Search results for "heartbeat"
showing 10 items of 39 documents
High blood pressure responders show largest increase in heartbeat perception accuracy after post-learning stress following a cardiac interoceptive le…
2020
Mental disorders with physical symptoms, e.g. somatic symptom disorder, are characterized by altered interoceptive accuracy (IAc), which can be explained by individual differences in interoceptive learning (IL). We investigated if stress facilitates IL. Seventy-three healthy participants performed a heartbeat counting task (HCT: T1) and a heartbeat perception training (HBPT). After exposure to a socially-evaluated cold pressor stress test (SECPT; n = 48) or a control condition (n = 25), two more HCTs were performed (T2: 30 min after SECPT; T3: 24 h later). After the HBPT, all participants showed an increase in IAc. We separated the stress group into high vs. low systolic blood pressures (SB…
Estimating brain load from the EEG.
2009
Modern work requires cognitively demanding multitasking and the need for sustained vigilance, which may result in work-related stress and may increase the possibility of human error. Objective methods for estimating cognitive overload and mental fatigue of the brain on-line, during work performance, are needed. We present a two-channel electroencephalography (EEG)–based index, theta Fz/alpha Pz ratio, potentially implementable into a compact wearable device. The index reacts to both acute external and cumulative internal load. The index increased with the number of tasks to be performed concurrently (p= 0.004) and with increased time awake, both after normal sleep (p= 0.002) and sleep restr…
Simultaneous recording of skin blood pulsations at different vascular depths by multiwavelength photoplethysmography.
2007
A new technique for parallel recording of reflection photoplethysmography (PPG) signals in a broad spectral band (violet to near-infrared) has been developed, and its potential for assessment of blood microcirculation at various depths from the skin surface is discussed. PPG signals have been simultaneously detected at cw laser wavelength sets comprising 405, 532, 645, 807, and 1064 nm. Various signal baseline responses to breath holding and different shapes of the PPG pulses originated from the same heartbeat but recorded at different wavelengths have been observed, indicating a depth variety of the skin blood pulsation dynamics.
Contact probe pressure effects in skin multi-spectral photoplethysmography
2007
A novel technique ensuring parallel recording of reflection photoplethysmography signals in broad spectral range has been tested for assessment of pressure-induced vascular changes at various depths from the skin surface. PPG signals have been simultaneously detected at three combinations of the cw laser wavelengths 405 nm, 532 nm, 645 nm, 807 nm and 1064 nm. The PPG baseline responses to the probe-skin contact pressure changes and shapes of the PPG pulses originated from the same heartbeat but recorded at different wavelengths have been detected and analyzed.
Multi-wavelength photoplethysmography for simultaneous recording of skin blood pulsations at different vascular depths
2007
Parallel recording of reflection photoplethysmography (PPG) signals in broad spectral band has been performed, and potential of this approach for assessment of blood microcirculation at various vascular depths is discussed. PPG signals have been simultaneously detected at cw laser wavelengths sets comprising 405 nm, 532 nm, 645 nm, 807 nm and 1064 nm. Different signal baseline responses to breath holding at different wavelengths have been observed, as well as different shapes of the PPG pulses originated from the same heartbeat.
Analysis of the effects of pulsed microwave on cardiac activity
1993
Abstract The exposure of isolated chick embryo hearts to 2.45 GHz pulse modulated microwaves has identified certain phenomena: (1) when the heartbeat was irregular, an appropriate pulse repetition rate caused regularization; (2) during regular beating, an increase of pulse repetition rate similarly increased the heartbeat frequency, until an irregular heartbeat appeared; (3) by applying microwaves, when an arrhythmia occurs, a regular beat appeared after a few seconds. Time correlation between the heartbeat and the modulating pulses revealed that regularization occurs when the modulation pulses, at a frequency close to the natural unperturbed heartbeat, were applied in the ventricular diast…
An improved non-invasive method for measuring heartbeat of intertidal animals
2013
Since its emergence two decades ago, the use of infrared technology for noninvasively measuring the heartbeat rates of invertebrates has provided valuable insight into the physiology and ecology of intertidal organisms. During that time period, the hardware needed for this method has been adapted to currently available electronic components, making the original published description obsolete. This article reviews the history of heartbeat sensing technology, and describes the design and function of a modern and simplified infrared heartbeat rate sensing system compatible with many intertidal and marine invertebrates. This technique overcomes drawbacks and obstacles encountered with previous …
Patient-Specific Analysis of Ascending Thoracic Aortic Aneurysm with the Living Heart Human Model
2021
In ascending thoracic aortic aneurysms (ATAAs), aneurysm kinematics are driven by ventricular traction occurring every heartbeat, increasing the stress level of dilated aortic wall. Aortic elongation due to heart motion and aortic length are emerging as potential indicators of adverse events in ATAAs
The interplay of interoceptive accuracy, facets of interoceptive sensibility, and trait anxiety: A network analysis
2021
Abstract Interoception is the sense of the body's physiological state. Both the ability to accurately perceive bodily signals, and the self-reported sensibility for the body were assumed to be reciprocally associated with negative affect. Up to now, the specific interplay between dimensions of interoception and negative affect remains largely unknown. We investigated the interplay of cardioceptive accuracy assessed by a heartbeat tracking task, facets of interoceptive sensibility as measured by the Multidimensional Assessment of Interoceptive Awareness, and trait anxiety as measured by the trait version of the State-Trait-Anxiety inventory across two studies (n = 243) using a network analyt…
Photoplethysmography Analysis of Artery Properties in Patients with Cardiovascular Diseases
2008
In this study arterial parameters of healthy subjects were compared to those of patients with cardiovascular diseases. The photoplethysmography (PPG) measurements of blood volume pulsations have been performed. Using a novel algorithm for analysis of simultaneously measured ear and finger PPG signals, arterial parameters were evaluated in representative groups of healthy subjects and patients with cardiovascular diseases. Digital volume pulse (DVP), pulse cycle duration (T), augmentation index (AIx), reflection index (RI) and transit time of reflected wave (RTT) were evaluated in every heartbeat cycle. Correlations between the AIx and RI, T and RTT, AIx and standard deviation of AIx, RTT an…