Search results for "implants"
showing 10 items of 505 documents
Diffractive corneal inlay for presbyopia
2017
[EN] A conceptually new type of corneal inlays for a customized treatment of presbyopia is presented. The diffractive inlay consists on a small aperture disc having an array of micro-holes distributed inside the open zones of a Fresnel zone plate. In this way, the central hole of the disc lets pass the zero order diffraction and produces an extension of the depth of far focus of the eye, while the diffracted light through the holes in the periphery produce the near focus. Additionally, the micro-holes in the inlay surface fulfill the essential requirement of allowing the flow of nutrients through it to the cells of the corneal stroma. Theoretical and optical-bench experimental results for t…
Post extractive implant: evaluation of the critical aspects
2017
Purpose Nowadays, implant supported prosthetic rehabilitation is a reliable procedure to replace compromised or untreatable teeth. The purpose of this review is to explore the concept of post extractive implant and the indications for clinical practice through an analysis of recent studies in the literature. All the main factors that could influence the outcome of this treatment will also be considered. Materials and methods Focusing on the extraction-socket healing time, three different implant insertion protocols have been defined: Immediate implant placement (IIP), Early implant placement (EIP), Delayed implant placement (DIP). The entity of bone remodeling can be associated with differe…
Exposed Subcutaneous Implantable Devices
2015
Background: Implantable venous and electrical devices are prone to exposure and infection. Indications for management are controversial, but—especially if infected—exposed devices are often removed and an additional operation is needed to replace the device, causing a delay in chemotherapy and prolonging healing time. We present our protocol for device salvage, on which limited literature is available. Methods: Between 2007 and 2013, 17 patients were treated (12 venous access ports, 3 cardiac pacemakers, and 2 subcutaneous neural stimulators). Most patients were operated within 7 days from exposure. All patients received only a single perioperative dose of prophylactic antibiotic. In cases …
Complement proteins regulating macrophage polarisation on biomaterials
2019
[EN] One of the events occurring when a biomaterial is implanted in an host is the protein deposition onto its surface, which might regulate cell responses. When a biomaterial displays a compromised biocompatibility, distinct complement pathways can be activated to produce a foreign body reaction. In this article, we have designed different types of biomaterial surfaces to study the inflammation process. Here, we used different concentrations of (3-glycidoxypropyl)-trimethoxysilane (GPTMS), an organically-modified alkoxysilane as a precursor for the synthesis of various types of sol-gel materials functionalizing coatings for titanium implants to regulate biological responses. Our results sh…
Multiple teeth replacement with endosseous one-piece yttrium-stabilized zirconia dental implants
2012
Objectives: The purpose of this study is to clinically and radiographically evaluate survival and success rate of multiple zirconia dental implants positioned in each patient during a follow-up period of at least 12 months up to 48 months. Study Design: Eight patients were treated for multiple edentulism with 29 zirconia dental implants. All implants received immediate temporary restorations and 6 months after surgery were definitively restored. 6 months to 4 years after implant insertion, a clinical-radiographic evaluation was performed in order to estimate peri-implant tissues health and peri-implant marginal bone loss. Results: Survival rate within follow-up period was therefore 100%. Th…
Lowering of the mouth floor and vestibuloplasty to support a mandibular overdenture retained by two implants. A case report
2014
In Oral Implantology most of the procedures are predictable and have high success rates. The use of osseointegrated implants as a therapeutic option for the rehabilitation of patients with severe mandibular atrophy has decreased the need for pre-prosthetic surgery Nevertheless, complications may occur during implant surgery and also once the prosthesis has been placed. This paper describes the case of a totally edentulous patient with an upper complete removable denture and an implant-retained overdenture with two implants in the intermentonian region. During clinical examination, the implant abutments were totally covered by soft tissue since the floor of the mouth was elevated. The panora…
One-year implant survival following lateral window sinus augmentation using plasma rich in growth factors (PRGF) : a retrospective study
2019
Background The aim of this study was to assess one-year implant survival after lateral window sinus augmentation using PRGF combined with various bone grafting materials. Material and Methods This was a retrospective chart review and radiographic analysis of patients that had undergone lateral window sinus augmentation with PRGF and had dental implants placed at least 6 months post augmentation. All implants included were followed up for at least one year after placement. Demographic, sinus and implant related characteristics (residual ridge height, sinus membrane perforation, type of graft material, implant length and width and ISQ at placement) were analyzed. Results A total of 31 patient…
Small-diameter titanium Grade IV and titanium-zirconium implants in edentulous mandibles: three-year results from a double-blind, randomized controll…
2015
OBJECTIVE: The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures. MATERIALS AND METHODS: This was a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann bone-level implants (diameter 3.3 mm), one of Ti Grade IV (control) and one of TiZr (test), in the interforaminal region. Implants were loaded after 6-8 weeks and removable Locator-retained overdentures were placed within 2 weeks of l…
Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: five-year results from a double-blind, randomized controlle…
2015
BACKGROUND The aim of this study was to compare the 5-year survival and success rates of 3.3 mm dental implants either made from titanium-zirconium (TiZr) alloy or from Grade IV titanium (Ti Grade IV) in mandibular implant-based removable overdentures. METHODS The core study had a follow-up period of 36 months and was designed as a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann Bone Level implants (diameter 3.3 mm, SLActive®), one of TiZr (test) and one of Ti Grade IV (control), in the interforaminal region. This follow-up study recruited patients from the core study and evaluated the plaque and sulcus …
Biologic response of inguinal hernia prosthetics: a comparative study of conventional static meshes versus 3D dynamic implants.
2015
Despite improvements in prosthetics and surgical techniques, the rate of complications following inguinal hernia repair remains high. Among these, discomfort and chronic pain have become a source of increasing concern among surgeons. Poor quality of tissue ingrowth, such as thin scar plates or shrinking scars-typical results with conventional static implants and plugs-may contribute to these adverse events. Recently, a new type of 3D dynamically responsive implant was introduced to the market. This device, designed to be placed fixation-free, seems to induce ingrowth of viable and structured tissue instead of regressive fibrotic scarring. To elucidate the differences in biologic response be…