Implants in patients with oral manifestations of autoimmune or muco-cutaneous diseases – A systematic review
2018
Background To give an overview on implant survival rates in patients with oral manifestations of systemic autoimmune (oral Lichen planus (oLp), Pemphigus (Pe)), muco-cutaneous (Epidermolysis bullosa (EB)), autoimmune multisystemic rheumatic diseases (Sjögren´s syndrome (SjS), systemic Lupus erythematosus (sLE), or systemic Sclerosis (sSc)). Material and Methods Systematic literature review (PubMed/Medline, Embase) using MESH and search term combinations, published between 1980 and August 2018 in English language reporting on dental implant-prosthetic rehabilitation of patients with oLp, Pe, EB, SjS, sLE, sSc, study design, age, gender, follow-up period (≥ 12 months), implant survival rate. …
Clinical and logopaedic results of simultaneous and sequential bilateral implants in children with severe and/or profound bilateral sensorineural hea…
2015
This article carries out a literature review of the advantages and limitations of the simultaneous bilateral cochlear implantation (SCI) compared to those of the sequential bilateral cochlear implantation (SBCI) and the unilateral cochlear implantation (UCI). The variables analysed in said comparison are: safety and surgical technique, SCI incidence, effectiveness, impact of the inter-implant interval, costs and financing, impact on brain plasticity, impact on speech and language development, main benefits, main disadvantages and concerns, and predictive factors of prognosis. Although the results are not conclusive, all variables analysed seem to point towards observable benefits of SCI in …
Prosthetic strap system for simplified ventral hernia repair. Its results in a porcine experimental model.
2010
Abstract: Introduction Aiming to achieve a simplified ventral hernia repair, a proprietary shaped mesh was experimentally tested in the porcine model. The mesh is structured with a large central body and radiating straps. The friction of the straps passing through the tissues are hypothesized to be adequate to maintain the mesh in place during tissue ingrowth, avoiding classic point fixation while ensuring a wide coverage of the abdomen. Methods The mesh, having 6 radial straps, was placed using a sublay preperitoneal technique in 4 pigs. All straps were passed laterally through the abdominal wall and exteriorized from the skin. The straps were trimmed at the level of the skin, allowing the…
Nickel release after implantation of the Amplatzer occluder.
2003
Background Transcatheter closure of atrial septal defects is a new and less traumatic technique than open heart surgery. In recent years, patients with a patent foramen ovale sustaining potential paradoxical embolism have also become candidates for interventional closure devices. One of the more popular occluding devices is the Amplatzer septal occluder, which, like many other occluders, is made of nitinol. Nitinol-based alloys are widely used in medical products, for example, in orthopedics and orthodontics. However, the clinical use of nitinol, which contains 55% nickel, is still controversial because of concerns about its biocompatibility. Therefore, we examined the systemic nickel relea…
Resonance frequency analysis-reliability in third generation instruments : Osstell mentor ®
2012
Few studies assess repeatability and reproducibility in registers of resonance frequency analysis (a value of dental implant stability). Objective: Few studies assess repeatability and reproducibility in resonance frequency analyses (implant stability evaluation). This study is aimed at assessing reliability (repeatabilty and reproducibility) in the Osstell Mentor® system using the intraclass correlation coefficient (ICC) as the statistical method. Study Design: ISQ measurements of RFA were carried out by means of the Osstell Mentor ® instrument in 58 implants in 19 patients. Six measurements were performed on each implant by means of two different Smart-Pegs (I and II). Three consecutive m…
Histopathologic Findings in Early Encapsulated Blebs of Young Patients Treated With the Ahmed Glaucoma Valve
2010
Objective/aim Uncontrolled glaucoma presents a challenge for the ophthalmic surgeon especially in children and juvenile patients. For many patients who have undergone failed surgical procedures before, episcleral implants remain the last choice. Encapsulated blebs forming over antiglaucoma devices present a complication leading to malfunctioning or even failure with reincrease in intraocular pressure. We report our histopathologic findings of such blebs developing around the Ahmed glaucoma valve (AGV) after a short time period in young patients. Materials and methods Nine young patients (2 to 17 y of age) with otherwise uncontrollable glaucoma were treated with AGV (models FP-7 and FP-8, si…
Fluocinolone acetonide vitreous insert for chronic diabetic macular oedema: a systematic review with meta-analysis of real-world experience
2021
AbstractWe conducted a meta-analysis of real-world studies on the 0.19 mg Fluocinolone Acetonide (FAc) intravitreal implant for chronic diabetic macular oedema (DMO), comparing these findings with the Fluocinolone Acetonide for Diabetic Macular Edema (FAME) study. The primary outcome was mean change of best corrected visual acuity (BCVA) at 24 months. Secondary outcomes were 36-month mean BCVA, mean central macular thickness (CMT) change, rates of eyes receiving supplementary intravitreal therapy, cataract surgery, intraocular pressure (IOP)-lowering drops and glaucoma surgery. Mean differences (MDs) with 95% confidence intervals (CIs) were calculated. Nine real-world studies were included.…
Current Status of Epibulbar Anti-glaucoma Drainage Devices in Glaucoma Surgery
2012
SUMMARY Background: The term “glaucoma” covers a hetero geneous group of progressive optic neuropathies that are accompanied by characteristic visual-field defects. Primary open-angle glaucoma, the most common type, progresses insidiously and causes blindness if untreated. All current forms of treatment aim at lowering the intraocular pressure (IOP) in patients whose IOP is elevated. The implantation of anti-glaucoma drainage systems is one of the available options for surgical treatment. Methods: This review is based on pertinent literature retrieved by a selective search, including glaucoma treatment guidelines from Germany and abroad. Results: A paradigm shift is currently underway regar…
Narrow-diameter implants: Are they a predictable treatment option? A literature review
2013
Objective: To evaluate the predictability of narrow-diameter implants as a treatment option in routine clinical practice. A literature review was performed of studies reporting clinical results obtained with these implants. Survival rates, peri-implant bone loss and related complications were evaluated. The working hypothesis was that narrow-diameter implants offer clinical results similar to those obtained with implants of greater diameter. Material and Methods: A Medline-PubMed search covering the period between 2002 and 2012 was carried out. Studies published in English and with a follow-up period of at least 12 months were considered for inclusion. A manual search was also conducted in …
Spring constants of capsular tension rings.
2004
Purpose To determine the spring constants of several types of capsular tension rings (CTRs). Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods Fourteen models of CTRs provided by 9 companies were tested; all were 11.0 mm in diameter. The CTRs were positioned in a special retainer of a material-testing machine and compressed at a constant speed of 10.0 mm per minute. The distance and force values were recorded, and each CTR model was tested 3 times using a new specimen each time. The resulting measurements were used to calculate a mean spring constant for each CTR model. Results All tested CTRs showed linear proportionality between force and compress…