measured in 60 eyes of 60 healthy subjects before and during the hour after oxybuprocaine 0.4% eye drops were instilled. In addition, a systematic review and meta-analysis were carried out in order to answer the following PICO (patient, intervention, comparison, and outcome) question: What effect do anesthetic eye drops have on CCT values? We found no significant changes in the mean CCT values during the hour’s observation (ANOVA, p=0.209), and the meta-analysis rev…
Static posturography with dynamic tests. Usefulness of biomechanical parameters in assessing vestibular patients.
2012
Abstract Introduction and objective Posturography allows us in evaluating postural control. This study showed the posturographic parameters that were useful for assessing the functional ability to maintain balance in our sample of vestibular patients. Material and methods Of a total of 89 patients, 59 were healthy subjects and 30 had a peripheral vestibular disorder. The subjects were studied using the posturographic NedSVE/IBV system, combining static (Romberg) and dynamic (stability limits and rhythmic weight shifts) tests. We then compared the measurements found in the groups. Results Normal subjects showed significantly lower oscillations than our patients in all of the posturographic p…
Two-stage multi-Gaussian fitting of conduit artery photoplethysmography waveform during induced unilateral hemodynamic events.
2014
Photoplethysmography (PPG) is an optical technique with high diagnostic potential, yet clinical applications remain underdeveloped. Standardization of signal recording and quantification of waveform are essential prerequisites for broader clinical use. The aim of this study was to utilize a two-stage multi-Gaussian fitting technique in order to examine the parameters of conduit artery PPG waveform recorded during increasing the unilateral regional vascular resistance (RVR). This study was conducted on 14 young and healthy volunteers; various external compressions (ECs) were performed by inflating a tight cuff at 0, 40, 80, and 200 mmHg, while registering femoral PPG (wavelength 880 nm), dia…
An Eighteen-Minute Submaximal Exercise Test to Assess Cardiac Fitness in Response to Aerobic Training
2018
Romagnoli, M, Alis, R, Sanchis-Gomar, F, Lippi, G, and Arduini, A. An 18-minute submaximal exercise test to assess cardiac fitness in response to aerobic training. J Strength Cond Res 32(10): 2846-2852, 2018-We aimed to evaluate the utility of a submaximal heart rate recovery (HRR) test to monitor changes in cardiac fitness after aerobic training. Twenty healthy subjects were assigned to a control (n = 10) or a training (n = 10) group. Subjects in the training group performed 8 weeks of bicycle training, followed by 8 weeks of detraining. Heart rate recovery was assessed after exercises at 65% and 80% HRmax. The HRR test was performed at weeks 0 (W0), 4 (W4), 8 (W8), and 16 (W16) in the tra…
Range of Normal Liver Stiffness and Factors Associated With Increased Stiffness Measurements in Apparently Healthy Individuals
2018
Background & Aims: Transient elastography (TE) is a noninvasive technique used to measure liver stiffness to estimate the severity of fibrosis. The range of liver stiffness measurements (LSMs) in healthy individuals is unclear. We performed a systematic review to determine the range of LSMs, examined by TE, in healthy individuals and individuals who are susceptible to fibrosis. Methods: We collected data from 16,082 individuals, in 26 cohorts, identified from systematic searches of Embase, Ovid MEDLINE, Cochrane Central Register of Controlled Trials, and Cochrane Database of Systematic Reviews for studies of liver stiffness measurements. Studies analyzed included apparently healthy adul…
Baseline [18F]-FDOPA kinetics are predictive of haloperidol-induced changes in dopamine turnover and cognitive performance: A positron emission tomog…
2007
The telencephalic dopamine innervations contribute to the modulation of cognitive processing. However, the relationship between cognitive effects of D(2/3)-receptor antagonism and dopamine transmission is not described in healthy subjects. We therefore tested effects of acute haloperidol (5 mg/d over 3 days) on continuous performance task (CPT) performance and 6-[(18)F]-fluoro-l-DOPA (FDOPA) PET parameters. Nine physically and mentally healthy male men performed two FDOPA-PET scans including arterial plasma withdrawal. Over 3 days before the second scan, all subjects were treated with 5 mg/d haloperidol orally. Using our novel steady-state analysis, we calculated the intrinsic rate of the c…