Search results for "high-frequency"
showing 10 items of 33 documents
Simple Lossless Inductive Snubbers-Assisted Series Load Resonant Inverter Operating under ZCS-PDM Scheme for High-Frequency Induction Heating Fixed R…
2022
This paper presents a high-frequency pulse-density-modulated (PDM) soft-switching series load resonant inverter for use in induction heating (IH) fixed roller applications, which is used in copy and printing machines. The proposed simple high-frequency resonant inverter uses an asymmetrical pulse pattern PDM control scheme to achieve complete zero-current soft-switching commutations over a wide output range of input power regulation. Additionally, when the printer toner requires operation in very light load conditions, this causes difficulty in achieving zero-voltage or zero-current soft-switching operations in the IH high-frequency resonant inverters with pulse frequency modulation or puls…
High-Speed Machines: Typologies, Standards, and Operation under PWM Supply
2018
This paper presents an overview of the most recent state of the art in the field of high-speed electric machines fed through high-frequency converters. This type of systems is rapidly wide spreading in aeronautical and automotive applications, as well as microturbines. Each typology has its own advantages and downsides, which are analytically presented in this paper. Some types of high-speed electric machines require high-frequency voltage supply, highly stressing the dielectric materials of the winding insulation system. For this reason, in high-speed electric drives, premature failure may occur and a reduction of the total system reliability has been observed in the past years. Such issue…
Independent right lung high frequency and left lung conventional ventilation in the management of severe air leak during ARDS
1995
Summary Pulmonary air leaks are one of the most common problems in patients with the adult respiratory distress syndrome, ARDS. We report what we believe to be the first case in which unilateral high-frequency ventilation combined with contralateral conventional positive pressure ventilation has been used successfully to manage severe air leak in an infant with ARDS.
Trading activity and price impact in parallel markets: SETS vs. off-book market at the London Stock Exchange
2011
We empirically study the trading activity in the electronic on-book segment and in the dealership off-book segment of the London Stock Exchange, investigating separately the trading of active market members and of other market participants which are non-members. We find that (i) the volume distribution of off-book transactions has a significantly fatter tail than the one of on-book transactions, (ii) groups of members and non-members can be classified in categories according to their trading profile (iii) there is a strong anticorrelation between the daily inventory variation of a market member due to the on-book market transactions and inventory variation due to the off-book market transac…
2006
Introduction The objective was to study the effects of a novel lung volume optimization procedure (LVOP) using highfrequency oscillatory ventilation (HFOV) upon gas exchange, the transpulmonary pressure (TPP), and hemodynamics in a porcine model of surfactant depletion. Methods With institutional review board approval, the hemodynamics, blood gas analysis, TPP, and pulmonary shunt fraction were obtained in six anesthetized pigs before and after saline lung lavage. Measurements were acquired during pressure-controlled ventilation (PCV) prior to and after lung damage, and during a LVOP with HFOV. The LVOP comprised a recruitment maneuver with a continuous distending pressure (CDP) of 45 mbar …
Initiation of high-frequency oscillatory ventilation and its effects upon cerebral circulation in pigs: an experimental study
2006
BACKGROUND: Current practice at high-frequency oscillatory ventilation (HFOV) initiation is a stepwise increase of the constant applied airway pressure to achieve lung recruitment. We hypothesized that HFOV would lead to more adverse cerebral haemodynamics than does pressure controlled ventilation (PCV) in the presence of experimental intracranial hypertension (IH) and acute lung injury (ALI) in pigs with similar mean airway pressure settings. METHODS: In 12 anesthetized pigs (24-27 kg) with IH and ALI, mean airway pressure (P(mean)) was increased (to 20, 25, 30 cm H(2)O every 30 min), either with HFOV or with PCV. The order of the two ventilatory modes (cross-over) was randomized. Mean art…
Multi-party metering: An architecture for privacy-preserving profiling schemes
2013
Several privacy concerns about the massive deploy- ment of smart meters have been arisen recently. Namely, it has been shown that the fine-grained temporal traces generated by these meters can be correlated with different users behaviors. A new architecture, called multi-party metering, for enabling privacy-preserving analysis of high-frequency metering data without requiring additional complexity at the smart meter side is here proposed. The idea is to allow multiple entities to get a share of the high-frequency metering data rather than the real data, where this share does not reveal any information about the real data. By aggregating the shares provided by different users and publishing …
Harmonic solution of semiconductor transport equations for microwave and millimetre-wave device modelling
2004
The transport equations for charges in a semiconductor have been solved for a periodic voltage excitation by means of a harmonic approach, for modelling of microwave and millimetre-wave active devices. The solution is based on the expansion of the unknown physical quantities in Fourier series in the time domain, and on the discretisation in the space domain. A Waveform-Balance technique in the time domain is used to solve the resulting non-linear equations system. In this way the time step is determined only by Nyquist's sampling requirements at the operating frequency, irrespective of the relaxation times of the semiconductor. This approach allows for a longer time step, and therefore a sh…
The Collinear Fast Beam laser Spectroscopy (Cfbs) experiment at Triumf
2016
Abstract Laser spectroscopy experiments at radioactive ion beam facilities around the world investigate properties of exotic nuclei for scientific endeavours such as, but not limited to, the investigation of nuclear structure. Advancements in experimental sensitivity and performance are continuously needed in order to extend the reach of nuclei that can be measured. The collinear fast beam laser spectroscopy ( Cfbs ) setup at Triumf , coupled to an out-of-plane radio-frequency quadrupole Paul trap, enables measurements of some of the most fundamental nuclear properties for long-lived ground and isomeric states. The first comprehensive overview of the Cfbs experiment is provided along with d…
Quantifying preferential trading in the e-MID interbank market
2015
Interbank markets allow credit institutions to exchange capital for purposes of liquidity management. These markets are among the most liquid markets in the financial system. However, liquidity of interbank markets dropped during the 2007-2008 financial crisis, and such a lack of liquidity influenced the entire economic system. In this paper, we analyze transaction data from the e-MID market which is the only electronic interbank market in the Euro Area and US, over a period of eleven years (1999-2009). We adapt a method developed to detect statistically validated links in a network, in order to reveal preferential trading in a directed network. Preferential trading between banks is detecte…