Search results for "holography"
showing 10 items of 210 documents
Stable and simple quantitative phase-contrast imaging by Fresnel biprism
2018
Digital holographic (DH) microscopy has grown into a powerful nondestructive technique for the real-time study of living cells including dynamic membrane changes and cell fluctuations in nanometer and sub-nanometer scales. The conventional DH microscopy configurations require a separately generated coherent reference wave that results in a low phase stability and a necessity to precisely adjust the intensity ratio between two overlapping beams. In this work, we present a compact, simple, and very stable common-path DH microscope, employing a self-referencing configuration. The microscope is implemented by a diode laser as the source and a Fresnel biprism for splitting and recombining the be…
Dual-mode holographic microscopy imaging platform
2018
We report on a novel layout capable of dual-mode imaging in real time with different magnifications and resolution capabilities in lensless microscopy. The concept is based on wavelength multiplexing for providing two illuminations with different wavefront curvatures: one is collimated, allowing a large field of view (FOV) with a poor resolution limit, and the other is divergent, to achieve a better resolution limit (micron range) over a small FOV. Moreover, our recently reported concept of MISHELF microscopy [M. Sanz, J. Á. Picazo-Bueno, L. Granero, J. García and V. Micó, Sci. Rep., 2017, 7, 43291] is applied to the divergent illumination case, improving the image quality by noise averagin…
Autostereoscopic Three-Dimensional Neuronavigation to the Sella: Technical Note.
2017
Background A drawback of conventional neuronavigation is the necessity of focusing on two-dimensional images in 3 planes at the same time to determine one's position in the operating field. A solution would be to merge the images into a single three-dimensional (3D) image that mirrors the actual anatomy. The introduction of holographic glassless 3D monitors paved the way to 3D navigation. We present our experience with 3D neuronavigation as exemplified by navigation to and within the sella. Methods Operative planning was conducted with a navigation system using cranial computed tomography and magnetic resonance imaging. The image data sets were processed by the prototype Clariti 3D system t…
<title>Holographic properties of dielectric crystals and amorphous semiconductor films</title>
2001
Holographic recording properties and mechanisms are analyzed and compared in dielectric electrooptic crystals (EOC), dielectric colored alkali halide crystals (AHC) and amorphous semiconductor films (ASF) basing on author's investigations as well as on the literature data. Holographic photosensitivity parameters are introduced enabling the characterization of the recording mechanism efficiency independently of the particular optical and geometrical sample parameters, and allowing also for recording optimization. Ultimate specific recording energies for EOC, AHC and ASF are theoretically estimated. It is concluded that the ultimate recording energy for both crystalline and amorphous material…
Lensless object scanning holography for two-dimensional mirror-like and diffuse reflective objects
2013
Recently proposed lensless object scanning holography (LOSH) [Opt. Express 20, 9382 (2012)] is a fully lensless method capable of improving the image quality in digital Fourier holography applied to one-dimensional (1D) reflective objects and it involves a very simplified experimental setup. LOSH is based on the recording and digital postprocessing of a set of digital lensless Fourier transform holograms, which finally results in a synthetic image with improved resolution, field-of-view (FOV), signal-to-noise ratio (SNR), and depth of field. In this paper, LOSH is extended to the cases of two-dimensional (2D) mirror-like and 1D diffuse-based objects. For 2D mirror-like objects, the experime…
2017
Abstract. In situ observations of cloud properties in complex alpine terrain where research aircraft cannot sample are commonly conducted at mountain-top research stations and limited to single-point measurements. The HoloGondel platform overcomes this limitation by using a cable car to obtain vertical profiles of the microphysical and meteorological cloud parameters. The main component of the HoloGondel platform is the HOLographic Imager for Microscopic Objects (HOLIMO 3G), which uses digital in-line holography to image cloud particles. Based on two-dimensional images the microphysical cloud parameters for the size range from small cloud particles to large precipitation particles are obtai…
In-line holography of cloud volumes applied to the measurement of raindrops and snowflakes
1998
Abstract The ground-based HODAR (HOlographic Droplet and Aerosol Recording) of the University of Mainz has been operational since 1989 on the Kleiner Feldberg Mountain Observatory near Frankfurt/Main, Germany, in a `small volume' configuration. With this setup an air volume of approximately 1 l can be in situ recorded, which allows it to image all aerosol particles and droplets with diameter larger than 6 μm contained in the sample volume in situ. Recently the beam diameter and optical path length of the inline system have been enlarged such that large cloud volumes (approximately 500 l) can be recorded on single holograms. During the holographic image reconstruction step in the laboratory,…
Holographic Observations of Centimeter-Scale Nonuniformities within Marine Stratocumulus Clouds
2020
Abstract Data collected with a holographic instrument [Holographic Detector for Clouds (HOLODEC)] on board the High-Performance Instrumented Airborne Platform for Environmental Research Gulfstream-V (HIAPER GV) aircraft from marine stratocumulus clouds during the Cloud System Evolution in the Trades (CSET) field project are examined for spatial uniformity. During one flight leg at 1190 m altitude, 1816 consecutive holograms were taken, which were approximately 40 m apart with individual hologram dimensions of 1.16 cm × 0.68 cm × 12.0 cm and with droplet concentrations of up to 500 cm−3. Unlike earlier studies, minimally intrusive data processing (e.g., bypassing calculation of number concen…
Search for Microphysical Signatures of Stochastic Condensation in Marine Boundary Layer Clouds Using Airborne Digital Holography
2019
2020
Abstract. An ice cloud chamber was developed at the Johannes Gutenberg University of Mainz for generating several thousand data points for mass and sedimentation velocity measurements of ice crystals with sizes less than 150 µm. Ice nucleation was initiated from a cloud of supercooled droplets by local cooling using a liquid nitrogen cold finger. Three-dimensional tracks of ice crystals falling through the slightly supersaturated environment were obtained from the reconstruction of sequential holographic images, automated detection of the crystals in the hologram reconstructions, and particle tracking. Through collection of the crystals and investigation under a microscope before and after …