Search results for "image"
showing 10 items of 6818 documents
Automatic detection of lung nodules in CT datasets based on stable 3D mass–spring models
2012
We propose a computer-aided detection (CAD) system which can detect small-sized (from 3 mm) pulmonary nodules in spiral CT scans. A pulmonary nodule is a small lesion in the lungs, round-shaped (parenchymal nodule) or worm-shaped (juxtapleural nodule). Both kinds of lesions have a radio-density greater than lung parenchyma, thus appearing white on the images. Lung nodules might indicate a lung cancer and their early stage detection arguably improves the patient survival rate. CT is considered to be the most accurate imaging modality for nodule detection. However, the large amount of data per examination makes the full analysis difficult, leading to omission of nodules by the radiologist. We…
A CAD system for nodule detection in low-dose lung CTs based on region growing and a new active contour model
2007
A computer-aided detection (CAD) system for the selection of lung nodules in computer tomography (CT) images is presented. The system is based on region growing (RG) algorithms and a new active contour model (ACM), implementing a local convex hull, able to draw the correct contour of the lung parenchyma and to include the pleural nodules. The CAD consists of three steps: (1) the lung parenchymal volume is segmented by means of a RG algorithm; the pleural nodules are included through the new ACM technique; (2) a RG algorithm is iteratively applied to the previously segmented volume in order to detect the candidate nodules; (3) a double-threshold cut and a neural network are applied to reduce…
Hybrid segmentation and exploration of the human lungs
2004
Segmentation of the tracheo-bronchial tree of the lungs is notoriously difficult. This is due to the fact that the small size of some of the anatomical structures is subject to partial volume effects. Furthermore, the limited intensity contrast between the participating materials (air, blood, and tissue) increases the segmentation of difficulties. In this paper, we propose a hybrid segmentation method which is based on a pipeline of three segmentation stages to extract the lower airways down to the seventh generation of the bronchi. User interaction is limited to the specification of a seed point inside the easily detectable trachea at the upper end of the lower airways. Similarly, the comp…
Impact of an intensive education programme of diagnostic lung and lower limb ultrasound on physiotherapist knowledge: A pilot study.
2021
INTRODUCTION/PURPOSE: Diagnostic ultrasound of the respiratory system and peripheral muscular systems is increasingly being used by clinicians. The aim of this study was to evaluate the knowledge outcomes of a bespoke one‐day curriculum for physiotherapists that incorporated lung, diaphragm and lower limb muscle diagnostic ultrasound theory and practical training in image acquisition and analysis. METHODS: A one‐day course comprised of three instructors and 32 participants on key diagnostic ultrasound findings of the lungs, diaphragm and lower limb musculature included didactic lectures combined with expert‐led hands‐on training in practical sessions. Participants undertook pre‐ and post‐co…
Undetected Malignancies of the Breast: Dynamic Contrast-enhanced MR Imaging at 1.0 T
2002
To assess the prevalence and characteristics of malignant breast lesions not identified with magnetic resonance (MR) imaging.Breast tissue specimens were obtained in 464 of 967 patients who had undergone dynamic gadolinium-enhanced T1-weighted fast low-angle shot three-dimensional MR imaging of both breasts. A comparison of sensitivity, specificity, and predictive values of the prospectively recorded findings of mammography, ultrasonography (US), and MR imaging with the histopathologic results was performed with receiver operating characteristic (ROC) curve analysis. MR imaging examination findings that caused a false-negative diagnosis were reviewed to identify possible sources of error.Hi…
Graph-matching based CTA.
2009
Separating bone, calcification, and vessels in computer tomography angiography (CTA) allows for a detailed diagnosis of vessel stenosis. This paper presents a new, graph-based technique that solves this difficult problem with high accuracy. The approach requires one native data set and one that is contrast enhanced. On each data set, an attributed level-graph is derived and both graphs are matched by dynamic programming to differentiate between bone, on one hand side, and vessel/calcification on the other hand side. Lumen and calcified regions are then separated by a profile technique. Evaluation is based on data from vessels of pelvis and lower extremities of elderly patients. Due to subst…
Diffuse reflectance and fluorescence multispectral imaging system for assessment of skin
2014
The diffuse reflectance multispectral imaging technique has been used for distant mapping of in vivo skin chromophores (hemoglobin and melanin). The fluorescence multispectral imaging is not so common for skin applications due to complicity of data acquisition and processing, but could provide additional information about skin fluorophores. Both techniques are compatible, and could be combined into a multimodal solution. The multispectral imaging system Nuance based on liquid crystal tunable filters was adapted for diffuse reflectance and fluorescence spectral imaging of in vivo skin. Uniform illumination was achieved by LED ring light. Combination of four LEDs (warm white, 770 nm, 830 nm a…
Skin haemoglobin mapping: comparison of multi-spectral imaging and selective R-G-B analysis
2010
The multi-spectral imaging technique has been used for distant mapping of in-vivo skin haemoglobin. Besides, potential of selective R-G-B analysis of skin images has been studied under bi-chromatic (532 nm and 635 nm) laser illumination.
Optical quality of intraocular lenses after several years in the human eye
2013
The optical quality of explanted intraocular lenses (IOLs) was analysed to verify if their quality is maintained after having been in the human eye for several years. Twenty-five explanted IOLs were studied, 10 because of intraocular luxation and 15 from corneal donors. The dioptric power and modulation transfer function (MTF) were determined to discover the image quality of the IOLs. The spectral transmission was also established to ascertain whether the filter against ultraviolet (UV) radiation was still effective. The results show that the MTF of implanted IOLs is maintained and therefore so is the image quality they provide. Only decay in the MTF of some of the explanted IOLs was observ…
Influence of the tear film on optical quality of the eye
1997
The optical quality of the tear film of the eye was tested by measuring the retinal image before and after the break-up time (BUT). An objective method was used based on the evaluation of the retinal image of a point test projected onto the fovea. The loss of an entire tear film would result in a decrease in the optical quality because of corneal irregularities and the formation of an irregular tear lens after the BUT. Our results confirm the expected loss both of non-contact lens wearers and contact lens wearers. Also, the fact that the optical deterioration found after the BUT is greater for contact lens wearers confirms that soft contact lens wear produces a disruption of the tears.